EN 60094-2-1995 en Magnetic Tape Sound Recording and Reproducing Systems Part 2 Calibration Tapes《磁带录音和复制装置 第2部分 校准带( IEC 94-2-1994)》.pdf
《EN 60094-2-1995 en Magnetic Tape Sound Recording and Reproducing Systems Part 2 Calibration Tapes《磁带录音和复制装置 第2部分 校准带( IEC 94-2-1994)》.pdf》由会员分享,可在线阅读,更多相关《EN 60094-2-1995 en Magnetic Tape Sound Recording and Reproducing Systems Part 2 Calibration Tapes《磁带录音和复制装置 第2部分 校准带( IEC 94-2-1994)》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 CENELEC ENxb0094-2 95 = 3404583 OLb5384 140 BRITISH STANDARD Magnetic tape sound recording and reproducing systems Part 2. Calibration tapes The European Standard EN 60094-2 : 1995 has the status of a British Standard Product code 00630175 ICs 33.160.30 BS EN 600942 : 1996 BS 6288 : Part 2 : 1995 I
2、EC 942 : 1994 (Imluding corrigendum, March 1995, to IEC 942 : 1994) CENELEC EN*b0094-2 95 m 3404583 OLb5385 087 m AmdNo. Date BS EN 600942 : 1996 Text afected Committees responsible for this British Standard The preparation of this British Standard was entnisted to Technical Committee EPy60, Recordi
3、ng, upon which the following bodies were represented: Association of professional Recording SeMces Ltd. Audio Engineering Society British Broadcasting Corporation British Jhemabgraph, Sound and Television Society British Tape industry Association Federation of the Electronics industry ITVAssociaon (
4、TVA) National Counci for Educational Technology (NCET) Royal Photographic Society Royal Television Society This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards bard and comes into effect on 15 January
5、 O BSI 1996 1996 The following BSI references relate to the work on this standard: Committee reference EPUGO Draft for comment 90R2224 DC ISBN O 580 24955 7 CENELEC EN*b0094-2 95 W 3404583 0365386 TL3 W BS EN 600942 : 1996 Contents page Committees responsible Inside front cover National foreword ii
6、Foreword 2 Specification 1 Scope 3 2 Object 3 3 General requirements 3 4 5 6 Tapes for use at speeds of 38.1 cds (15 ids) and 19.05 cm/s (7 112 ds) Tapes for use at a speed of 9.53 cds (3 3/4 ids) 4 5 6 Tapes for use at a speed of 4.76 cds (1 718 ids) Annex A List of supplieis of calibration tapes o
7、f width 3.81 mm for use at a speed of 4.76 cds 7 O BSI 1996 i CENELEC EN*b0094-2 95 3404583 OLb5387 957 R BS EN 60094-2 : 1996 National foreword This British Standard has been prepared by Technical Committee EPU60 and is the English language version of EN 600942 : 1995 Magnetic tape sound recording
8、and repmducing systems Part 2 : Calibration tapes, published by the European Committee for Electrokchnical Standardization (CENELEC). It is identical with IEC 942 : 1994 and its corrigendum (March 1995), published by the International Electrotechnicd Commission (EX). The cross-reference of this stan
9、dard as Part 2 of the BS 6288 series has been retained to facilitate reference to other parts of the series. This British Standard supersedes BS EN 600942 : 1994 (BS 6288 : Part 2 : 1994), which is withdrawn. This edition does not reflect a full review or revision of the standard, which will be unde
10、rtaken in due course. BS 6288 consists of the following Parts: Part 1 (BS EN 600941) Part 2 (BS EN 600942) Part 3 Part 4 (BS EN 600944) Part 5 (BS EN 600945) Part 6 Part 7 (BS EN 600947) Part 8 Part 9 Part 10 Part 11 Cross-references Publication referred to IEC 941 : 1981) ISOR 266 : 19632) Specific
11、ation forgenerai conditions and requirmts Specification for calibration tapes Methods of masuring the chamtemstics of recording and reproducing equiprnent for sound on magnetic tape Mechanical magnetic tape properties Specification for electrical magnetic tape properties Sp 2) azimuth; 3) amplitude/
12、frequency response. Each section shall be recorded at a recording angle of 90“ i 1. relative to the edge of the tape. Over the frequency range used, all of the octave frequencies of the preferred ISO/R 266 frequencies, relative to 1 O00 Hz, shall be used. Additional frequencies shall be used from th
13、e one-third octave. If further frequencies are required, one-sixth octave shall be applied. Each section shall be announced and the official IEC languages are preferred. At the beginning of the tape, the standard tape speed to which the calibration refers, the characteristic to which the tape has be
14、en recorded and the date of recording shall be announced, for instance “IEC calibration tape for 38,l cm/s (15 inis) recorded to a 35 ps time constant in accordance with IEC Publication 94, first edition“. CENELEC EN*bOJJS9-2 75 = 3404583 0365373 380 W Page 4 EN 60094-2 : 1995 An announcement at the
15、 beginning of each section shall specify the content of that section: for the reference level section, the short-circuit flux per unit track width; and for the other sections, the short-circuit flux level relative to that of the reference level section; for example: - Reference level section: - Azim
16、uth section: 1 O00 Hz at 320 nWb1m. 1 O00 Ht at minus 10 dB. - Amplitude/frequency response section: 1 O00 Hz at minus 20 dB. Announcements shall be recorded at a peak level slightly lower than the recorded signals in that section. An instruction sheet shall accompany each tape. It shall specify the
17、 relevant IEC publi- cations and the date of production of the calibration tape and shall include at least a description of the contents of the tape. 4 lapes for use at speeds of 38,1 cmls (15 In1s) and 19,05 cm1s (7 112 Ink) 4.1 Reference level section A signal at the reference frequency, preferabl
18、y of 1 O00 i 30 Hz, shall be recorded at a specified short-circuit flux per unit track width, preferably of 320 nWb/m, and having a distortion of less than or equal to 1 %. The duration of the signal shall be at least 30 s. The tolerance of the reference flux of commercially available calibration ta
19、pes shall not exceed 15 %. 4.2 Azimuth section Signals of 1 O00 Hz and 10 O00 Hz shall be recorded. The 1 O00 Hr signal shall be recorded at a specified short-circuit flux per unit track width, preferably of 100 nWb1m. The duration of the signal shall be at least 10 s and 60 s respectively. 4.3 Ampl
20、itude/frequency response section The following signals shall be recorded, preferably in the order shown. The first 1 O00 Hz signal, recorded at a specified short-circuit flux per unit track width of at least 32 nWblm, shall be the reference signal. Each signal shall have a duration of at least 10 s.
21、 The maxi- mum deviation in the frequencies shown shall be k3 %. 1 O00 Hz, 313 Hz. 40 Hz, 50 Hz, 63 Hz. 80 Hz*, 100 Hz, 125 Hz. 250 Hz, 500 Hz, 1 O00 Hz. 2 O00 Hz, 4 O00 Hz, 6 300 Hz. 8 O00 Hz, 10 O00 Hz. 12 500 Hz, 14 O00 Hz. 16 O00 Hz, 18 O00 Hz. 20 O00 Hz, 1 O00 Hz. Optional CENELEC EN*b0074-2 75
22、 3404583 03b5372 217 Page 5 EN 60094-2 : 1995 The deviation of the recorded levels, relative to the short-circuit flux response curve as given in IEC 94-1, shall not exceed I0.5 dB for signals up to and including 10 O00 Hz nor il dB for signals over 10 O00 Hz. The level fluctuations up to and includ
23、ing 10 O00 Hz shall not exceed 0,5 dB and shall not exceed 1 dB over 10 O00 Hz, measured with an appropriate track per reproduction channel. 5 Tapes for use at a speed of 933 cmis (3 314 Ink) 5.1 Reference level section A signal at the reference frequency, preferably of 315 f 10 Hz, shall be recorde
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6009421995ENMAGNETICTAPESOUNDRECORDINGANDREPRODUCINGSYSTEMSPART2CALIBRATIONTAPES 磁带 录音 复制 装置 部分 校准

链接地址:http://www.mydoc123.com/p-717602.html