JEDEC JEP172A-2015 Discontinuing Use of the Machine Model for Device ESD Qualification.pdf
《JEDEC JEP172A-2015 Discontinuing Use of the Machine Model for Device ESD Qualification.pdf》由会员分享,可在线阅读,更多相关《JEDEC JEP172A-2015 Discontinuing Use of the Machine Model for Device ESD Qualification.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、JEDEC PUBLICATION Discontinuing Use of the Machine Model for Device ESD Qualification JEP172A (Revision of JEP172, July 2014 JULY 2015 JEDEC SOLID STATE TECHNOLOGY ASSOCIATION NOTICE JEDEC standards and publications contain material that has been prepared, reviewed, and approved through the JEDEC Bo
2、ard of Directors level and subsequently reviewed and approved by the JEDEC legal counsel. JEDEC standards and publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products
3、, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for use by those other than JEDEC members, whether the standard is to be used either domestically or internationally. JEDEC standards and publications are adopted without regard to whether or not their ado
4、ption may involve patents or articles, materials, or processes. By such action JEDEC does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the JEDEC standards or publications. The information included in JEDEC standards and publications rep
5、resents a sound approach to product specification and application, principally from the solid state device manufacturer viewpoint. Within the JEDEC organization there are procedures whereby a JEDEC standard or publication may be further processed and ultimately become an ANSI standard. No claims to
6、be in conformance with this standard may be made unless all requirements stated in the standard are met. Inquiries, comments, and suggestions relative to the content of this JEDEC standard or publication should be addressed to JEDEC at the address below, or refer to www.jedec.org under Standards and
7、 Documents for alternative contact information. Published by JEDEC Solid State Technology Association 2015 3103 North 10th Street Suite 240 South Arlington, VA 22201-2107 This document may be downloaded free of charge; however JEDEC retains the copyright on this material. By downloading this file th
8、e individual agrees not to charge for or resell the resulting material. PRICE: Contact JEDEC Printed in the U.S.A. All rights reserved PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by JEDEC and may not be reproduced without permission. For information, contact: JEDEC Solid State Technol
9、ogy Association 3103 North 10th Street Suite 240 South Arlington, VA 22201-2107 or refer to www.jedec.org under Standards-Documents/Copyright Information. JEDEC Publication No. 172A -i- DISCONTINUING USE OF THE MACHINE MODEL FOR DEVICE ESD QUALIFICATION Contents 1 Scope 1 2 References 1 3 Terms, Def
10、initions, and Letter Symbols 2 4 Background 3 5 MM vs. HBM and CDM 4 6 Metal Discharge versus CDM Discharge . 6 7 Field Data Analysis 9 8 Standards Bodies and Positions on MM. 9 9 Conclusions 10 10 Epilogue . 10 11 Common Goals . 10 Annex A Differences between JEP172A and JEP172 10 JEDEC Publication
11、 No. 172A -iii- Foreword The machine model test, as a requirement for component ESD qualification, is being rapidly discontinued across the industry. This publication is intended to document why MM evaluation is not necessary for qualification. The following major conclusions can be made about MM in
12、 general: MM is redundant to HBM at the device level since it produces the same failure mechanisms, and the two models generally track each other in robustness and in failure modes produced. The MM test has more variability and, consequently, less repeatability than HBM due to the MMs greater sensit
13、ivity to parasitic effects in the tester circuitry. There are no significant engineering studies (with verified data) which could be used to establish a required passing level for MM. The test method was incorrectly given the name “machine model”, though no firm, unique connection between the model
14、and actual machine-induced device failures was ever established. In fact the model was developed as a “low-voltage HBM”. CDM does a better job of screening for fast metal-to-metal contact events than MM. The vast majority ( 99%) of electrical failures in manufacturing correlate to CDM or to EOS and
15、not to MM. MM testing has not shown any additional failures not explained by CDM, HBM or EOS. MM testing consumes resources and creates time-to-market delays while providing no additional failure modes or protection strategies which have not been covered by HBM and CDM. It is important to understand
16、 the scope of this memorandum. It summarizes what has been learned about the test method only. The information summarized here in no way diminishes the importance of proper grounding of any metal which may come in contact with ESD-sensitive devices or the importance of avoiding hard metal-to-metal d
17、ischarges. JEDEC Publication No. 172A Page 1 DISCONTINUING USE OF THE MACHINE MODEL FOR DEVICE ESD QUALIFICATION (From Board Ballot JCB-14-27, formulated under the cognizance of the JC-14.3 Subcommittee on Silicon Devices Reliability Qualifications and Monitoring.) 1 Scope Over the last several deca
18、des the so called “machine model“ (aka MM) and its application to the required ESD component qualification has been grossly misunderstood. The scope of this JEDEC document is to present evidence to discontinue use of this particular model stress test without incurring any reduction in the IC compone
19、nts ESD reliability for manufacturing. In this regard, the documents purpose is to provide the necessary technical arguments for strongly recommending no further use of this model for IC qualification. The published document should be used as a reference to propagate this message throughout the indu
20、stry. 2 References 1 JEDEC JESD47 “Stress-Test-Driven Qualification of Integrated Circuits”, www.jedec.org 2 JEDEC JESD22-A115 “Electrostatic Discharge (ESD) Sensitivity Testing Machine Model (MM)”, www.jedec.org 3 ANSI/ESD STM5.2-2012 “Machine Model (MM) Component Level “ www.esda.org 4 M. Tanaka,
21、JEITA/JEDEC Meetings, Tokyo, September 2011. 5 M. Tanaka, K. Okada, and M. Sakimoto, “Clarification of Ultra-high-speed Electrostatic Discharge and Unification of Discharge Model,” EOS/ESD Symposium, pp, 170-181, 1994. 6 Industry Council on ESD Target Levels, “White Paper 1: A Case for Lowering Comp
22、onent Level HBM/MM ESD Specifications and Requirements,” August 2007, at www.esda.org or JEDEC publication JEP155, “Recommended ESD Target Levels for HBM/MM Qualification”, www.jedec.org 7 ANSI/ESD S20.20 - For the Development of an Electrostatic Discharge Control Program 8 ESDA standards document d
23、efinitions and hierarchy are summarized at www.esda.org/Documents.html JEDEC Publication No. 172A Page 2 3 Terms, Definitions, and Letter Symbols AEC Automotive Electronics Council ANSI American National Standards Institute CDM charged-device model EOS electrical overstress EPA ESD protected area ES
24、D electrostatic discharge ESDA Electrostatic Discharge Association; ESD Association FAR failure analysis report HBM human body model IC integrated circuit JEDEC JEDEC Solid State Technology Association JEITA Japan Electronics and Information Technology Industries Association MM machine model OEM ori
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JEDECJEP172A2015DISCONTINUINGUSEOFTHEMACHINEMODELFORDEVICEESDQUALIFICATIONPDF

链接地址:http://www.mydoc123.com/p-806998.html