EN 60835-3-14-1996 en Methods of Measurement for Equipment Used in Digital Microwave Radio Transmission Systems Part 3 Measurements on Satellite Earth Stations Section 14 Earth Sta.pdf
《EN 60835-3-14-1996 en Methods of Measurement for Equipment Used in Digital Microwave Radio Transmission Systems Part 3 Measurements on Satellite Earth Stations Section 14 Earth Sta.pdf》由会员分享,可在线阅读,更多相关《EN 60835-3-14-1996 en Methods of Measurement for Equipment Used in Digital Microwave Radio Transmission Systems Part 3 Measurements on Satellite Earth Stations Section 14 Earth Sta.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、lb2Libb 0587151 545 BRITISH STANDARD Methods of measurement for equipment used in digital microwave radio transmission systems Part 3. Measurements on satellite earth stations Section 3.14 Earth stations for satellite news gathering (SNG) c * Kn The European Standard EN 60835-314 : 1996 has the stat
2、us of a British Standard ICs 33.060.30 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHI LAW it should then be confirmed that the received cross-polarized signal level is lower than the level correspond- ing to the specified cross-polarization discrimination. If required, a test sig
3、nal is then transmitted from the SNG terminal to the satellite, under the direction of the cooperating earth station, and the correct antenna alignment of the SNG terminal is verified by confirming that the cross-polarized signal level received by the Co-operating earth station is lower than the lev
4、el corresponding to the specified cross- polarization discrimination. NOTE - This measurement should be carried out at a frequency at which no other cross-polar signal is transmitted. 5.1.3 Carrier frequencies See IEC 835-1 -2. The frequency of the carrier transmitting the vision and sound signals s
5、hall be measured by switching off the modulation. Measurements shall be carried out at specified steps of the frequency-agile up-converter 1, and the deviation between the measured and nominal frequencies shall be ascertained. The microwave counter for this measurement shall be connected to the low-
6、level output of the coupler following the HPA, as shown in figure 2. 5.1.4 RF output power See IEC 835-1-2. A power meter should be connected to the r.f. output port by disconnecting the antenna waveguide. For an SNG terminal with digital modulation, the output power of the carrier shall be measured
7、, and, if required, the mean output power of the signal modulated, preferably by a pseudo-noise bit sequence. For an SNG terminal with analogue modulation, the unmodulated carrier power shall be measured. The range of output power adjustment, if applicable, should also be ascertained. . When multipl
8、e carriers are transmitted simultaneously from a single power amplifier, the power of each carrier shall be measured separately by using a calibrated spectrum analyzer. 5.1.5 RF output spectrum See IEC 835-1-2. With a spectrum analyzer connected to the low-level test output port of the coupler shown
9、 in figure 2, the spectrum shall be measured at the rated output power, with the operational carrier modulated by a suitable test signal. A mask should be applied to the spectrum analyzer screen to ascertain that spectrum lines are confined within specified limits. = lb24bb9 05871bL 479 =- Page 7 EN
10、 60835-3-14 : 1996 5.1.6 Radiation hazards The purpose of this measurement is to ensure that the r.f. electromagnetic fields radiated from the SNG equipment do not constitute a potential hazard to operators, or to the general public. The SNG installation shall be approached from all accessible direc
11、tions, and measurements shall be taken of the power flux density by using a calibrated test antenna connected to a receiver (hazard meter). All locations where a specified power flux density is exceeded shall be identified. 5.1 .? See the future IEC 835-3-13. Off-axis EIRP (equivalent isotropically
12、radiated power) density 5.1.8 G/T of the monitoring system See IEC 835-3-7. The purpose of measuring this parameter is to ascertain that the monitored picture and sound signals characterize, to a sufficient extent, the uplinked picture and sound signals. 5.2 Baseband parameters 5.2.1 Interface param
13、eters of the sound/vision equipment See IEC 835-1-2. 5.2.2 Control functions - antenna alignment, azimuth and elevation. including antenna tracking, if applicable; - polarization; - carrier power; - carrier frequency (by synthesizer tuning); - transmitter output power (onioff). In a basic flyaway sy
14、stem, all these functions may be manually controlled. In an SNG vehicle, some of these functions, for example antenna and polarization adjustments, may be operated by remote control. It should be verified that the above control functions operate as specified. 5.2.3 Video/sound parameters The video a
15、nd sound parameters shall be tested in a transmitterlreceiver loop utilizing the loop test translator shown in figure 2. A test receiver of suitable quality shall be applied if these parameters cannot be accurately assessed in the transmitter/receiver loop because of the insufficient quality of the
16、SNG terminal receiving part. 5.2.4 Duplex sound communication channels These channels shall also be checked in a transmitterlreceiver loop utilizing the loop test translator. A functional check shall be carried out by initiating a call, and verifying that connection with the called party has been es
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN608353141996ENMETHODSOFMEASUREMENTFOREQUIPMENTUSEDINDIGITALMICROWAVERADIOTRANSMISSIONSYSTEMSPART3MEASUREMENTSONSATELLITEEARTHSTATIONSSECTION14EARTHSTAPDF

链接地址:http://www.mydoc123.com/p-719026.html