FORD ESF-M1L92-A2-2010 CABLE BATTERY CROSS LINKED POLYETHYLENE JACKET TO BE USED WITH FORD WSS-M99P1111-A 《电缆 电池 交叉相连的聚乙烯护套 与福特WSS-M99P1111-A 一起使用 在福特ESF-M1L92-A中显示》.pdf
《FORD ESF-M1L92-A2-2010 CABLE BATTERY CROSS LINKED POLYETHYLENE JACKET TO BE USED WITH FORD WSS-M99P1111-A 《电缆 电池 交叉相连的聚乙烯护套 与福特WSS-M99P1111-A 一起使用 在福特ESF-M1L92-A中显示》.pdf》由会员分享,可在线阅读,更多相关《FORD ESF-M1L92-A2-2010 CABLE BATTERY CROSS LINKED POLYETHYLENE JACKET TO BE USED WITH FORD WSS-M99P1111-A 《电缆 电池 交叉相连的聚乙烯护套 与福特WSS-M99P1111-A 一起使用 在福特ESF-M1L92-A中显示》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions 2010 12 08 Revised Inserted Minimum Diameter of Finished Cable to Table II M. Gramlich, NA 2003 04 28 Revised Para 3.0 inserted; Para 3.6, 3.7, 3.8, 3.9, 3.10, 4 deleted 1973 12 14 AC4-39 Released (Was XF-M1LX13) Printed copies are uncontroll
2、ed Copyright 2010, Ford Global Technologies, Inc. Page 1 of 5 CABLE, BATTERY, CROSS LINKED POLYETHYLENE JACKET ESF-M1L92-A CABLE, BATTERY, CROSS LINKED POLYETHYLENE JACKET ESF-M1L92-A2 1. SCOPE The materials defined by this specification are stranded, flame retardant cross-linked polyethylene covere
3、d low tension cables, which shall have a maximum continuous service temperature of 125 C. 2. APPLICATION This specification was released originally for material used for higher temperature battery cables. 3. REQUIREMENTS Shall conform to SAE J1127 except as follows: 3.0 STANDARD REQUIREMENTS FOR PRO
4、DUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 WIRE SIZE The wire size shall be specified on engineering drawings and/or releases according to the SAE wire size numbers appearing in Table I. Ex
5、ample: #4 gage ESF-M1L92-A 3.2 CABLE QUALITY The materials shall meet all of the requirements listed herein and shall be equal to the original approved sample. 3.3 WIRE QUALITY The strands of the conductors prior to stranding shall consist of ESF-M2L1-A, soft or annealed bare copper wire. 3.4 CABLE
6、CONSTRUCTION See Tables I and II ENGINEERING MATERIAL SPECIFICATION ESF-M1L92-A/A2 Printed copies are uncontrolled Copyright 2010, Ford Global Technologies, Inc. Page 2 of 5 3.5 INSULATION QUALITY Shall be a good grade of flame retardant cross-linked polyethylene which will pass the following test r
7、equirements: Shall adhere closely to, but strip readily from, the conductors leaving them reasonably clean and in suitable condition for soldering. Insulation thickness shall be in accordance with Table II for the various wire sizes and shall be determined by measuring the diameter over the insulati
8、on, then removing the insulation and measuring the diameter of the conductor. Half of the difference of the two measurements shall be considered as the average wall thickness. For any cross section of a test specimen, the minimum wall thickness shall not be less than 50% of the maximum wall thicknes
9、s. 3.5.1 Mechanical Properties A test specimen of the flame retardant cross-linked polyethylene insulation prepared as in the SAE J200 section on sampling, shall be used. The dumbbell cut sample shall have marks placed upon it 60 mm apart. The sample shall then be stretched at the rate of 300 mm/min
10、ute. The tensile strength shall be calculated upon the original cross section of the test specimen before stretching. Testing shall be conducted at 23 +/- 2 C. Care should be exercised in cutting samples to obtain uniform cross section. The physical properties shall be as follows: Tensile Strength,
11、min 10.4 MPa Elongation, min 200% 3.5.2 High Temperature Resistance One test specimen 25 mm long of the insulation shall be removed from each end of a 610 mm sample of the finished cable. The sample shall be suspended around a cylindrical mandrel having a diameter specified in Table III. Each end of
12、 the conductor shall have suspended from it, the weight shown in Table III. This condition shall be maintained for 120 h in a mechanical convection oven maintained at a temperature of 177 +/- 3 C. When cool, the weight shall be removed from the specimen and it shall be taken off the mandrel, bent in
13、 the reverse direction around a mandrel of the diameter specified for the bend test in Table III at a rate not to exceed one complete turn/minute and then be subjected to the dielectric test, para 3.5.3. 3.5.3 Dielectric Test A specimen of the cable 610 mm long shall be formed into a loop. One test
14、specimen 25 mm long of the insulation shall be removed from each end of the wire and the ends twisted together. The loop thus formed shall be immersed in water containing 5 % salt by weight at 23 +/- 2 C, so that not more than 152 mm each end of the specimen protrudes above the solution. After being
15、 immersed for 5 h and while still immersed, the specimen shall withstand the application of 1000 volts (rms) at 60 Hz between the conductor and the water for 1 minute without rupture of the insulation. ENGINEERING MATERIAL SPECIFICATION ESF-M1L92-A/A2 Printed copies are uncontrolled Copyright 2010,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESFM1L92A22010CABLEBATTERYCROSSLINKEDPOLYETHYLENEJACKETTOBEUSEDWITHFORDWSSM99P1111A 电缆 电池 交叉 相连 聚乙烯

链接地址:http://www.mydoc123.com/p-746127.html