FORD WSK-M1L127-A2-2003 CABLE LOW TENSION PFA INSULATED 260 THIN WALL SHIELDED AND TWISTED NICKEL PLATED TWO CORE TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度260℃的薄壁可溶性聚四氟乙烯(PFA)绝.pdf
《FORD WSK-M1L127-A2-2003 CABLE LOW TENSION PFA INSULATED 260 THIN WALL SHIELDED AND TWISTED NICKEL PLATED TWO CORE TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度260℃的薄壁可溶性聚四氟乙烯(PFA)绝.pdf》由会员分享,可在线阅读,更多相关《FORD WSK-M1L127-A2-2003 CABLE LOW TENSION PFA INSULATED 260 THIN WALL SHIELDED AND TWISTED NICKEL PLATED TWO CORE TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度260℃的薄壁可溶性聚四氟乙烯(PFA)绝.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 08 18 Revised Para 3.0 inserted; Para 3.1, 3.2, 3.21, 4 deleted 1992 10 10 EE00E10176310000 Pages 1,.3, 9 & 10 Revised MD/FE-12 P. Rade 1992 07 10 EGE0E10221454000 Released MD/FE-12 P. Rade Printed copies are uncontrolled Copyright 2003,
2、Ford Global Technologies, Inc. Page 1 of 7 CABLE, LOW TENSION, PFA INSULATED, 260 C, THIN WSK-M1L127-A2 WALL, SHIELDED AND TWISTED, NICKEL PLATED, TWO CORE 1. SCOPE The material defined by this specification is a low tension stranded cable, perlfluoro alkoxyl alkane (PFA) insulated conductor. The ca
3、ble is similar to ISO 6722 with a thin wall insulation thickness. It is a spirally wound shielded and twisted wire with a 90% shield cover and a helix angle of 10%. 2. APPLICATION This specification was released originally for materials used in automotive electrical harnesses. Note: The assemblers o
4、f electrical wire harnesses shall use the bulk wire suppliers as shown in the Ford Motor Company Approved Source List. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials
5、(WSS-M99P1111-A). 3.3 CABLE 3.3.1 Specimen Length 1.2 m 3.3.2 The maximum outside diameter shall be determined by taking measurements at three points along the conductor length separated by at least 100 mm and recording the greatest overall diameter at each point. No single value shall exceed the ma
6、ximum overall diameter as specified in Table 2. 3.4 CONDUCTOR 3.4.1 The conductor of all cable classes shall consist of bunched or stranded soft annealed copper wire. 3.4.2 Specimen Length 1.2 m 3.4.3 Three sections 10 mm long and separated by at least 400 mm shall be cut from the specimen. Carefull
7、y remove the conductor without deformation of the insulation. 3.4.4 The conductor diameter shall be determined by measuring the inside diameter of the insulation taken at three points separated by at least 100 mm and recording the maximum inside diameter at each point. The measurements shall be made
8、 with an optical device accurate to at least 0.01 mm. No value shall exceed the maximum diameter of the conductor specified in Table 2. ENGINEERING MATERIAL SPECIFICATIONWSK-M1L127-A2Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 7 3.4.5 The conductor area m
9、ay be determined by measuring individual strand diameters and calculating the sums of the individual strand areas. As an alternate method, conductor area may also be determined in accordance with FLTM BB 105-01 or by measuring the resistance in accordance with table 1. 3.4.6 The strands shall be bun
10、ched and the maximum lay length shall be a maximum of 50 times the conductor diameter. Minimum number of wires shall comply with Tables 1 and 2. Maximum variation between individual strand diameters must not exceed 10 percent per the following: Variation = max strand dia - min strand dia _ min stran
11、d dia Missing strands are not allowed. 3.4.7 Elongation (ASTM B 3) for d 15% for d 0.287 mm e 20% where: d = individual strand diameter e = elongation of individual strand 3.4.8 Resistivity, max 1.7544 /cm (ASTM B 193, at 20 C) 3.5 INSULATION AND SHEATHING 3.5.1 The insulating material shall be a pe
12、rlfluoro alkoxyl alkane (PFA) material, homogeneous in character. The surface shall be smooth and even without cracks, knots, blisters, or other faults. 3.5.2 The color of the cables are per the Munsell Color Coding System and shall conform to Table 3. Comparison must be made by a person with normal
13、 or corrected vision, under cool white fluorescent lighting. The surface being inspected and the tolerance set must be in the same plane. Cable samples must be placed flat, overlapping the color standard. Color tolerance Reference Sets are available from SAE, 400 Commonwealth Drive, Warrendale, PA 1
14、5096. As an alternative, the color of the cables can be per the DIN 47002 or IEC 304 and shall conform to Table 4. 3.5.3 The minimum insulation thickness shall be determined by taking measurements at three points separated by at least 100 mm and recording the minimum insulation thickness at each poi
15、nt. The thickness shall be measured with an optical device accurate to at least 0.01 mm. No single value shall be lower than the minimum insulation thickness specified in Table 2. ENGINEERING MATERIAL SPECIFICATIONWSK-M1L127-A2Printed copies are uncontrolled Copyright 2003, Ford Global Technologies,
16、 Inc. Page 3 of 7 3.6 CABLE CONSTRUCTION 1= CONDUCTOR NICKEL PLATED 2= INSULATION PFA 3= SHIELDING SPIRALLY WOUND SHIELD, NICKEL PLATED. 90% SHIELD COVER, HELIX ANGLE 10 DEGREE 4= SHEATHING PFA (BLACK) LAY LENGTH = 45 mm 3.7 FAULT TESTING OF THE COMPLETE DELIVERY (in process testing) 3.7.1 When pull
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSKM1L127A22003CABLELOWTENSIONPFAINSULATED260THINWALLSHIELDEDANDTWISTEDNICKELPLATEDTWOCORETOBEUSEDWITHFORDWSSM99P1111A

链接地址:http://www.mydoc123.com/p-750340.html