DLA MIL-DTL-9419 G-2008 SWITCH TOGGLE MOMENTARY FOUR-POSITION ON CENTER OFF GENERAL SPECIFICATION FOR《四位开中心关瞬时搬扭开关的一般规范》.pdf
《DLA MIL-DTL-9419 G-2008 SWITCH TOGGLE MOMENTARY FOUR-POSITION ON CENTER OFF GENERAL SPECIFICATION FOR《四位开中心关瞬时搬扭开关的一般规范》.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-9419 G-2008 SWITCH TOGGLE MOMENTARY FOUR-POSITION ON CENTER OFF GENERAL SPECIFICATION FOR《四位开中心关瞬时搬扭开关的一般规范》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions or questions on this document should be addressed to Defense Supply Center Columbus, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990), or emailed to switchdla.mil. Since contact information can change, you may want to verify the currency of this address information usi
2、ng the ASSIST Online database at http:/assist.daps.dla.mil AMSC N/A FSC 5930 INCH-POUND MIL-DTL-9419G 25 March 2008 SUPERSEDING MIL-DTL-9419F 1 June 2001 DETAIL SPECIFICATION SWITCH, TOGGLE, MOMENTARY, FOUR-POSITION ON, CENTER OFF, GENERAL SPECIFICATION FOR This specification is approved for use by
3、all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers four-position, momentary on, center off, positive action switch with free return to the off position. 1.2 Classification. Switches covered by this specification will be classified by type as indi
4、cated herein (see 3.1). Type I - Snap action, positive break operation. Type II - Nonpositive break operation. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sec
5、tions of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, wheth
6、er or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the so
7、licitation or contract. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-9419G 2 DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test Methods for Electronics and Electrical Component Parts. MIL-STD-810 - Environmental Engineering Considerations
8、and Laboratory Tests. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following
9、 documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI/NCSL Z540-1 - General Requirements for Calibration Laboratories and Mea
10、suring and Test Equipment. (Copies of these documents are available online at http:/dod.nssn.org or from the American National Standards Institute (ANSI), 11 West 42nd Street, New York, NY 10036-8002, telephone 212-642-4900, fax 212-302-1286.) INTERNATIONAL ORGANIZATION FOR STANDARDS (IS0) ISO 10012
11、-1 - Quality Assurance Requirements for Measuring Equipment - Part 1; Metrological Confirmation System for Measuring Equipment. (Copies of these documents are available online at http:/dod.nssn.org or from the American National Standards Institute (ANSI), 11 West 42nd Street, New York, NY 10036-8002
12、, telephone 212-642-4900, fax 212-302-1286.) SOCIETY OF AUTOMOTIVE ENGINEERS (SAE) SAE-AS50881 - Wiring, Aerospace Vehicle. (Copies of these documents are available online at http:/www.sae.org or from Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, Pennsylvania, 15096-0001) UNDE
13、RWRITERS LABORATORIES (UL), INCORPORATED UL94 - Test for Flammability of Plastic Materials for Parts in Devices and Appliances. (Copies of these documents are available online at http:/ or from the Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062-2002.) 2.4 Order of preceden
14、ce. In the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been o
15、btained. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-9419G 3 3. REQUIREMENTS 3.1 Specification sheets. The individual item requirements shall be as specified herein and in accordance with the applicable specification sheet. In the event o
16、f any conflict between the requirements of this specification and the specification sheet, the latter shall govern. 3.2 Qualification. Switches furnished under this specification, shall be products which are authorized by the qualifying activity for listing on the applicable qualified products list
17、at the time of award of contract (4.5 and 6.5). 3.3 Material. Material shall be as specified herein. When a definite material is not specified, a material shall be used which shall enable the switches to meet the performance requirements of this specification. Acceptance or approval of any constitue
18、nt material shall not be construed as a guarantee of acceptance of the finished product. 3.3.1 Metals. All metal parts, other than current-carrying parts, shall be of corrosion-resistant material, or shall be suitably plated to resist corrosion. 3.3.1.1 Ferrous material. Ferrous material shall not b
19、e used for current carrying parts. 3.3.1.2 Dissimilar metals. When dissimilar metals are used in intimate contact with each other, protection against electrolysis and corrosion shall be provided. The use of dissimilar metals which, in contact, tend toward active electrolytic corrosion (particularly
20、brass, copper, or steel used in contact with aluminum or aluminum alloy) is not acceptable. However, metal plating or metal spraying of dissimilar base metals to provide similar or suitable abutting surfaces is permitted. The use of dissimilar metals separated by a suitable insulating materiel is al
21、so permitted. For further guidance on the selection and use of metals see 6.7. 3.3.2 Insulating material. Molded material shall be used. Cellulose-filled phenolic shall not be used. 3.3.2.1 Plastic. The plastic material used in all external switch parts and enclosures shall be tested in accordance w
22、ith UL94 and classified as 94V-0; this requirement applies to all materials for external parts and enclosures regardless of whether the material used is acquired to a detail specification or not. 3.3.3 Protective treatment. Materials that are subject to deterioration when exposed to climatic and env
23、ironmental conditions likely to occur during service usage shall be protected against such deterioration in a manner that will in no way prevent compliance with the performance requirements of this specification. The use of any protective coating that will crack, chip, or scale with age or extremes
24、of climatic and environmental conditions shall be avoided. 3.4 Interface and physical dimensions. Switches shall be of sufficiently rugged construction to meet the requirements of this specification. Switches shall be direct acting, normally open type incorporating a positive action to assure good c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL9419G2008SWITCHTOGGLEMOMENTARYFOURPOSITIONONCENTEROFFGENERALSPECIFICATIONFOR 四位开 中心 瞬时 开关 一般

链接地址:http://www.mydoc123.com/p-691295.html