1、-1- JEDEC PUBLICATION Understanding Electrical Overstress - EOS JEP174 SEPTEMBER 2016 JEDEC SOLID STATE TECHNOLOGY ASSOCIATION NOTICE JEDEC standards and publications contain material that has been prepared, reviewed, and approved through the JEDEC Board of Directors level and subsequently reviewed
2、and approved by the JEDEC legal counsel. JEDEC standards and publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and ob
3、taining with minimum delay the proper product for use by those other than JEDEC members, whether the standard is to be used either domestically or internationally. JEDEC standards and publications are adopted without regard to whether or not their adoption may involve patents or articles, materials,
4、 or processes. By such action JEDEC does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the JEDEC standards or publications. The information included in JEDEC standards and publications represents a sound approach to product specification
5、 and application, principally from the solid state device manufacturer viewpoint. Within the JEDEC organization there are procedures whereby a JEDEC standard or publication may be further processed and ultimately become an ANSI standard. No claims to be in conformance with this standard may be made
6、unless all requirements stated in the standard are met. Inquiries, comments, and suggestions relative to the content of this JEDEC standard or publication should be addressed to JEDEC at the address below, or refer to www.jedec.org under Standards and Documents for alternative contact information. P
7、ublished by JEDEC Solid State Technology Association 2016 3103 North 10th Street Suite 240 South Arlington, VA 22201-2107 This document may be downloaded free of charge; however JEDEC retains the copyright on this material. By downloading this file the individual agrees not to charge for or resell t
8、he resulting material. PRICE: Contact JEDEC Printed in the U.S.A. All rights reserved -3- PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by JEDEC and may not be reproduced without permission. For information, contact: JEDEC Solid State Technology Association 3103 North 10th Street Suite
9、240 South Arlington, VA 22201-2107 or refer to www.jedec.org under Standards-Documents/Copyright Information. JEDEC Publication No. 174 -i- UNDERSTANDING ELECTRICAL OVERSTRESS - EOS Contents Introduction . iii I.1 Purpose iii I.2 Traditional Perceptions of EOS . iv I.3 Industry Council Worldwide Sur
10、vey . iv I.4 New Definition of EOS Incorporating AMR and EIPD . v I.5 EOS Root Causes . vii I.6 EOS Root Cause Diagnostics viii I.7 EOS Case Studies and IC Designs ix I.8 EOS Mitigation and Communication . x I.9 Summary x I.10 Outlook. x 1 Scope 1 2 References . 1 3 Terms and Definitions 7 4 History
11、 of EOS . 9 4.1 Outline of History of Relevant Professional Societies . 11 4.2 EOS A Brief History . 11 4.3 Transition to Present 14 5 EOS Damage in the Factory and Field . 15 5.1 Motivation for Field Returns Analysis of Failures Exhibiting EOS Damage 15 5.2 Transients . 16 5.3 EOS Survey for Gather
12、ing Data on EOS Damage . 17 5.4 Impact of EOS Damage . 32 5.5 Failure Reports of Products Exhibiting EOS Damage . 33 6 The Definition of EOS Finding Common Understanding 34 6.1 Existing Documentation Practices of AMR Values . 35 6.2 Unified Understanding of AMR and EOS 37 6.3 Additional Comments on
13、Usage of the Term “EOS” . 38 6.4 Conclusion . 38 7 EOS Root Causes 39 7.1 Root Cause Categories . 39 7.2 EOS Damage during Unpowered Handling . 40 7.3 EOS during Powered Handling 43 7.4 EOS Damage during AC Operation and Switching . 47 7.5 Analysis of Electrically Induced Physical Damage and Conclus
14、ions on EOS Events . 48 8 Case Studies on EOS 50 8.1 Case 1: Incorrect ESD Qualification Leading to EOS . 51 8.2 Case 2: EOS Due to Misapplication . 54 8.3 Case 3: EOS due to Hot Plugging 57 8.4 Case 4: EOS due to Intermittent Battery Ground Connection 61 8.5 Case 5: EOS due to Ground Offset 63 8.6
15、Case 6: EOS Case Study “Automotive Knock Sensor“ 65 8.7 Case 7: EMI Transient Surge 70 8.8 Case 8: EMI Board Design 73 8.9 Case 9: Supply Capacitor Switching 76 8.10 Case 10: CBE in DSP IC 78 8.11 Case 11: Reliability Testing . 83 8.12 Lessons Learned . 88 8.13 Conclusions 88 JEDEC Publication No. 1
16、74 -ii- 9 EOS Analysis and Diagnosis - “Techniques and Methods for Dealing with Electrically Induced Physical Damage” 89 9.1 Optimal Customer and Supplier Failure Symptom Information Exchange and Device Handling . 89 9.2 EOS FA Challenges . 90 9.3 High Level Preparation Guidelines for Diagnosing the
17、 Cause of EOS 92 9.4 Failure Analysis Techniques and Procedures . 92 9.5 Analysis of Damage Mechanisms for EOS 102 9.6 Overstress Power vs. Time . 107 9.7 Final Diagnosis of the Cause and Conclusion 108 10 Minimization and Mitigation of EOS . 112 10.1 Lessons Learned to Minimize EOS Damage 112 10.2
18、Automotive Studies 117 10.3 Integrated Circuit Trends and EOS Effects 122 10.4 Communication with Customers 134 10.5 Recommendations for EOS Minimization and Mitigation . 136 10.6 Conclusions 137 11 Summary and Conclusions 138 Annex A: EOS Survey Form . 140 Annex B: The Dwyer Curve and EOS Damage at
19、 a Temperature Threshold 146 B.0 Background and 1-Dimensional Heat Flow . 146 B.1 Heat Flow as an RC Transmission Line . 147 B.2 Thermal Impedance and the Jacobi Theta4 Function . 148 B.3 The Analytic Dwyer Curve Approximation . 150 B.4 Utility of the Dwyer Curve and Thermal Impedance Approximations
20、 155 Annex C: Frequently Asked Questions . 156 JEDEC Publication No. 174 -iii- Foreword Damage signatures from Electrical Overstress (EOS) are the leading reported cause of returns in integrated circuits and systems that have failed during operation. Solutions to this problem are hindered by a preva
21、iling misconception in the electronics industry that insufficient robustness to electrostatic discharge (ESD) is a primary cause of EOS. This document, White Paper 4, (WP) has been carefully compiled by the Industry Council on ESD Target Levels to foster a unified global understanding of what consti
22、tutes EOS and how EOS damage signatures can result from a wide variety of root causes. The paper begins by outlining a brief history of EOS. It then presents the results of an industry-wide EOS survey. This survey gathered information on the types of EOS problems experienced by over 80 different com
23、panies, the relative importance of EOS to their overall business, and the methods assigned by these companies to address EOS issues. The survey provides a combined picture from which a more comprehensive definition of EOS can be made. The numerous categories and sub-categories of EOS root causes are
24、 explored in an attempt to understand how to create better specifications which will reduce their occurrence. In addition to the survey results, this paper studies many field returns with EOS damage signatures to establish the underlying root causes of damage and offers the respective identified sol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JEDECJEP1742016UNDERSTANDINGELECTRICALOVERSTRESSEOSPDF

链接地址:http://www.mydoc123.com/p-806999.html