1、F - 2 MIL-C-85253 3.3 m 9999906 03611309 5 II - ,- MIL-C-85253(AS) 13 June 1981 MILITARY SPECIFICATION CORD, DETONATING This specification is approved for use by the Naval Air Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defen
2、se. 1. SCOPE. 1.1 Scope. This specification establishes the requirements for manu- facture and acceptance of a detonating cord, critical item, referred to herein as the cord. I 2. APPLICABLE DOCUMENTS. 2.1 Issues of documents. The following documents, of the issue in effect on date of invitation for
3、 bids or request for proposal, form a part of this specification to the extent specified herein. SPECIFICATIONS - MILITARY MIL-S-23586 MIL-B-85251 Sealing Compound, Electrical, Silicone Rubber, Accelerator Required. Bomb, Binary Chemical, BLU;80/B. Beneficial comments (recommendations additions, del
4、etions) and any pertinent data which may be of use in improving this document should be.addressed to: Commanding Officer, Naval Air Engineering Center, Engineering Specifications and Standards Department (ESSD) Code 93, Lakehurst, NJ 08733, by using the self-addressed Standardization Document Improv
5、ement Proposal (DD Form 1426) appearing at the end of this document or by letter. . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-85253 (AS) STANDARDS FEDERAL * FED-STD-102 MI LI TARY MIL-STD-109 MIL-STD-129 MIL-STD-453 MIL-STD-810 MIL-STD-11
6、68 MIL-STD-45662 PUBLICATIONS Naval Sea Systems Command (Code Ident 10001) WS-5003 - T I Preservation, Packaging, and Packing Levels. Quality Assurance- Terms and Definitions. Marking for Shipment and Storage. Radiographic Inspection. Environmental Test Methods. Ammunition Lot Numbering. b Calibrati
7、on System Requirements. HNS Explosive. (Copies of specifications, standards, drawings, and publications re- quired by contractors in connection with specified procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 2.2 Other publications. The
8、following documents form a part of this specif icgtion to the extent specified herein. Unless otherwise indicated, the issue in effect on date of invitation for bids or request for proposal shall apply. DEPARTMENT OF TRANSPORTATION . Code of Federal Regulations. 49 CFR 171-178. Transportation. (Appl
9、ication for copies should be addressed to the Superintendent of Documents, Government Printing Off ice, Washington, D. C. 20402. ) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-, a 3. REQUIREPENTS . 3.1 Item description. The cord is. an aluminum
10、sheath containing 2.50 +0.25, -0.00 grains per foot (gr/ft) of Hexanitrostilebene (HNS), Type II, Grade A explosive recrystallized from an approved organic solvent system. 3.2 Characteristics. 3.2.1 Performance. 3.2.1 1 Detonation velocity. The cord shall have a detonation velocity of not less than
11、6,000 meters per second. 3.2.1.2 Low temperature. The cord shall withstand a temperature of -62 degrees Celsius (OC) for 336 hours without degradation of performance. 3.2.1.3 High temprature. The cord shall withstand a temperature of +74OC for 336 hours without degradation of performance. 3.2.1.4 Im
12、Dact resistance. The cord. when mounted on a steel I plate, shall not detonate, deflagrate, or burn when impacted with a 20.0 k0.5 pound solid-steel ball dropped from a height of 30.0 +0.5, -0.0 inches. . 8 3.2.1.5 Thermal shock. The cord shall withstand alternate sequential. exposure to temperature
13、s of -48OC for 90 minutes, +75OC for 30 minutes, and +254OC for 5 minutes without degradation of performance, and shall not constitute a safety hazard after exposure to thermal shock. 3.2.1,6 Plinimm bend radius. The cord shall withstand being bent on a radius of 0.5 inch without visual signs of cra
14、cking or splitting of the metal sheath or degradation of performance. 3.2.1.7 High temperature (safety). The cord shall withstand alternate sequential exposure to temperatures of +99 k3OC for 2 hours, +280 k3OC for 5 minutes, and +225 k3OC for 20 minutes without detonating or con- stituting a safety
15、 hazard after the thermal exposure. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-B5253 13 E 7979906 0364112 5 W MIL-C-85253(AS) 3.3 Design and construction. 3.3.1 Materials, processes, and parts. The design and construction of the cord sha
16、ll be as follows. 3.3.1.1 Material. The materials used in the manufacture of the cord shall be as follows: a. Sheath: Seamless fine aluminum of 99.9 percent minimum pur i ty . 3.3.1.2 Dimensions. The cord outside diameter shall be not less than 0.073 inch nor greater than 0.076 inch, 3.3.1.3 Splicin
17、g. The cord shall be a continuous length, and shall be free of splices. 3.3.1.4 Core load. The cord core load shall be 2.50 +0.25, -0.00 gr/ft. 3.3.1.5 Explosive uniformity. The explosive core and metal sheath shall be continuous and shall be free from gaps, voids, inclusions, or impurities. 3.3.2 S
18、tandards of manufacture. When specified in the contract or purchase order (see 6.2.2), the contractor shall include written certi- fication accompanied by objective quality evidence as defined in MIL- STD-109, that the materials, processes, and parts used in the cord meet the requirements of Section
19、 3. 3.3.3 Identification and marking. Each piece of cord shall be legibly identified to the run from which the cord was cut. On its leading end, attach a tag or tape with the suppliers lot number, sublot number, and sequence number marked in permanent ink. Individual lengths shorter than as specifie
20、d herein shall be marked by sequence number which iden- tify the position of that sequence length within a sublot (see Figure 1). Example : Lot Sublot Sequential lengths ABC79A018-001A -11 0 6 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-8
21、5253 13 7997706 03blll13 7 MIL-C-85253 (AS 1 t t I -i i: a I a 8 ii P 4 c -7 t 8- I 3-L: _. s II_c 1 5 _. . . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-C-85253 13 W 7999906 03b4LLY 7 W 3.4 First article. Unless otherwise specified in the c
22、ontract or purchase order, the contractor shall furnish a preproduction sample consisting of one completed drawtube for first article ,inspection and approval (see 4.1.2.1 and 6.2.1). The preproduction sample shall be manufactured using the sam methods, materials, processes, and pro- cedures propose
23、d for production. the preproduction sample shall be totally at the risk of the contractor. Any changes in material, design, and processes, used after the manu- facture of the preproduction sample, may be cause for resubmission of a preproduction sample. Any production prior to acceptance of 3.4.11 R
24、etest. At the discretion of the procuring activity, prepru- duction tests, or a,ny portion thereof, shall be repeateti under any of the following conditions: a. b. C. d. e. When the manufacturer has modified the product (such as a change of raw materials , processes, production procedures, or method
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILC852531981CORDDETONATING 爆炸 电线电缆 PDF