1、FORD MANUFACTURING STANDARDS EWl JUNE 1993 POWER DISTRIBUTION FROM BUS DUCT SYSTEMS EWl Page 1 1. 1.1 1.2 1.3 2. 2.1 2.2 GENERAL: SCOPE: This standard describes the installation of bus drop cable, supports required, and devices and methods of terminating the cable. (See illustration on page 5). It a
2、lso describes conduit installations where the use of bus drop cable is not practicable. Whenever a specific standard is mentioned in this Standard, it is understood it will be the latest revision thereof unless otherwise specified. SAFETY: Refer to Ford Industrial Relations Safety Technical Bulletin
3、 No. 133 - “Safety Guidelines for the Installation of Electrical Distri- bution Busway Plug-in Units on Energized Busways“ for procedures to follow when installing or removing Busplugs. REFERENCE STANDARDS: ANSI/NFPA 70, “National Electric Code“. ASTM B-8, “Specification for Concentric-Lay Stranded
4、Copper Conductors, Hard, Medium-Hard or Soft“. ASTM B-174, “Specification for Bunch-Stranded Copper Conductors for Electrical Conductors“. ICEA S-61-402/NEMA WC 5, “Thermoplastic-insulated Wire and Cable for the Transmission and Distribution of Electrical Energy“. Ford Manufacturing Standards EEl, E
5、E2, EE4, and EXl Canadian Standards Association (CSA) C22.10, “Canadian Electric Code Part I (16th Ed.) plus Quebec Amendment“. BUS DROP CABLE: SIZE: The size of the cable shall suit the power requirements of the industrial equipment served. In no case shall it be smaller than size AWG (American Wir
6、e Gage) 12, or larger than size AWG 2. The cable shall include three power conductors and a grounding wire or wires. Section 6.0 describes installations requiring sizes larger than AWG 2. CONDUCTORS: Each conductor shall have at least seven strands of soft drawn. annealed Conner ner ASTM B-8 Class C
7、 or B-174 Class K- m =ill!J=iLbD 0051bi3 373 - FORD MANUFACTURING STANDARDS EWl JUNE 1993 POWER DISTEIBUTION FEOM BUS DUCT SYSTEMS Page 2 2.3 INSULATION: The cable shall be rated 600 VAC, minus 20 to +75 deg.C, be Underwriters Laboratories, Inc. (UL) Listed, and conform to ICEA and National Electric
8、al Code requirements. Individual thermoplastic insulated conductors shall be colored black, white, and red. The grounding wire or wires need not be insulated or if insulated they shall be green. The thermoplastic cable jacket shall be oil, water, ozone, corrosives and abrasion resistant. 3. TERMINAT
9、IONS: 3.1 All cable grips used under this standard shall be UL Listed and/ or CSA certified as required at the location where the equipment is to be installed. Holes in enclosures shall be ma& only with manually or hydraulically operated punches and dies, except for knockouts furnished in some types
10、 of bus plugs. Ground wires in the bus drop cable shall be twisted together and properly bonded to the enclosure at each termination with ring type crimp terminals or to lugs provided for this purpose. Plastic insulated bushings shall be installed on the threaded end of the grip connectors inside al
11、l enclosures, and are typically furnished with the connector. 3.2 TERMINATIONS AT THE BUS PLUG: Where the cable terminates at the bus plug, it shall pass through a wide-range strain relief grip having a neoprene gasket or seal around the cable to exclude dust. The connector portion of the grip shall
12、 have an attached single/double weave, stainless steel mesh extending at least five inches along the cable to prevent its pull out at the terminals inside the bus plug, control its bend radius and relive strain, in accordance with National Electrical Code sections 364-8 and 400-10. The grip shall be
13、 sized to avoid any stripping of the cable jacket where it passes through the connector body. 3.3 TERMINATIONS AT THE CONTROL ENCLOSURE (over 6 feet): Where the top of the control enclosure is six feet or more above the floor, the bus drop cable shall enter the enclosure through a deluxe cord grip,
14、which has the same mesh as the strain relief grip, but adds a neoprene grommet and compression nut to exclude both dust and liquids. A wide-range strain relief grip may be used, if permitted in writing by the specifying activity. FORD MANUFACTURING STANDARDS Ewl JUNE 1993 POWER DISTRIBUTION FROM BUS
15、 DUCT SYSTEMS EWl Page 3 3.4 TERMINATIONS AT THE CONTROL ENCLOSURE (under 6 feet): Where the top of the control enclosure is less than six feet from the floor, the bus drop cable shall be protected by a conduit riser to a height of eight feet above the floor. The strain relief grip and connector sha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDEW11993POWERDISTRIBUTIONFROMBUSDUCTSYSTEMS 母线 管道 系统 配电 PDF

链接地址:http://www.mydoc123.com/p-746696.html