EN 60598-2-24-2013 en Luminaires - Part 2-24 Particular requirements - Luminaires with limited surface temperatures.pdf
《EN 60598-2-24-2013 en Luminaires - Part 2-24 Particular requirements - Luminaires with limited surface temperatures.pdf》由会员分享,可在线阅读,更多相关《EN 60598-2-24-2013 en Luminaires - Part 2-24 Particular requirements - Luminaires with limited surface temperatures.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationLuminairesPart 2-24: Particular requirements Luminaires with limited surface temperaturesBS EN 60598-2-24:2013National forewordThis British Standard is the UK implementation of EN 60598-2-24:2013. It isidentical to IEC 60598-2-24:2013. It supersedes BS EN 60598-2-24:1999,whi
2、ch will be withdrawn on 24 July 2016.The UK participation in its preparation was entrusted by TechnicalCommittee CPL/34, Lamps and Related Equipment, to SubcommitteeCPL/34/4, Luminaires.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication
3、does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN 978 0 580 72867 9ICS 29.140.40 Compliance with a British Standard cannot confer immunity fromle
4、gal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 August 2013.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60598-2-24:2013EUROPEAN STANDARD EN 60598-2-24 NORME EUROPENNE EUROPISCHE NORM
5、 August 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means
6、reserved worldwide for CENELEC members. Ref. No. EN 60598-2-24:2013 E ICS 29.140.40 Supersedes EN 60598-2-24:1998 English version Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures (IEC 60598-2-24:2013) Luminaires - Partie 2-24: Exigences particulires - Lu
7、minaires avec surfaces tempratures limites (CEI 60598-2-24:2013) Leuchten Teil 2-24: Besondere Anforderungen Leuchten mit begrenzter Oberflchentemperatur (IEC 60598-2-24:2013) This European Standard was approved by CENELEC on 2013-07-24. CENELEC members are bound to comply with the CEN/CENELEC Inter
8、nal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any
9、CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the offi
10、cial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg,
11、Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 60598-2-24:2013EN 60598-2-24:2013 - 2 - Foreword The text of document 34D/1094/FDIS, future edition 2 of IEC 60598-2-24, prepared by SC 34D “Luminaires“ of
12、IEC/TC 34 “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60598-2-24:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endors
13、ement (dop) 2014-04-24 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-07-24 This document supersedes EN 60598-2-24:1998. EN 60598-2-24:2013 includes the following significant technical changes with respect to EN 60598-2-24:1998: a) change of
14、 required degree of protection from IP6X to IP4X to harmonize with the international wiring rules; b) temperature limits introduced for glass surface of any light source exposed to risk of dust. This standard is to be read in conjunction with EN 60598-1, Luminaires Part 1: General requirements and t
15、ests. NOTE In this standard, the following print types are used: requirements: in roman type. test specifications: in italic type. notes: in small roman type. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shal
16、l not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the International Standard IEC 6059
17、8-2-24:2013 was approved by CENELEC as a European Standard without any modification. BS EN 60598-2-24:2013- 3 - EN 60598-2-24:2013 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are
18、normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified
19、by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60364-4-42 - Low voltage electrical installations - Part 4-42: Protection for safety - Protection against thermal effects HD 60364-4-42 - IEC 60598-1 - Luminaires - Part 1: General requirem
20、ents and tests EN 60598-1 - ISO 4225 1994 Air quality - General aspects - Vocabulary - - BS EN 60598-2-24:2013 2 60598-2-24 IEC:2013 CONTENTS 24.1 Scope 5 24.2 Normative references 5 24.3 General test requirements 5 24.4 Terms and definitions 5 24.5 Classification of luminaires 6 24.6 Marking . 6 24
21、.7 Construction 6 24.8 Creepage distances and clearances . 7 24.9 Provision for earthing . 7 24.10 Terminals and electrical connections 7 24.11 External and internal wiring 7 24.12 Protection against electric shock 7 24.13 Endurance test and thermal test. 7 24.13.1 Temperature limits normal operatio
22、n . 7 24.13.2 Temperature limits abnormal operation . 8 24.13.3 Temperature limits fault conditions . 8 24.14 Resistance to dust, solid objects and moisture . 8 24.15 Insulation resistance and electric strength 8 24.16 Resistance to heat, fire and tracking 8 Figure 1 Symbol for luminaires with limit
23、ed surface temperatures . 6 BS EN 60598-2-24:201360598-2-24 IEC:2013 5 LUMINAIRES Part 2-24: Particular requirements Luminaires with limited surface temperatures 24.1 Scope This part of the IEC 60598 series specifies requirements for luminaires intended for use where the necessity of limited tempera
24、ture on the outer surface exists, due to the risk of thermal effects, combustion or degradation of materials but where the risk of explosion in the atmosphere does not exist. The luminaires are for use with electric light sources on supply voltages not exceeding 1 000 V. This standard specifically e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN605982242013ENLUMINAIRESPART224PARTICULARREQUIREMENTSLUMINAIRESWITHLIMITEDSURFACETEMPERATURESPDF

链接地址:http://www.mydoc123.com/p-718399.html