NAVY UFGS-07 31 13-2011 ASPHALT SHINGLES《沥青瓦》.pdf
《NAVY UFGS-07 31 13-2011 ASPHALT SHINGLES《沥青瓦》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-07 31 13-2011 ASPHALT SHINGLES《沥青瓦》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 31 13 (November 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 31 13 (May 2011)UFGS-07 31 13 (April 2006)UFGS-07311 (February 2003)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2011*SECTION TABLE OF CONTENTSDIV
2、ISION 07 - THERMAL AND MOISTURE PROTECTIONSECTION 07 31 13ASPHALT SHINGLES11/11PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.2.1 Top Lap1.2.2 Head Lap1.2.3 Exposure1.3 SUBMITTALS1.4 DELIVERY AND STORAGE1.5 WARRANTIES1.5.1 Manufacturers Warranty1.5.2 Contractors Warranty1.6 QUALITY ASSURANCE1.6.1 Loca
3、l/Regional Materials1.6.2 Recycled MaterialsPART 2 PRODUCTS2.1 MATERIALS2.1.1 Shingles2.1.2 Mineral-Surfaced Asphalt Roll Roofing2.1.3 Smooth-Surfaced Asphalt Roll Roofing2.1.4 Underlayment2.1.4.1 Leak Barrier Underlayment2.1.5 Self-Adhering Membrane2.1.6 Nails for Applying Shingles and Asphalt-Satu
4、rated Felt2.1.7 Asphalt Roof Cement2.1.8 Asphalt Primer2.1.9 Ventilators2.1.9.1 Nailable Plastic Shingle Over Type Ridge Vents2.1.9.2 Nailable Mesh Shingle Over Type Ridge VentsPART 3 EXECUTIONSECTION 07 31 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license
5、 from IHS-,-,-3.1 VERIFICATION OF CONDITIONS3.2 SURFACE PREPARATION3.3 APPLICATION3.3.1 Underlayment3.3.2 Drip Edges3.3.3 Starter Strip3.3.4 Shingle Courses3.3.5 Hips and Ridges3.3.6 Valleys3.3.6.1 Closed Cut Valleys3.3.6.2 Woven Valleys3.3.6.3 Open Roll Roofing Valleys3.3.6.4 Open Sheet Metal Valle
6、ys3.3.7 Flashing3.3.7.1 Eave Flashing3.3.7.2 Stepped Flashing3.3.7.3 Vent and Stack Flashing3.3.7.4 Chimney Flashing- End of Section Table of Contents -SECTION 07 31 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA /
7、NASA UFGS-07 31 13 (November 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 31 13 (May 2011)UFGS-07 31 13 (April 2006)UFGS-07311 (February 2003)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2011*SECTION 07 31 13ASPHALT SHINGLES11/11*NOTE: This guide
8、specification covers the requirements for asphalt shingle roofing, surfaced with mineral granules, including roofing felt, ridge vents, underlayments, and flashings.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparin
9、g new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, wheth
10、er or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: For a more detailed description of asphalt shingle roofing and requirements for asphalt shingle reroofing over exist
11、ing asphalt shingles, wood shingles, roll roofing, or built-up roofing, see the “Residential Asphalt Roofing Manual,“ published by Asphalt Roofing Manufacturers Association (ARMA) and “The NRCA Steep Roofing Manual,“ published by the National Roofing Contractors Association (NRCA). Avoid reroofing w
12、ith asphalt shingles over more than one layer of existing roofing material.*NOTE: On the drawings, show:SECTION 07 31 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1. Pitch of substrate/shingle roofing2. Detail of crickets and flashings at
13、 chimneys3. Detail at eave/rake corner of roof including underlayment, drip edge, starter strip, shingle exposure, shingle courses, and fastener placement.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publication
14、s are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Arti
15、cle. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form
16、a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM D 226/D 226M (2009) Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and WaterproofingASTM D 3018/D 3018M (2011
17、) Standard Specification for Class A Asphalt Shingles Surfaced With Mineral GranulesASTM D 3462/D 3462M (2010a) Standard Specification for Asphalt Shingles Made From Glass Felt and Surfaced with Mineral GranulesASTM D 4586 (2007) Asphalt Roof Cement, Asbestos-FreeASTM D 6380 (2003; R 2009) Standard
18、Specification for Asphalt Roll Roofing (Organic Felt)ASTM D1970/D1970M (2011) Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep SECTION 07 31 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Roofing Underlayment for Ice
19、Dam ProtectionASTM D3161 (2009) Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method)ASTM D41/D41M (2011) Asphalt Primer Used in Roofing, Dampproofing, and WaterproofingASTM D4869/D4869M (2005e1; R 2011) Standard Specification for Asphalt-Saturated Organic Felt Underlayme
20、nt Used in Steep Slope RoofingNATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA)NRCA 0418 (2009) Steep-slope Roof System ManualU.S. GREEN BUILDING COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction (LEED-NC)UNDERWRITERS
21、 LABORATORIES (UL)UL 2218 (2010) UL Standard for Safety Impact Resistance of Prepared Roof Covering MaterialsRef TitleUL 790 (2004; Reprint Oct 2008) Standard Test Methods for Fire Tests of Roof Coverings1.2 DEFINITIONS1.2.1 Top LapThat portion of shingle overlapping shingle in course below.1.2.2 He
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0731132011ASPHALTSHINGLES 沥青 PDF