EN 50536-2011 en Protection against lightning - Thunderstorm warning systems (Incorporating corrigendum June 2011 Incorporates Amendment A1 2012)《雷电防护 雷暴警告系统(包括2011年6月勘误表)》.pdf
《EN 50536-2011 en Protection against lightning - Thunderstorm warning systems (Incorporating corrigendum June 2011 Incorporates Amendment A1 2012)《雷电防护 雷暴警告系统(包括2011年6月勘误表)》.pdf》由会员分享,可在线阅读,更多相关《EN 50536-2011 en Protection against lightning - Thunderstorm warning systems (Incorporating corrigendum June 2011 Incorporates Amendment A1 2012)《雷电防护 雷暴警告系统(包括2011年6月勘误表)》.pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50536:2011+A1:2012Protection against lightning Thunderstorm warning systemsIncorporating corrigendum June 2011BS EN 50536:2011+A1:2012National forewordThis British Standard
2、 is the UK implementation of EN 50536:2011+A1:2012, incorporating corrigendum June 2011. It supersedes BS EN 50536:2011, which is withdrawn.The start and finish of text introduced or altered by corrigendum is indicated in the text by tags. Text altered by CENELEC corrigendum June 2011 is indicated i
3、n the text by .The start and finish of text introduced or altered by amendment is the number of the CENELEC amendment. For example, text altered by CENELEC amendment A1 is indicated by !“.The UK participation in its preparation was entrusted to Technical Committee GEL/81, Protection against lightnin
4、g.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013. Published by BSI Sta
5、ndards Limited 2013 ISBN 978 0 580 78808 6 ICS 07.060 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2011.Amendments/corrigenda issued since publicati
6、onDate Text affected31 July 2011 Implementation of CENELEC corrigendum June 201128 February 2013 Implementation of CENELEC amendment A1:2012BRITISH STANDARDindicated in the text by tags. Tags indicating changes to CENELEC text carry EUROPEAN STANDARD EN 50536:2011+A1NORME EUROPENNE EUROPISCHE NORM C
7、ENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved world
8、wide for CENELEC members. Ref. No. EN 50536:2011 E ICS 07.060 English version Protection against lightning - Thunderstorm warning systems Protection contre la foudre - Dispositif de dtection dorage Blitzschutz - Gewitterwarnsysteme This European Standard was approved by CENELEC on 2011-02-14. CENELE
9、C members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on app
10、lication to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secreta
11、riat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Mal
12、ta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Incorporating corrigendum June 2011October 2012 - 2 - Foreword This European Standard was prepared by the Technical Committee CENELEC TC 81X, Lightning protection. The text
13、of the draft was submitted to the formal vote and was approved by CENELEC as EN 50536 on 2011-02-14. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such pat
14、ent rights. The following dates are proposed: latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-02-14 latest date by which the national standards conflicting with the amendment have to be withdrawn
15、 (dow) 2014-02-14 Foreword to amendment A1 This document (EN 50536:2011/A1:2012) has been prepared by CLC/TC 81X “Lightning protection“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by en
16、dorsement (dop) 2013-09-19 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2015-09-19 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held respo
17、nsible for identifying any or all such patent rights. BS EN 50536:2011+A1:2012 EN 50536:2011+A1:2012 (E)- 3 - Contents Introduction - 6 -1 General - 7 -1.1 Object - 7 -1.2 Scope . - 7 -2 Normative references - 8 -3 Terms and definitions . - 8 -4 Thunderstorm phases and detectable phenomena for alarm
18、ing . - 11 -4.1 Introduction - 11 -4.2 Phase 1 Initial phase (Cumulus stage) . - 11 -4.3 Phase 2 Growth phase . - 12 -4.4 Phase 3 Mature phase . - 12 -4.5 Phase 4 Dissipation phase . - 12 -5 Classification of thunderstorm detection devices and their properties - 12 -6 Alarm method . - 14 -6.1 Genera
19、l - 14 -6.2 Areas . - 14 -6.3 Alarm triggering . - 15 -6.4 Alarm information delivery . - 17 -7 Installation and maintenance . - 17 -8 Alarm evaluation - 17 -8.1 General - 17 -8.2 Evaluation of systems by using lightning location data . - 19 -8.3 Fine tuning of TWS by processing archived data - 19 -
20、9 Thunderstorms Warning Systems application guide - 20 -9.1 General - 20 -9.2 Procedure - 20 -Annex A (informative) Overview of the lightning phenomena - 23 -A.1 Origin of thunderclouds and electrification - 23 -A.2 Lightning phenomena - 24 -A.3 Electrical thunderstorm and lightning characteristics
21、useful for prevention . - 25 -Annex B (informative) Thunderstorm detection techniques . - 27 -B.1 Introduction - 27 -B.2 Detection techniques and parameters to qualify a sensor - 27 -B.3 Location techniques . - 28 -B.4 Thunderstorm detectors evaluation . - 30 -B.5 Choosing a thunderstorm detection s
22、ystem - 30 -Annex C (informative) Thunderstorms Warning Systems application examples . - 31 -C.1 Example n 1 TELECOMUNICATION TOWER . - 31 -C.2 Example n 2 GOLF COURSE . - 33 -C.3 Example n 3 WIND TURBINE FARM (including its maintenance) . - 35 -Annex D (informative) Catalogue of possible recommende
23、d preventive actions to be taken . - 38 -Annex E (informative) Example of TWS evaluation on a wind turbine site - 41 -Bibliography . - 43 -BS EN 50536:2011+A1:2012 EN 50536:2011+A1:2012 (E)- 4 - Figures Figure 1 Examples of different target shapes . - 14 -Figure 2 Example of the distribution of the
24、coverage area (CA), the monitoring area (MA) and the target area . - 15 -Figure 3 Example of an alarm. a) Locations of the lightning related events (LRE) in the defined areas (coverage area CA, monitoring area MA, surrounding area SA, and target ); b) temporal occurrence of the lightning related eve
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN505362011ENPROTECTIONAGAINSTLIGHTNINGTHUNDERSTORMWARNINGSYSTEMSINCORPORATINGCORRIGENDUMJUNE2011INCORPORATESAMENDMENTA12012

链接地址:http://www.mydoc123.com/p-717263.html