BS ISO 11534-2007 Iron ores - Determination of tin - Flame atomic absorption spectrometric method《铁矿石 锡含量的测定 火焰原子吸收光谱法》.pdf
《BS ISO 11534-2007 Iron ores - Determination of tin - Flame atomic absorption spectrometric method《铁矿石 锡含量的测定 火焰原子吸收光谱法》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 11534-2007 Iron ores - Determination of tin - Flame atomic absorption spectrometric method《铁矿石 锡含量的测定 火焰原子吸收光谱法》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58absorption spectrometric methodICS 73.060.10Iron ores Determination of tin Flame atomic BRITISH STA
2、NDARDBS ISO 11534:2006BS ISO 11534:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978-0-580-49905-0Amendments issued since publicationAmd. No. Date Commentscontract. Users are responsible for its correct appl
3、ication.Compliance with a British Standard cannot confer immunity from legal obligations.National forewordThis British Standard was published by BSI. It is the UK implementation of ISO 11534:2006. The UK participation in its preparation was entrusted to Technical Committee ISE/58, Iron ores.A list o
4、f organizations represented on ISE/58 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a Reference numberISO 11534:2006(E)INTERNATIONAL STANDARD ISO11534Second edition2006-11-15Iron ores Determination of tin Flame atomic absorpt
5、ion spectrometric methodMinerais de fer Dosage de ltain Mthode par spectromtrie dabsorption atomique dans la flamme BS ISO 11534:2006ii iiiContents Page Foreword iv 1 Scope . 1 2 Normative references . 1 3 Principle. 1 4 Reagents 2 5 Apparatus 3 6 Sampling and samples. 3 6.1 Laboratory sample 3 6.2
6、Preparation of predried test samples . 4 7 Procedure 4 7.1 Number of determinations . 4 7.2 Test portion . 4 7.3 Blank test and check test. 4 7.4 Determination 4 7.4.1 Decomposition of the test portion 4 7.4.2 Treatment of the test solution . 5 7.4.3 Adjustment of atomic absorption spectrometer . 5
7、7.4.4 Atomic absorption measurements 5 7.4.5 Preparation of calibration solutions . 6 8 Expression of results . 6 8.1 Calculation of mass fraction of tin 6 8.2 General treatment of results 6 8.2.1 Repeatability and permissible tolerances 6 8.2.2 Determination of the analytical result. 7 8.2.3 Betwee
8、n-laboratories precision 7 8.2.4 Check for trueness . 8 8.2.5 Calculation of final result. 8 8.3 Oxide factor . 9 9 Test report . 9 Annex A (normative) Flowsheet of the procedure for the acceptance of analytical values for test samples 10 Annex B (informative) Derivation of repeatability and permiss
9、ible tolerance equations . 11 Annex C (informative) Precision data obtained by international analytical trials . 12 BS ISO 11534:2006iv Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing
10、International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaiso
11、n with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of tec
12、hnical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is dra
13、wn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 11534 was prepared by Technical Committee ISO/TC 102, Iron ore and direct reduced iron, Subcommittee SC 2, Chemic
14、al analysis. This second edition cancels and replaces the first edition (ISO 11534:1998), which has been technically revised. It has been updated to alter the manner in which the precision data are presented. BS ISO 11534:20061Iron ores Determination of tin Flame atomic absorption spectrometric meth
15、od WARNING This International Standard may involve hazardous materials, operations and equipment. This International Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this International Standard to establish appropriate h
16、ealth and safety practices and determine the applicability of regulatory limitations prior to use. 1 Scope This International Standard specifies a flame atomic absorption spectrometric method for the determination of the mass fraction of tin in iron ores. This method is applicable to mass fractions
17、of tin between 0,001 % and 0,015 % in natural iron ores, iron ore concentrates and agglomerates, including sinter products. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For unda
18、ted references, the latest edition of the referenced document (including any amendments) applies. ISO 648: Laboratory glassware One-mark pipettes ISO 1042: Laboratory glassware One-mark volumetric flasks ISO 3082: Iron ores Sampling and sample preparation procedures ISO 3696: Water for analytical la
19、boratory use Specification and test methods ISO 7764: Iron ores Preparation of predried test samples for chemical analysis 3 Principle The test portion is treated with sulfuric acid and hydrofluoric acid in a platinum crucible. The silica is removed by heating and evaporation. The residue is fused i
20、n sodium carbonate/sodium tetraborate flux, and the cooled melt is dissolved in hydrochloric acid. Iron is reduced by ascorbic acid and potassium iodide, followed by extraction of tin with tri-n-octyl phosphine oxide (TOPO) in 4-methyl-2-pentanone (MIBK) solvent. The tin TOPO/MIBK extract is aspirat
21、ed into a dinitrogen oxide/acetylene flame and the absorbance of tin is measured at a 286,3 nm resonance line using a tin hollow-cathode lamp. The absorbance values obtained are compared with those obtained from calibration solutions. BS ISO 11534:20062 4 Reagents During the analysis, use only reage
22、nts of recognized analytical reagent grade, and only water that complies with grade 2 of ISO 3696. 4.1 Sodium carbonate (Na2CO3), anhydrous. 4.2 Sodium tetraborate (Na2B4O7), anhydrous. 4.3 Iron oxide (Fe2O3), of minimum purity 99,9 % (mass fraction) and mass fraction of tin 99,5 % (mass fraction) i
23、n a platinum crucible (with cover) with 5 ml of hydrochloric acid (4.4). After cooling, transfer the solution to a 500 ml one-mark volumetric flask, add 200 ml of hydrochloric acid (4.5), and dilute to volume with hydrochloric acid (4.5). 4.14 Tin standard solution, 40 g Sn/ml. Transfer 20 ml of tin
24、 standard solution (4.13) to a 100 ml one-mark volumetric flask, dilute to volume with hydrochloric acid (4.5) and mix. 4.15 Tin standard solution, 10 g Sn/ml. Transfer 5,0 ml of tin standard solution (4.13) to a 100 ml one-mark volumetric flask, dilute to volume with hydrochloric acid (4.5) and mix
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO115342007IRONORESDETERMINATIONOFTINFLAMEATOMICABSORPTIONSPECTROMETRICMETHOD 铁矿石 含量 测定 火焰 原子 吸收光谱

链接地址:http://www.mydoc123.com/p-583606.html