NAVY UFGS-07 11 13-2011 BITUMINOUS DAMPPROOFING《含沥青的防潮处理》.pdf
《NAVY UFGS-07 11 13-2011 BITUMINOUS DAMPPROOFING《含沥青的防潮处理》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-07 11 13-2011 BITUMINOUS DAMPPROOFING《含沥青的防潮处理》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 11 13 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 11 13 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 07 - THERMAL AND MOISTURE PROTECTIONSECTION 07 1
2、1 13BITUMINOUS DAMPPROOFING08/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY AND STORAGE1.4 SAFETY AND HEALTH REQUIREMENTSPART 2 PRODUCTS2.1 ASPHALT2.2 ASPHALT PRIMER2.3 CREOSOTE PRIMER2.4 COAL-TAR PITCH2.5 FIBROUS ASPHALT2.6 EMULSION-BASED ASPHALT DAMPPROOFING2.6.1 Fibrated Emulsion-Based
3、 Asphalt2.6.2 Non-Fibrated Emulsion-Based Asphalt2.7 SURFACE PROTECTION2.7.1 Saturated Felt2.7.2 Protection BoardPART 3 EXECUTION3.1 SURFACE PREPARATION3.1.1 Metal Surfaces3.2 Protection of Surrounding Areas3.3 APPLICATION3.3.1 Surface Priming3.3.2 Hot-Application Method3.3.3 Cold-Application Method
4、3.3.3.1 Fibrous Asphalt3.3.3.2 Emulsion-Based Asphalt3.4 PROTECTIVE COVERING- End of Section Table of Contents -SECTION 07 11 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SECTION 07 11 13 Page 2Provided by IHSNot for ResaleNo reproduction
5、 or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-07 11 13 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 11 13 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 07 11 13BITUMINOUS D
6、AMPPROOFING08/11*NOTE: This guide specification covers the requirements for bituminous dampproofing to resist passage of moisture/water in the absence of hydrostatic pressure. It is intended to be used where protection is required against ingress of water by capillary action resulting from occasiona
7、l exposure to moisture or where reduced transfer of water vapor through the surface is necessary. Use of bituminous dampproofing should be considered for conditions such as the following:1. Exterior side of exterior concrete or masonry walls enclosing occupied spaces below grade where a head of wate
8、r or unusually wet soil conditions are not present (use Section 07 12 00, BUILT-UP BITUMINOUS WATERPROOFING when head of water exists).2. Backside of concrete or masonry retaining walls and stone facing where percolating of water through the wall or facing would produce objectionable staining.3. Ins
9、ide surface of single wythe, exterior, furred concrete or masonry walls above grade where reduction of transfer of water vapor through the wall is necessary.4. Cavity face of interior wythe of masonry cavity walls.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard
10、when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requi
11、rements not required in SECTION 07 11 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should b
12、e submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, design
13、ation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in
14、 the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by t
15、he basic designation only.ASTM INTERNATIONAL (ASTM)ASTM C208 (2008a) Cellulosic Fiber Insulating BoardASTM C728 (2005; R 2010) Perlite Thermal Insulation BoardASTM D 1227 (1995; R 2007) Emulsified Asphalt Used as a Protective Coating for RoofingASTM D 226/D 226M (2009) Standard Specification for Asp
16、halt-Saturated Organic Felt Used in Roofing and WaterproofingASTM D 227 (2003) Coal-Tar-Saturated Organic Felt Used in Roofing and WaterproofingASTM D 4263 (1983; R 2005) Indicating Moisture in Concrete by the Plastic Sheet MethodASTM D 43 (2000; R 2006) Coal Tar Primer Used in Roofing, Dampproofing
17、, and WaterproofingSECTION 07 11 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM D 4479 (2007) Asphalt Roof Coatings - Asbestos-FreeASTM D 449 (2003; R 2008) Asphalt Used in Dampproofing and WaterproofingASTM D 450 (2007) Coal-Tar Pitch
18、 Used in Roofing, Dampproofing, and WaterproofingASTM D1187/D1187M (2011) Asphalt-Base Emulsions for Use as Protective Coatings for MetalASTM D41/D41M (2011) Asphalt Primer Used in Roofing, Dampproofing, and WaterproofingU.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)29 CFR 1926 Safety and
19、Health Regulations for Construction1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality c
20、ontrol.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0711132011BITUMINOUSDAMPPROOFING 沥青 防潮 处理 PDF

链接地址:http://www.mydoc123.com/p-984715.html