BS EN 61173-1995 Overvoltage protection for photovoltaic (PV) power generating systems - Guide《光电功率发生系统过压保护导则》.pdf
《BS EN 61173-1995 Overvoltage protection for photovoltaic (PV) power generating systems - Guide《光电功率发生系统过压保护导则》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61173-1995 Overvoltage protection for photovoltaic (PV) power generating systems - Guide《光电功率发生系统过压保护导则》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 61173:1995 IEC 1173:1992 Overvoltage protection for photovoltaic (PV) power generating systems Guide The European Standard EN 61173:1994 has the status of a British Standard UDC 621.383:621.316.9BSEN61173:1995 This British Standard, having been prepared under the directionof t
2、he Electrotechnical Sector Board (L/1), was publishedunder the authorityofthe Standards Boardand comes into effect on 15April1995 BSI 09-1999 The following BSI references relate to the work on this standard: Committee reference EPL/47 Special announcement in BSI News November 1993 ISBN 0 580 24007X
3、Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee EPL/47, Semiconductors, upon which the following bodies were represented: Federation of the Electronics Industry Ministry of Defence National Supervising Inspectorate The fo
4、llowing bodies were also represented in the drafting of the standard through subcommittees: Association of Manufacturers Allied to the Electrical and Electronics Industry (BEAMA Ltd.) British Telecommunications plc Society of British Aerospace Companies Limited Amendments issued since publication Am
5、d. No. Date CommentsBSEN61173:1995 BSI 09-1999 i Contents Page Committees responsible Inside front cover National foreword ii Text of EN61173 3BSEN61173:1995 ii BSI 09-1999 National foreword This British Standard has been prepared by Technical Committee EPL/47, and is the English language version of
6、 EN61173:1994, Overvoltage protection for photovoltaic (PV) power generating systems Guide, published by the European Committee for Standardization (CENELEC). It is identical with IEC1173:1992published by the International Electrotechnical Commission (IEC). A British Standard does not purport to inc
7、lude all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, page
8、s i and ii, theEN title page, pages2to8 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61173 September 1994 UD
9、C 621.383:621.316.9 Descriptors: Photovoltaic systems, power generating, overvoltage protection, sources of overvoltages, methods to reduce overvoltages English version Overvoltage protection for photovoltaic (PV) power generating systems Guide (IEC 1173:1992) Protection contre les surtensions des s
10、ystmes photovoltaques (PV) de production dnergie Guide (CEI 1173:1992) berspannungsschutz fr photovoltaische (PV) Stromerzeugungssysteme Leitfaden (IEC 1173:1992) This European Standard was approved by CENELEC on1994-03-08. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulation
11、s which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This Eur
12、opean Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are
13、 the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and UnitedKingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de
14、 Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1994 Copyright reserved to CENELEC members Ref. No. EN 61173:1994 EEN61173:1994 2 BSI 09-1999 Foreword The CENELEC questionnaire procedure, performed for finding
15、out whether or not the International Standard IEC1173:1992could be accepted without textual changes, has shown that no common modifications were necessary for the acceptance as a European Standard. The reference document was submitted to the CENELEC members for formal vote and was approved by CENELE
16、C as EN61173on8March1994. The following dates were fixed: Annexes designated “normative” are part of the body of the standard. In this standard, Annex ZA is normative. Contents Page Foreword 2 Introduction 3 1 Scope and object 3 2 Normative reference 3 3 Sources of overvoltages 3 3.1 External origin
17、 of overvoltages 3 3.2 Internal origin of overvoltages 3 4 Methods to reduce overvoltages 3 4.1 Equi-potentialization (bonding) 3 4.2 Grounding 3 4.3 Shielding 4 4.4 Stroke interception 4 4.5 Protective devices 4 4.6 Principle of operation 5 Annex ZA (normative) Other internationalpublications quote
18、d in thisstandardwith the references of therelevantEuropean publications 8 Figure 1 Illustration of PVPGS grounding 5 Figure 2 Example of three common methodsusedfor PVPGS grounding 6 Figure 3 Example of no grounding 7 latest date of publication of an identical national standard (dop) 1995-03-15 lat
19、est date of withdrawal of conflicting national standards (dow) 1995-03-15EN61173:1994 BSI 09-1999 3 Introduction Protection against the consequences of overvoltages may be needed to assure safety for personnel and equipment. Proper system design requires knowledge of all components overvoltage handl
20、ing capabilities. Overvoltages stress the insulation of different system components such as phase-to-phase or phase-structure insulations. Therefore, equipment should be selected and erected so as to comply with IEC364. The system should be designed, if applicable, to provide for protection of struc
21、tures against lightning. 1 Scope and object This International Standard gives guidance on the protection of overvoltage issues for both stand-alone and grid-connected photovoltaic power generating systems. It is intended to identify sources of overvoltage hazards (including lightning) to define the
22、types of protection such as grounding, shielding, stroke interception and protective devices. NOTEThe abbreviation PVPGS is used throughout this standard for photovoltaic power generating system(s). 2 Normative reference The following normative document contains provisions which, through reference i
23、n this text, constitute provisions of this International Standard. At the time of publication, the edition indicated was valid. All normative documents are subject to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying th
24、e most recent edition of the normative document indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. IEC 364, Electrical installations of buildings. 3 Sources of overvoltages Voltages greater than the maximum design voltage are considered the major h
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN611731995OVERVOLTAGEPROTECTIONFORPHOTOVOLTAICPVPOWERGENERATINGSYSTEMSGUIDE 光电 功率 发生 系统 保护 PDF

链接地址:http://www.mydoc123.com/p-577035.html