DIN EN 54-20-2009 Fire detection and fire alarm systems - Part 20 Aspirating smoke detectors (includes Amendment AC 2008) English version of DIN EN 54-20 2009-02《火灾探测和火灾报警系统 第20部分 .pdf
《DIN EN 54-20-2009 Fire detection and fire alarm systems - Part 20 Aspirating smoke detectors (includes Amendment AC 2008) English version of DIN EN 54-20 2009-02《火灾探测和火灾报警系统 第20部分 .pdf》由会员分享,可在线阅读,更多相关《DIN EN 54-20-2009 Fire detection and fire alarm systems - Part 20 Aspirating smoke detectors (includes Amendment AC 2008) English version of DIN EN 54-20 2009-02《火灾探测和火灾报警系统 第20部分 .pdf(82页珍藏版)》请在麦多课文档分享上搜索。
1、February 2009DEUTSCHE NORM English price group 24No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 13.220.20!$V)y“151068
2、6www.din.deDDIN EN 54-20Fire detection and fire alarm systems Part 20: Aspirating smoke detectors (includes Amendment AC:2008)English version of DIN EN 54-20:2009-02Brandmeldeanlagen Teil 20: Ansaugrauchmelder (enthlt Berichtigung AC:2008)Englische Fassung DIN EN 54-20:2009-02SupersedesDIN EN 54-20:
3、2006-09www.beuth.deDocument comprises 82 pagesDIN EN 54-20:2009-02 2 Start of validity This standard takes effect on 1 September 2006. It should be noted that, in Germany, CE conformity marking of construction products will be permitted once this standard has been listed in the Bundesanzeiger (Germa
4、n Federal Law Gazette) and from the date given therein. National foreword This standard has been prepared by Technical Committee CEN/TC 72 “Fire detection and fire alarm systems” (Secretariat: BSI, United Kingdom). The responsible German body involved in its preparation was the Normenausschuss Feuer
5、wehrwesen (Firefighting and Fire Protection Standards Committee), Technical Committee NA 031-02-01 AA Brandmelde- und Feueralarmanlagen. The system requirements and technical application rules for aspirating smoke detectors complying with this standard, for use in fire detection and alarm systems in
6、stalled in buildings, are specified in national Standards DIN 14675 and DIN VDE 0833-2 (VDE 0833-2) (see National Annex NA). Amendments This standard differs from DIN EN 54-20:2006-09 as follows: a) In the scope, 2ndparagraph, “not” has been replaced with “also” (Corrigendum EN 54-20:2006/AC:2008) b
7、) In the German version only, the heading of Table 5 has been modified. Previous editions DIN EN 54-20: 2006-09 National Annex NA (informative) Bibliography DIN 14675, Fire alarm systems Design and operation DIN VDE 0833-2 (VDE 0833-2), Alarm systems for fire, intrusion and hold up Part 2: Requireme
8、nts for fire alarm systems 89/106/EEC, Council Directive of 21 December 1988 on the approximation of the laws of the Member States relating to construction products Bauproduktengesetz BauPG, Gesetz ber das Inverkehrbringen von und den freien Warenverkehr mit Bauprodukten zur Umsetzung der Richtlinie
9、 89/106/EWG des Rates vom 21. Dezember 1988 zur Anglei-chung der Rechts- und Verwaltungsvorschriften der Mitgliedsstaaten ber Bauprodukte und anderer Rechts-akte der Europischen Gemeinschaften (Construction Products Act German Law implementing Council Directive 89/106/EEC of 21 December on the appro
10、ximation of laws, regulations and administrative provisions of the Member States relating to construction products) EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 54-20 June 2006 +AC November 2008 ICS 13.220.20 English version Fire detection and fire alarm systems Part 20: Aspirating smoke det
11、ectors Systmes de dtection et dalarme incendie Partie 20: Dtecteurs de fume par aspiration Brandmeldeanlagen Teil 20: Ansaugrauchmelder EN 54-20 was approved by CEN on 2006-05-18 and Corrigendum AC:2008 on 2008-11-19. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which st
12、ipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. The European Standards e
13、xist in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bod
14、ies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, and United Kingdom. E
15、UROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 54-20:2006 + AC:2008 E2
16、Contents Page Foreword. 4 1 Scope 6 2 Normative references . 6 3 Terms and definitions. 7 4 Symbols and abbreviations . 7 5 Requirements 8 5.1 Compliance 8 5.2 Individual visual alarm indication . 8 5.3 Connection of ancillary devices 8 5.4 Manufacturers adjustments 8 5.5 On site adjustment of respo
17、nse behaviour8 5.6 Response to slowly developing fires 9 5.7 Mechanical strength of the pipework 9 5.8 Hardware components and additional sensing elements in the sampling device 10 5.9 Airflow monitoring 10 5.10 Power supply. 11 5.11 Data. 11 5.12 Additional requirements for software controlled dete
18、ctors . 12 6 Tests. 13 6.1 General. 13 6.2 Repeatability 16 6.3 Reproducibility 17 6.4 Variation in supply parameters . 17 6.5 Dry heat (operational). 18 6.6 Cold (operational) . 19 6.7 Damp heat, steady state (operational) 20 6.8 Damp heat, steady state (endurance) . 21 6.9 Sulfer dioxide (SO2) cor
19、rosion (endurance). 22 6.10 Shock (operational). 23 6.11 Impact (operational) 24 6.12 Vibration, sinusoidal (operational) 25 6.13 Vibration, sinusoidal (endurance). 26 6.14 Electromagnetic compatibility (EMC) immunity tests. 27 6.15 Fire sensitivity. 28 7 Classification and designation 31 8 Marking
20、32 B.1 Fuel. 41 B.2 Hotplate 41 B.3 Arrangement 41 B.4 Heating rate . 42 B.5 End of test condition 42 B.6 Test validity criteria 42 C.1 Fuel. 44 DIN EN 54-20:2009-02 EN 54-20:2006+AC:2008 (E) Annex A (informative) Apparatus for Response Threshold Value (RTV) measurements . 33 Annex B (normative) Smo
21、uldering (pyrolysis) wood fire (TF2) 41 Annex C (normative) Reduced smouldering pyrolysis wood fires (TF2A and TF2B) 44 3 C.2 Hotplate 44 C.3 Arrangement 44 C.4 Heating rate . 45 C.5 End of test condition 45 C.6 Test validity criteria 45 D.1 Fuel. 47 D.2 Arrangement 47 D.3 Ignition . 48 D.4 End of t
22、est condition 48 D.5 Test validity criteria 48 E.1 Fuel. 50 E.2 Arrangement 50 E.3 Ignition . 51 E.4 End of test condition 51 E.5 Test validity criteria 52 F.1 Fuel. 53 F.2 Arrangement 53 F.3 Ignition . 53 F.4 End of test condition 53 F.5 Test validity criteria 53 G.1 Fuel. 55 G.2 Arrangement 55 G.3
23、 Ignition . 55 G.4 End of test condition 55 G.5 Test validity criteria 55 H.1 Fuel. 57 H.2 Arrangement 57 H.3 Ignition . 57 H.4 End of test condition 58 H.5 Test validity criteria 58 I.1 Fire test room 60 I.2 Ventilation system 62 K.1 General. 68 K.2 Airflow measuring with worst-case sampling device
24、 . 68 K.3 Airflow monitoring test with test pipe network 69 the EU Construction Products Directive 71 ZA.1 Scope and relevant clauses. 71 ZA.2 Procedures for the attestation of conformity of aspirating smoke detectors covered by this standard . 72 ZA.3 CE Marking and labelling and accompanying docum
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN54202009FIREDETECTIONANDFIREALARMSYSTEMSPART20ASPIRATINGSMOKEDETECTORSINCLUDESAMENDMENTAC2008ENGLISHVERSIONOFDINEN5420200902

链接地址:http://www.mydoc123.com/p-671642.html