FORD WSK-M1L127-A-2003 CABLE LOW TENSION PTFE INSULATED 260 THIN WALL NICKEL PLATED TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度260℃的薄壁聚四氟乙烯(PTFE)绝缘的低压镀镍电缆 与标准FORD WSS-M99P1111-A.pdf
《FORD WSK-M1L127-A-2003 CABLE LOW TENSION PTFE INSULATED 260 THIN WALL NICKEL PLATED TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度260℃的薄壁聚四氟乙烯(PTFE)绝缘的低压镀镍电缆 与标准FORD WSS-M99P1111-A.pdf》由会员分享,可在线阅读,更多相关《FORD WSK-M1L127-A-2003 CABLE LOW TENSION PTFE INSULATED 260 THIN WALL NICKEL PLATED TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度260℃的薄壁聚四氟乙烯(PTFE)绝缘的低压镀镍电缆 与标准FORD WSS-M99P1111-A.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 08 13 Revised Para 3.0 inserted; Para 3.1, 3.5, 3.19, 4 deleted 1992 10 10 EE00E10176310000 Pages 1,3,4,8,9 Rev MD/FE-12 P. Rade 1990 10 23 EE00I0051754002 Released MD/PL-10 U. Schwarz Printed copies are uncontrolled Copyright 2003, Ford
2、Global Technologies, Inc. Page 1 of 7 CABLE, LOW TENSION, PTFE INSULATED, 260 C WSK-M1L127-A THIN WALL, NICKEL PLATED 1. SCOPE The material defined by this specification is a low tension stranded cable, polytetrafluoroethylene (PTFE) or perlfluoro alkoxyl alkane (PFA) insulated conductor. The cable
3、is similar to ISO 6722 with a thin wall insulation thickness. 2. APPLICATION This specification was released originally for materials used in automotive electrical harnesses. Note: The assemblers of electrical wire harnesses shall use the bulk wire suppliers as shown in the Ford Motor Company Approv
4、ed Source List. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A) 3.2 CABLE 3.2.1 Specimen Length 1.2 m 3.2.2 The maximum outside diameter shall be dete
5、rmined by taking measurements at three points along the conductor length separated by at least 100 mm and recording the greatest overall diameter at each point. No single value shall exceed the maximum overall diameter as specified in Table 2. 3.3 CONDUCTOR 3.3.1 The conductor of all cable classes s
6、hall consist of bunched or stranded soft annealed copper wires. 3.3.2 Specimen Length 1.2 m 3.3.3 Three sections 10 mm long and separated by at least 400 mm shall be cut from the specimen. Carefully remove the conductor without deformation of the insulation. 3.3.4 The conductor diameter shall be det
7、ermined by measuring the inside diameter of the insulation taken at three points separated by at least 100 mm and recording the maximum inside diameter at each point. The measurements shall be made with an optical device accurate to at least 0.01 mm. No value shall exceed the maximum diameter of the
8、 conductor specified in Table 2. ENGINEERING MATERIAL SPECIFICATIONWSK-M1L127-APrinted copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 7 3.3.5 The conductor area may be determined by measuring individual strand diameters and calculating the sums of the individual str
9、ands areas. As an alternate method, conductor area may also be determined in accordance with FLTM BB 105-01 or by measuring the resistance in accordance with table 1. 3.3.6 The strands shall be bunched and the maximum lay length shall be a maximum of 50 times the conductor diameter. Minimum number o
10、f wires shall comply with Tables 1 and 2. Maximum variation between individual strand diameters must not exceed 10% per the following: Variation = max strand dia-min strand dia min strand dia Missing strands are not allowed. 3.3.7 Elongation (ASTM B 3) for d 15% for d 0.287 mm e 20% where: d = indiv
11、idual strand diameter e = elongation of individual strand. 3.3.8 Resistivity, max 1.7544 /cm (ASTM B 193, at 20 C) 3.4 INSULATION 3.4.1 The insulating material shall be a polytetrafluoroethylene (PTFE) or perlfluoro alkoxyl alkane (PFA) material, homogeneous in character. The surface shall be smooth
12、 and even without cracks, knots, blisters, or other faults. 3.4.2 The color of the cables are per the Munsell Color Coding System and shall conform to Table 3. The following method shall be used to evaluate the color of the cables. Comparison must be made by a person with normal or corrected vision,
13、 under cool white fluorescent lighting. The surface being inspected and the tolerance set must be in the same plane. Cable samples must be placed flat, overlapping the color standard. Color tolerance Reference Sets are available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096. As an alternati
14、ve, the color of the cables can be per the DIN 47002 or IEC 304 and shall conform to Table 4. 3.4.3 The minimum insulation thickness shall be determined by taking measurements at three points separated by at least 100 mm and recording the minimum insulation thickness at each point. The thickness sha
15、ll be measured with an optical device accurate to at least 0.01 mm. No single value shall be lower than the minimum insulation thickness specified in Table 2. ENGINEERING MATERIAL SPECIFICATIONWSK-M1L127-APrinted copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 3 of 7 3.6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSKM1L127A2003CABLELOWTENSIONPTFEINSULATED260THINWALLNICKELPLATEDTOBEUSEDWITHFORDWSSM99P1111A 最高

链接地址:http://www.mydoc123.com/p-750339.html