EN 60312-1-2017 en Vacuum cleaners for household use - Part 1 Dry vacuum cleaners - Methods for measuring the performance.pdf
《EN 60312-1-2017 en Vacuum cleaners for household use - Part 1 Dry vacuum cleaners - Methods for measuring the performance.pdf》由会员分享,可在线阅读,更多相关《EN 60312-1-2017 en Vacuum cleaners for household use - Part 1 Dry vacuum cleaners - Methods for measuring the performance.pdf(96页珍藏版)》请在麦多课文档分享上搜索。
1、Vacuum cleaners for household usePart 1: Dry vacuum cleaners Methods for measuring the performance (IEC 60312-1:2010, modified + A1:2011, modified)BS EN 603121:2017 Incorporating corrigendum December 2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 60312-1:2
2、013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 60312-1:2013. It is derived fromIEC 60312-1:2010, incorporating amendment 1:2011. Together with BS EN 62885-3 it supersedes BS EN 60312:2008, which will be withdrawn upon publication ofBS EN 62885-3.The CENELEC
3、 common modifications have been implemented at the appropriateplaces in the text. The start and finish of each common modification is indicated in thetext by .The start and finish of text introduced or altered by amendment is indicated in the textby tags. Tags indicating changes to IEC text carry th
4、e number of the IEC amendment. Forexample, text altered by IEC amendment 1 is indicated by .BSI, as a member of CENELEC, is obliged to publish BS EN 60312-1 as a British Standard.However, attention is drawn to the fact that the UK committee voted against itsapproval as a European standard.The princi
5、pal reason is that parts of EN 60312-1:2013 are not using the same formulaeor the same methods given in the draft European Commission Communication on theMeasurement Methods to be used for Vacuum Cleaner Energy Label and Ecodesign. TheUK committee requested that modifications to Clauses 5.2.3 and 5.
6、3.4 bring EN 60312-1into alignment with the European Commissions Annex on measurement and calculationmethods, set out in draft Ecodesign and Energy labelling Regulations, which addressesfull head width for pick up testing and the calculations for energy efficiency. Thisconcern is only relevant to th
7、e CENELEC implementation of IEC 60312-1.The UK committee also advises users that Clause 4.Z1, regarding a reference vacuumcleaner system, including its calibration and use, is, in the opinion of the committee, notsufficiently defined and therefore may lead to high repeatability and reproducibilityva
8、riations.The UK committee also notes that due to the modification to Clause 5.11.3, and omissionof clauses 5.11.4 and 5.11.5 by CENELEC common modification, EN 60312-1 does notreflect the measurement methods agreed at IEC, creating divergence, and will reducethe reliability, accuracy and reproducibi
9、lity of the Filtration Efficiency of the VacuumCleaner (Dust Re-emission) test method.An issue that has not been addressed by the CENELEC implementation of IEC 60312-1is that further development of the Wilton carpet specification is required, as at time ofpublication there are currently high reprodu
10、cibility variations between carpet batches.The UK participation in its preparation was entrusted by Technical Committee CPL/59,Performance of household electrical appliances, to Subcommittee CPL/59/6, Floortreatment appliances.A list of organizations represented on this subcommittee can be obtained
11、on requestto its secretary.This publication does not purport to include all the necessary provisions of a contract.Users are responsible for its correct application. The British Standards Institution 2015Published by BSI Standards Limited 2015ISBN 978 0 580 90059 4ICS 97.080Compliance with a British
12、 Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy andStrategy Committee on 30 September 2013.Amendments/corrigenda issued since publicationDate Text affected30 April 2015 Correction to supersession details in Natio
13、nal ForewordEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORMEN 60312-1 February 2017ICS 97.080 Supersedes EN 60312-1:2013English VersionVacuum cleaners for household use - Part 1: Dry vacuumcleaners - Methods for measuring the performance(IEC 60312-1:2010 , modified + A1:2011 , modified)Aspirateurs
14、 de poussire usage domestique - Partie 1:Aspirateurs a sec - Mthodes de mesure de laptitude la fonction (IEC 60312-1:2010 , modifie + A1:2011 , modifie) Staubsauger fr den Hausgebrauch - Teil 1: Trockensauger - Prfverfahren zur Bestimmung der Gebrauchseigenschaften(IEC 60312-1:2010 , modifiziert + A
15、1:2011 , modifiziert)This European Standard was approved by CENELEC on 2017-01-02. CENELEC members are bound to comply with the CEN/CENELECInternal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists a
16、nd bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under
17、the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has thesame status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia
18、, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,Switzerland, Turkey and the United Kingdom.European Committe
19、e for Electrotechnical StandardizationComit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC M
20、embers.Ref. No. EN 60312-1:2017 ENational forewordThis British Standard is the UK implementation of EN 603121:2017. It is derived from IEC 603121:2010, incorporating amendment 1:2011. It supersedes BS EN 603121:2013 which will be withdrawn on 2 January 2020.The CENELEC common modifications have been
21、 implemented at the appropriate places in the text. The start and finish of each common modification is indicated in the text by .The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to IEC text carry the number of the IEC amendmen
22、t. For example, text altered by IEC amendment 1 is indicated by .The UK participation in its preparation was entrusted to Technical Committee CPL/59/6, Floor treatment appliances.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does n
23、ot purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limited 2017ISBN 978 0 580 98690 1ICS 97.080Compliance with a British Standard cannot confer immunity from legal obli
24、gations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2017.Amendments/corrigenda issued since publicationDate Text affected31 December 2017 Common modifications of EN 60312-1:2013 implemented in textBRITISH STANDARDBS EN 603121:20
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6031212017ENVACUUMCLEANERSFORHOUSEHOLDUSEPART1DRYVACUUMCLEANERSMETHODSFORMEASURINGTHEPERFORMANCEPDF

链接地址:http://www.mydoc123.com/p-717832.html