《EN 61003-2-2009 en Industrial-process control systems - Instruments with analogue inputs and two- or multi-state outputs - Part 2 Guidance for inspection and routine testing (Remai.pdf》由会员分享,可在线阅读,更多相关《EN 61003-2-2009 en Industrial-process control systems - Instruments with analogue inputs and two- or multi-state outputs - Part 2 Guidance for inspection and routine testing (Remai.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Industrial-process control systems Instruments with analogue inputs and two- ormulti-state outputsPart 2: Guidance for inspection and routine testingBS EN 61003-2:2009National forewordThis British Standard is the UK implementation of EN 61003-2:2009. It isidentical to IEC 61003-2:2009.The UK partici
2、pation in its preparation was entrusted by Technical CommitteeGEL/65, Measurement and control, to Subcommittee GEL/65/2, Elements ofsystems.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary
3、provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 61815 4ICS 25.040.40Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee
4、 on 31 May 2010.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61003-2:2009EUROPEAN STANDARD EN 61003-2 NORME EUROPENNE EUROPISCHE NORM October 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Eu
5、ropisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61003-2:2009 E ICS 25.040.40 English version Industrial-process control s
6、ystems - Instruments with analogue inputs and two- or multi-state outputs - Part 2: Guidance for inspection and routine testing (IEC 61003-2:2009) Processus industriels - Instruments avec entres analogiques et sorties deux ou plusieurs tats - Partie 2: Guide pour les inspections et les essais indivi
7、duels de srie (CEI 61003-2:2009) Systeme der industriellen Prozessleittechnik - Gerte mit analogen Eingngen und Zwei- oder Mehrpunktverhalten - Teil 2: Leitfaden fr Funktionskontrolle und Serienprfung (IEC 61003-2:2009) This European Standard was approved by CENELEC on 2009-09-01. CENELEC members ar
8、e bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to
9、the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the
10、 same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands,
11、Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 61003-2:2009EN 61003-2:2009 - 2 - Foreword The text of document 65B/703/CDV, future edition 1 of IEC 61003-2, prepared by SC 65B, Devices Relative humidity from 45 % to 75 %; Atmospheric p
12、ressure from 86 kPa to 106 kPa; BS EN 61003-2:200961003-2 IEC:2009 7 Electromagnetic field value to be stated if relevant. The maximum rate of change of ambient temperature permissible during any test shall be 1 C in 10 min and less than 3 C/h. 5.2.2 Supply conditions Electrical supply: Rated voltag
13、e 1 %; Rated frequency 1 %; Harmonic distortion (a.c. supply) less than 5 %; Ripple (d.c. supply) less than 0,1 %. Pneumatic supply: Rated pressure 3 %; Supply air temperature ambient temperature 2 C; Supply air humidity dew point at least 10 C below devices body temperature; Oil and dust content oi
14、l: less than 1 106by weight; dust: absence of particles greater than 3 m. 5.3 Tests under reference conditions 5.3.1 General All tests given in 6.1 and 6.3 of IEC 61003-1 should be carried out. Multi-state instruments should supplement the tests given in Clause 7 of IEC 61003-1. The detailed test pr
15、ocedures are given in IEC 61298-2. 5.3.2 Set point 5.3.2.1 Set point adjustable and measurable or indicated The set point shall be tested at value of 10 %, 50 % and 90 % at least, the 50 % value being taken last. The measurement or indication accuracy shall be determined at five points approximately
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6100322009ENINDUSTRIALPROCESSCONTROLSYSTEMSINSTRUMENTSWITHANALOGUEINPUTSANDTWOORMULTISTATEOUTPUTSPART2GUIDANCEFORINSPECTIONANDROUTINETESTINGREMAIPDF

链接地址:http://www.mydoc123.com/p-719314.html