FORD FLTM BI 109-3-2001 COLOR DIFFERENCE EVALUATION OF TEXTILE MATERIALS.pdf
《FORD FLTM BI 109-3-2001 COLOR DIFFERENCE EVALUATION OF TEXTILE MATERIALS.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BI 109-3-2001 COLOR DIFFERENCE EVALUATION OF TEXTILE MATERIALS.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BI 109-03 Date Action Revisions 2001 03 14 Revised Editorial no technical change A. Cockman 1996 10 24 Printed copies are uncontrolled Page 1 of 8 Copyright 2001, Ford Global Technologies, Inc. COLOR DIFFERENCE EVALUATION OF TEXTILE MATERIALS Application This procedure d
2、escribes a method for determining the quantitative color difference between any two textile materials which meet the measurability requirements. Apparatus Required Spectrophotometer Macbeth MS2000, MS2020 or Micromatch spectrophotometer system. Source: Instrumental Color Systems Ltd. Kennetside, Ken
3、netside Park Industrial Estate Newbury, Berkshire RTG14 5TE Equivalent spectrophotometers may also be used provided they have been given prior approval by Ford Motor Company. In cases of dispute, the above system as used by Ford Materials Engineering will be used as referee. Optical Geometry Sample
4、shall be diffusely illuminated by means of a diffusing sphere. The angle of vi ewing shall not exceed 10. The converse geometry of illumination 0.008856 but L* = 903.3(Y/Yn) if Y/Yn 0.008856 but f(X/Xn) = 7.787(X/Xn) + 16/116 if X/Xn 0.00856 but f(Z/Zn) = 7.87(Z/Zn)1/3 + 16/116 if Z/Zn or = 1.0 desc
5、ribes an ellipsoid volume with axes in the direction of lightness, chroma and hue centered about a standard. Ellipsoid semi-axes lengths of 1SL, cSC and SH calculated for a given standard describe a unit volume of acceptance within which all samples are less than 1.0 DEcmc unit from the standard. Th
6、is volume and the size and the ratio of its semi-axes becomes the basis for the establishment of an appropriately sized volume of acceptability for a given commercial situation by the application of commercial factor (cf) to all dimensions. The volume of acceptance is defined by DEcmc = cf Note: The
7、 size and the orientation of the ellipsoid varies considerably depending on location of standard in color space. Interpretation of Results The color difference between two specimens can be partitioned into components of lightness, chroma and hue. Lightness Component The lightness component is calcul
8、ated for use in the equation for DE and L*/1SL , and is the difference in lightness between the test specimen and the reference specimen; it is designated DL. The nature of any lightness difference can be derived from the following equation: L = LT* - LR* If * is positive the test specimen is lighte
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBI10932001COLORDIFFERENCEEVALUATIONOFTEXTILEMATERIALSPDF

链接地址:http://www.mydoc123.com/p-746983.html