DIN 38414-19-1999 German standard methods for the examination of water waste water and sludge - Sludge and sediments (group S) - Part 19 Determination of the steam-volatile organic.pdf
《DIN 38414-19-1999 German standard methods for the examination of water waste water and sludge - Sludge and sediments (group S) - Part 19 Determination of the steam-volatile organic.pdf》由会员分享,可在线阅读,更多相关《DIN 38414-19-1999 German standard methods for the examination of water waste water and sludge - Sludge and sediments (group S) - Part 19 Determination of the steam-volatile organic.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、ICS 13.060.50Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung Schlamm und Sedimente(Gruppe S) Teil 19: Bestimmung der wasserdampfflchtigen organischen Suren (S 19)In keeping with current practice in standards published by the International Organization for Standardization(IS
2、O), a comma has been used throughout as the decimal marker.ForewordThis standard has been jointly prepared by the Normenausschuss Wasserwesen (Water Practice StandardsCommittee) and Study Group Wasserchemie (Water Chemistry) of the Gesellschaft Deutscher Chemiker(German Chemists Society) (see Explan
3、atory notes).Expert assistance and specialized laboratories will be required to perform the analyses specified in thisstandard.Depending on the objective of the analysis, a check shall be made on case-by-case basis as to whether andto what extent additional conditions will have to be specified.Ref.
4、No. DIN 38414-19 : 1999-12English price group 06 Sales No. 010612.01DEUTSCHE NORM December 199938414-19Continued on pages 2 to 5. No part of this translation may be reproduced without the prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has
5、 the exclusive right of sale for German Standards (DIN-Normen).German standard methods for the examination of water, waste water and sludgeSludge and sediments (group S)Part 19: Determination of steam-volatile organic acids (S 19)Translation by DIN-Sprachendienst.In case of doubt, the German-languag
6、e original should be consulted as the authoritative text.1 ScopeThe intermediates produced by anaerobic degradation of organic substances include volatile organic acids.These acids can be used to monitor industrial digestion processes, especially the digestion of sewagesludge.The method specified in
7、 this standard serves to determine the steam-volatile organic acids in waste waterand liquid sludge in concentrations of 2 mmol to 20 mmol per litre. Higher concentrations may be determinedby diluting the sludge, and even solid sludge can be analysed if it can be made to flow by adding water.2 Norma
8、tive referencesThis standard incorporates, by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text, and the titles of the publications are listedbelow. For dated references, subsequent amendments to or revisions of
9、any of these publications apply tothis standard only when incorporated in it by amendment or revision. For undated references, the latestedition of the publication referred to applies.DIN 12348 Round bottom and flat bottom flasks fitted with 1 : 10 tapered socket for laboratoryuseDIN 12650-3 Piston-
10、operated dispensers for laboratory useDIN 12664-1 One-mark volumetric flasks with flanged rim, conical socket and conical joint, forlaboratory useDIN 12680-1 Graduated cylinders for laboratory useDIN 12691 Class AS fast delivery one-mark bulb pipettes, with a waiting time of 15 seconds, forlaborator
11、y useDIN 12700-3 Burettes fitted with offset burette stopcock with tail, for laboratory useDIN EN ISO 5667-13 Sampling of water Part 13: Guidance on sampling of sludges from sewage and watertreatment works (ISO 5667-13 : 1997)Page 2DIN 38414-19 : 1999-123 ConceptThe organic and steam-volatile acids
12、detected by this method are, when present in municipal waste watersludge, predominantly monocarboxylic acids containing up to six carbon atoms.4 PrincipleThe acids are steam-distilled from a solution acidified with phosphoric acid and, after any acid-forming gaseshave been removed from the distillat
13、e by refluxing, the latter is titrated with sodium hydroxide solution.5 InterferencesSince acid concentrations may change rapidly as a result of biochemical reactions, the samples shall beanalysed immediately after collection. If this is not possible, the determination may be carried out no later th
14、anthe following day, provided the sample is cooled rapidly and stored at 4 C.Vigorous foaming of the sample can be prevented by adding a defoaming agent.6 DesignationDesignation of the method of determining steam-volatile organic acids in sludges (S 19):Method DIN 38414 S 197 ApparatusThe following
15、equipment shall be used.a) Steam-destillation apparatus, as shown in figure 1, or any other suitable equipment.b) Reflux condenser (Allihn condenser), 30 cm long.c) Heating jacket, for flasks of nominal capacity 1000 ml.d) Dispenser, of nominal capacity 3 ml (e.g. DIN 12650-3 dispenser).e) Graduated
16、 cylinder, of nominal capacity 100 ml (e.g. DIN 12680 ME 100 graduated cylinder).f) Burette, of nominal capacity 25 ml (e.g. DIN 12700 SGA 25-005 burette).g) Piston-operated pipettes, of nominal capacities 50 ml, 100 ml and 250 ml.h) Volumetric flask, of nominal capacity 1000 ml (e.g. DIN 12664 MS A
17、 1000 volumetric flask).i) One-mark bulb pipette, of nominal capacity 20 ml (e.g. DIN 12691 VPAS 20 one-mark bulb pipette).8 ReagentsOnly analytical grade reagents shall be used and the water used shall be distilled water or water of equivalentpurity.The following reagents shall be used.8.1 0,1 moc1
18、08/c108 sodium hydroxide solution, NaOH.8.2 Phosphoric acid, H3PO4, of density 1,71 g/ml.8.3 1% (V/V) phenolphthalein solution, C20H14O4, in ethanol, C2H5OH.8.4 Standard acid solution, to be prepared by pouring water into a 1000 ml volumetric flask up to about 2 cmbelow the mark, adding 250 ml of ac
19、etic acid, CH3COOH, 100 ml of propionic acid, C2H5COOH, 100 ml of butyricacid, C3H7COOH, and 50 ml of valeric acid, C4H9COOH, below the liquid level using a piston-operated pipettefor each acid, making up to the mark with water and shaking.This solution contains about 7 mmol of organic acids per lit
20、re and will be stable for two weeks if refrigerated at4 C. Determine the acid concentration by titration with sodium hydroxide solution.Page 3DIN 38414-19 : 1999-129 Sampling and sample preparationEnsure that the samples collected are representative of the sludge under test. In the case of digesters
21、, it isrecommended that the samples be collected from the circulation line. To collect samples from containers,settling tanks, sludge thickeners or similar equipment in which strata or zones of different composition may beexpected, use suitable sludge siphons and combine the cores collected to form
22、composite samples. Furtherinformation on sampling is given in DIN EN ISO 5667-13.Wide mouth bottles made of polyolefins (e.g. polyethylene) with a screw cap are suitable as sample containers.Fill them to the brim and shake them immediately before removing the sample, proceeding as described inclause
23、 10.Sample components that settle rapidly (e.g. sand) need not be distributed homogeneously since they do notcontain any volatile organic acids.10 Procedure10.1 GeneralAfter diluting the sample if necessary, take 60 ml of the sludge using a graduated cylinder, transfer it to thedistillation vessel,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN38414191999GERMANSTANDARDMETHODSFORTHEEXAMINATIONOFWATERWASTEWATERANDSLUDGESLUDGEANDSEDIMENTSGROUPSPART19DETERMINATIONOFTHESTEAMVOLATILEORGANICPDF

链接地址:http://www.mydoc123.com/p-656512.html