EN 62493-2015 en Assessment of lighting equipment related to human exposure to electromagnetic Field.pdf
《EN 62493-2015 en Assessment of lighting equipment related to human exposure to electromagnetic Field.pdf》由会员分享,可在线阅读,更多相关《EN 62493-2015 en Assessment of lighting equipment related to human exposure to electromagnetic Field.pdf(70页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationAssessment of lighting equipment related to human exposure to electromagnetic fieldBS EN 62493:2015National forewordThis British Standard is the UK implementation of EN 62493:2015. It is identical to IEC 62493:2015. It supersedes BS EN 62493:2010, which will bewithdrawn on 7
2、 March 2018.The UK participation in its preparation was entrusted to TechnicalCommittee CPL/34, Lamps and Related Equipment.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa c
3、ontract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 82417 3ICS 29.020; 29.140.01Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published und
4、er the authority of theStandards Policy and Strategy Committee on 31 May 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 62493:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 62493 May 2015 ICS 29.020; 29.140 Supersedes EN 62493:2010 English Versio
5、n Assessment of lighting equipment related to human exposure to electromagnetic Field (IEC 62493:2015) valuation dun quipement dclairage relativement lexposition humaine aux champs lectromagntiques (IEC 62493:2015) Beurteilung von Beleuchtungseinrichtungen bezglich der Exposition von Personen gegenb
6、er elektromagnetischen Feldern (IEC 62493:2015) This European Standard was approved by CENELEC on 2015-04-14. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any a
7、lteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other langu
8、age made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the
9、Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
10、 Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means res
11、erved worldwide for CENELEC Members. Ref. No. EN 62493:2015 E BS EN 62493:2015EN 62493:2015 - 2 - Foreword The text of document 34/222/FDIS, future edition 2 of IEC 62493, prepared by IEC/TC 34 “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN
12、 62493:2015. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016-01-14 latest date by which the national standards conflicting with the document have to be withdrawn (do
13、w) 2018-04-14 This document supersedes EN 62493:2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of t
14、he International Standard IEC 62493:2015 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: CISPR 15:2013 NOTE Harmonized as EN 55015:2013 (not modified). CISPR 16-1-2 N
15、OTE Harmonized as EN 55016-1-2. CISPR 16-4-2:2003 NOTE Harmonized as EN 55016-4-2:2004 1)(not modified). IEC 62226-2-1:2004 NOTE Harmonized as EN 62226-2-1:2005 (not modified). 1)Superseded by EN 55016-4-2:2011 (CISPR 16-4-2:2011). BS EN 62493:2015- 3 - EN 62493:2015 Annex ZA (normative) Normative r
16、eferences to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, th
17、e latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in
18、 this annex is available here: www.cenelec.eu Publication Year Title EN/HD Year IEC 62209-2 2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absor
19、ption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) EN 62209-2 2010 IEC 62232 2011 Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposur
20、e - - IEC 62311 (mod) 2007 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) EN 62311 2008 IEC 62479 (mod) 2010 Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions
21、 related to human exposure to electromagnetic fields (10 MHz to 300 GHz) EN 62479 2010 CISPR 16-1-1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus EN 55016-1-1 - BS EN 62493:2015
22、2 IEC 62493:2015 IEC 2015 CONTENTS FOREWORD . 6 INTRODUCTION . 8 1 Scope 9 2 Normative references 9 3 Terms, definitions, physical quantities, units and abbreviations . 10 3.1 Terms and definitions 10 3.2 Physical quantities and units . 12 3.3 Abbreviations 13 4 Limits 13 4.1 General . 13 4.2 Uninte
23、ntional radiating part of lighting equipment 14 General . 14 4.2.1Lighting equipment deemed to comply with the Van der Hoofden test 4.2.2without testing . 14 Application of limits 14 4.2.34.3 Intentional radiating part of lighting equipment 14 5 General requirements Van der Hoofden test 15 5.1 Measu
24、rand 15 5.2 Supply voltage and frequency . 15 5.3 Measurement frequency range 16 5.4 Ambient temperature. 16 5.5 Measurement equipment requirements 16 5.6 Measurement instrumentation uncertainty . 17 5.7 Test report 17 5.8 Evaluation of results . 18 6 Measurement procedure for the Van der Hoofden te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN624932015ENASSESSMENTOFLIGHTINGEQUIPMENTRELATEDTOHUMANEXPOSURETOELECTROMAGNETICFIELDPDF

链接地址:http://www.mydoc123.com/p-721398.html