NAVY MIL-DTL-24643 28 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS1S50MU (INCLUDING VARIATION LS1S50MUS)《LS1S50MU 型-20 ℃~+90 ℃电缆(包括变化型 LS1S50MUS)型》.pdf
《NAVY MIL-DTL-24643 28 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS1S50MU (INCLUDING VARIATION LS1S50MUS)《LS1S50MU 型-20 ℃~+90 ℃电缆(包括变化型 LS1S50MUS)型》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24643 28 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS1S50MU (INCLUDING VARIATION LS1S50MUS)《LS1S50MU 型-20 ℃~+90 ℃电缆(包括变化型 LS1S50MUS)型》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-24643/28F 1 October 2009 SUPERSEDING MIL-DTL-24643/28E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS1S50MU (INCLUDING VARIATION LS1S50MUS) This specification is approved for use by all Departments and Agencies of the Department of Defense. T
2、he requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24643. This cable can be manufactured in two variations: LS1S50MU and LS1S50MUS (double overall shield). Construction, Non-Watertight First - Copper conductor, tin-coated, ASTM B286, Size
3、 22 7strands. Second - Separator may be used at manufacturers option where required to provide free-stripping insulation. Third - Thermoset insulation, white. Nominal wall thickness of 0.030 inch; wall thickness may vary from nominal as necessary, in order for completed cable to meet the specified e
4、lectrical requirements. Fourth - Braided shield of 36 AWG, tin-coated copper. Braid angle of 20 to 25 degrees; minimum coverage of 90 percent. Fifth - Shield insulation of two polyester tapes, outer tape sealed. An alternate shield insulation may consist of one polyester tape plus an extruded jacket
5、 of a suitable transparent material, minimum average thickness of the transparent material 0.003 inch. The standard identification code shall be applied by Method 2 on the inner tape. Sixth - The required number of singles (see table I or II) cabled with a lay in accordance with 3.4.4 of MIL-DTL-246
6、43. Cabling sequence shall be consecutive, starting with no. 1. in the center outward. Fillers may be used as necessary to make a firm, well-rounded assembly. Seventh - An optional binder. Construction, Variant for Type LS1S50MU Eighth - Cross-linked polyolefin jacket. Minimum average wall thickness
7、 0.050 inch. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/28F Construction, Variant for Type LS1S50MUS Eighth - Braided shield of tin-coated copper with a minimum coverage of 85 percent. Ninth - Spirally wrapped 0.0
8、02-inch thick polyethylene (polyester film) separator tape with 25 percent minimum lap. Tenth - Braided shield of tin-coated copper with a minimum coverage of 85 percent. Eleventh - Cross-linked polyolefin jacket. Minimum average wall thickness 0.050 inch. TABLE I. Details (unshielded). Overall diam
9、eter Military part no. M24643/28 Type and size Number of conductors Diameter over core nom. (inch) min. (inch) max. (inch) -01UN LS1S50MU-16 16 0.655 0.760 0.825 -02UN LS1S50MU-20 20 0.760 0.835 0.905 -03UN LS1S50MU-40 40 1.015 1.095 1.185 -04UN LS1S50MU-70 70 1.380 1.465 1.555 TABLE II. Details (sh
10、ielded). Overall diameter (inch) Military part no. M24643/28 Type and size Number of conductors Diameter over core (inch) (nom.) min. max. -01UD LS1S50MUS-16 16 0.655 0.820 0.885 -02UD LS1S50MUS-20 20 0.760 0.895 0.965 -03UD LS1S50MUS-40 40 1.015 1.155 1.245 -04UD LS1S50MUS-70 70 1.380 1.525 1.615 R
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464328F2009CABLEELECTRICAL20DEGREECTO90DEGREECTYPELS1S50MUINCLUDINGVARIATIONLS1S50MUSLS1S50MU

链接地址:http://www.mydoc123.com/p-978653.html