NAVY MIL-F-24402 E (2)-1995 FILTER (HYDRAULIC) FILTER ELEMENTS (HIGH EFFICIENCY) AND FILTER DIFFERENTIAL PRESSURE INDICATORS GENERAL SPECIFICATION FOR《过滤器(水压的)过滤元件和过滤差压指示计总说明书》.pdf
《NAVY MIL-F-24402 E (2)-1995 FILTER (HYDRAULIC) FILTER ELEMENTS (HIGH EFFICIENCY) AND FILTER DIFFERENTIAL PRESSURE INDICATORS GENERAL SPECIFICATION FOR《过滤器(水压的)过滤元件和过滤差压指示计总说明书》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-F-24402 E (2)-1995 FILTER (HYDRAULIC) FILTER ELEMENTS (HIGH EFFICIENCY) AND FILTER DIFFERENTIAL PRESSURE INDICATORS GENERAL SPECIFICATION FOR《过滤器(水压的)过滤元件和过滤差压指示计总说明书》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-F-24402E(SH)AMENDMENT 226 May 1995SUPERSEDINGAMENDMENT 17 July 1992MILITARY SPECIFICATIONFILTER (HYDRAULIC), FILTER ELEMENTS (HIGH EFFICIENCY), ANDFILTER DIFFERENTIAL PRESSURE INDICATORS,GENERAL SPECIFICATION FORThis amendment forms a part of MIL-F-24402E(SH), Dated 3 April 1990, and isapproved
2、for use by the Naval Sea Systems Command, Department of the Navy and isavailable for use by all Department and Agencies of the Department of Defense.PAGE 2Add the following specifications to the Military Specifications Listing:MIL-F-24704 - Flanges, Four Bolt Square, Hydraulic, General Specification
3、 for.MIL-F-24704/4 - Flanges, Four Bolt Square, Blind For Hydraulic Systems.MIL-F-24704/5 - Flanges, Four Bolt, Insert Sleeves For Hydraulic Systems.PAGE 3* Add the following standard to the American Society For Testing And Materials(ASTM) :A 342 - Standard Test Methods for Permeability of Feebly Ma
4、gnetic Materials.PAGE 4* 3.4: Add the following:“ The aluminum parts of the filter elements are exempted from anodizingrequirements. Plated socket head cap screws shall not be utilized”.AMSC FSC 4330DISTRIBUTION STATEMENT A. Approved for public release: distribution is unlimited.1 of 4Provided by IH
5、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-24402E(SH)AMENDMENT 2PAGE 4* Add the following new paragraph:“3.3.4 Filter element magnetic permeability. The size B and size C filterelements shall have a relative magnetic permeability of less than 2.0 when t
6、estedin accordance with ASTM-A432.“PAGE 53.4.2.1, Line 5: Delete “ housings “ and substitute “housing bowls“.PAGE 93.6.3: Delete item “(d)“ in its entirety.PAGE 11Table I:(a). Delete footnote from the check valve leakage test.* (b). Add the following test after “Examination“ under “Element no. 1“:PA
7、GE 15Table II, Sampling: Delete “Pressure point “ and substitute “Clean elementpressure drop 3J.Table II, Footnote : Delete and substitutespecified in 4.5.1 do not apply. For leakagefluid, an increased leakage is permitted onlyqualifying activity.“Fluid, temperature, and viscositytests with other th
8、an MIL-L-17331when specifically approved by the4.4.2 Delete “and 4.4.2.2“ and substitute “through 4.4.2.3“.4.4.2.1 and 4.4.2.2: Delete and add the following paragraphs.2 of 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-24402E(SH)AMENDMENT 2“
9、4.4.2.1 Sampling for examination and tests. For the purpose of sampling,filter elements shall be grouped into lots not exceeding 501 pieces. A lot isdefined as elements produced at one facility, fabricated by the same process,which are of same material, size, type and part number.“4.4.2.2 Examinatio
10、n and bubble point test. As a minimum the manufacturershall select a sample quantity from each lot of filter elements in accordancewith table III and inspect them in accordance with table II. If one or moredefectes are found in any sample, the entire lot shall be rejected. Themanufacturer has the op
11、tion of screening 1002 of the rejected lot for thedefective characteristic(s) or providing a new lot which shall be inspected inaccordance with the sampling plan contained herein.“4.4.2.3 Clean element pressure drop test. As a minimum the manufacturer shallselect a sample quantity from each lot of f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILF24402E21995FILTERHYDRAULICFILTERELEMENTSHIGHEFFICIENCYANDFILTERDIFFERENTIALPRESSUREINDICATORSGENERALSPECIFICATIONFOR

链接地址:http://www.mydoc123.com/p-979137.html