CEPT T CS 54-02 E-1986 Maintenance of Signalling System R2 Use of Simplified Test Equipment (ETR 255 1996)《R2信令系统维护 简化测试设备的使用(ETR 255 1996)》.pdf
《CEPT T CS 54-02 E-1986 Maintenance of Signalling System R2 Use of Simplified Test Equipment (ETR 255 1996)《R2信令系统维护 简化测试设备的使用(ETR 255 1996)》.pdf》由会员分享,可在线阅读,更多相关《CEPT T CS 54-02 E-1986 Maintenance of Signalling System R2 Use of Simplified Test Equipment (ETR 255 1996)《R2信令系统维护 简化测试设备的使用(ETR 255 1996)》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、CEPT T/CS*54-02*E I23Zb414 0005346 8 69 TfCS54-02 Page E 1 Recommendation T/CS 54-02 (Stockholm 1977, revised in Cannes 1983) MAINTENANCE OF SIGNALLING SYSTEM R2; USE OF SIMPLIFIED TEST EQUIPMENT Recommendation proposed by Working Group T/WG 11 “Switching and Signalling” (CS) Revised text of the Rec
2、ommendation adopted by the “Telecommunication” Commission: “The European Conference of Postal and Telecommunications Administrations, considering - the extended use of Signalling System R2; that circuits operated with System R2 require rapid and simple testing of transmission and signalling in addit
3、ion to the use of the ATME No. 2 method specified by CCITT i. recommends that members of the CEPT should use with Signalling System R2, test equipment and procedures hereafter described, and provide a sufficient number of simplified responding equipment in their exchanges to avoid congestion on test
4、 calls. ” 1. GENERAL Generally speaking, the arrangements for au tomatic testing comprise outgoing test equipment connected at the outgoing end of the circuit and incoming test equipment (responding equipment) accessible at the incoming end. The procedures consist, in principle, of the setting-up of
5、 a call between the outgoing and the incoming test equipments. In addition to this functional signalling test, a check of the transmission on the circuit is achieved. 2. NUMBERING OF ACCESS TO SIMPLIFIED TEST EQUIPMENT 2.1. In international working, to Set-up a call to maintenance equipment via circ
6、uits operated with System R2, the following multifrequency signals must be sent: - 1-13 (replacing the language digit, in accordance with CCITT Recommendation 4.133 2); - two digits “XY” which will be associated with the type of test equipment and the procedure for testing - 1-15 (if requested by th
7、e incoming test equipment). Provision is made for repetition of signal 1-13 to avoid complications in the incoming R2 register in the country of destination. The second signal 1-13 is stored in the place where the first digit of the routing information is normally recorded. In this way, access to th
8、e test equipment requires no analysis, for routing purposes, of the signal which takes the place of the language digit. 1-13; to be employed. For access to the simplified test equipment XY = 90; 2.2. When calls are set-up to the test equipment, it is desirable to avoid repetition of the request for
9、the access code or for any other digit. This is because the calls may come from equipment which is not normally Interregister signalling on calls to simplified test equipment must be terminated as follows: - the address-complete signal A-6 alone or A-3 followed by B-6 is sent when the incoming test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTCS5402E1986MAINTENANCEOFSIGNALLINGSYSTEMR2USEOFSIMPLIFIEDTESTEQUIPMENTETR2551996R2 系统维护 简化 测试 设备

链接地址:http://www.mydoc123.com/p-593070.html