EN 572-2-2012 en Glass in building - Basic soda lime silicate glass products - Part 2 Float glass《建筑用玻璃 基本钠钙玻璃制品 浮法玻璃》.pdf
《EN 572-2-2012 en Glass in building - Basic soda lime silicate glass products - Part 2 Float glass《建筑用玻璃 基本钠钙玻璃制品 浮法玻璃》.pdf》由会员分享,可在线阅读,更多相关《EN 572-2-2012 en Glass in building - Basic soda lime silicate glass products - Part 2 Float glass《建筑用玻璃 基本钠钙玻璃制品 浮法玻璃》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 572-2:2012Glass in building Basic sodalime silicate glass productsPart 2: Float glassBS EN 572-2:2012 BRITISH STANDARDNational forewordThis British Standard is the UK imple
2、mentation of EN 572-2:2012. Itsupersedes BS EN 572-2:2004 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/520/1, Basic and transformed glass products.A list of organizations represented on this committee can beobtained on request to its secretary.This
3、 publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 76524 7ICS 81.040.20Compliance with a British Standard cannot confer immu
4、nity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2012.Amendments issued since publicationDate Text affectedBS EN 572-2:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 572-2 July 2012 ICS 81.040.20 Sup
5、ersedes EN 572-2:2004English Version Glass in building - Basic soda lime silicate glass products - Part 2: Float glass Verre dans la construction - Produits de base : verre de silicate sodo-calcique - Partie 2: Glace Glas im Bauwesen - Basiserzeugnisse aus Kalk-Natronsilicatglas - Teil 2: Floatglas
6、This European Standard was approved by CEN on 11 May 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical referen
7、ces concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN m
8、ember into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
9、France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHE
10、S KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 572-2:2012: EBS EN 572-2:2012EN 572-2:2012 (E) 2 Contents Page Foreword 31 Scope 42 Normative references
11、 43 Terms and definitions .44 Dimensional requirements 54.1 Thickness .54.1.1 General 54.1.2 Tolerances 64.2 Length, width and squareness .65 Quality requirements .75.1 General 75.2 Methods of observation and measurement 75.2.1 Optical faults 75.2.2 Visual faults 85.3 Acceptance levels 95.3.1 Optica
12、l faults 95.3.2 Spot faults 96 Designation . 10Annex A (normative) Method for measuring spot fault size (including halo) 11A.1 Conditions of observation . 11A.2 Measurement of the size of the spot fault including the halo 12Bibliography . 14BS EN 572-2:2012EN 572-2:2012 (E) 3 Foreword This document
13、(EN 572-2:2012) has been prepared by Technical Committee CEN/TC 129 “Glass in building”, the secretariat of which is held by NBN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2013, and
14、conflicting national standards shall be withdrawn at the latest by January 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This
15、document supersedes EN 572-2:2004. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. This edition is a revision of EN 572-2:2004. The main changes in this edition are: a) an enlargement of the scope to oversize plates;, b
16、) a new method of determination of squareness;, c) a new method of measurement for spot fault (including halo) and an adaptation of the related requirements. This European Standard “Glass in building Basic soda lime silicate glass products” consists of the following parts: Part 1: Definitions and ge
17、neral physical and mechanical properties; Part 2: Float glass; Part 3: Polished wired glass; Part 4: Drawn sheet glass; Part 5: Patterned glass; Part 6: Wired patterned glass; Part 7: Wired or unwired channel shaped glass; Part 8: Supplied and final cut sizes; Part 9: Evaluation of conformity/Produc
18、t standard. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
19、 France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 572-2:2012EN 572-2:2012 (E) 4 1 Scope This European Standard specifie
20、s dimensional and minimum quality requirements (in respect of optical and visual faults) for float glass, as defined in EN 572-1:2012, for use in building. This European Standard applies only to float glass supplied in jumbo sizes (see Note 1), split sizes (see Note 2) and oversize plates (see Note
21、3). NOTE 1 Jumbo sizes PLF (plateau largeur de fabrication) Bandmasse. NOTE 2 Split sizes DLF (dimension largeur de fabrication) Geteilte Bandmasse. NOTE 3 Oversize plates these are plates where the nominal length, H, is greater than 6 000 mm. These plates are produced to special order. EN 572-8 giv
22、es information on float glass in sizes (i.e. supplied and final cut sizes) other than those covered by this European Standard. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated referen
23、ces, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 572-1:2012, Glass in building Basic soda lime silicate glass products Part 1: Definitions and general physical and mechanical properties 3 Terms and defin
24、itions For the purposes of this document, the terms and definitions given in EN 572-1:2012 and the following apply. 3.1 length, H, and width, B defined with reference to the direction of draw of the float glass ribbon as shown in Figure 1 Key 1 direction of draw Figure 1 Relationship between length,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN57222012ENGLASSINBUILDINGBASICSODALIMESILICATEGLASSPRODUCTSPART2FLOATGLASS 建筑 玻璃 基本 玻璃制品 PDF

链接地址:http://www.mydoc123.com/p-712392.html