BS 7021-1989 Code of practice for thermal insulation of roofs externally by means of sprayed rigid polyurethane (PUR) or polyisocyanurate (PIR) foam《采用喷涂刚性聚氨基甲酸乙酯和聚异三聚氰脲酸酯泡沫对屋顶外部进行.pdf
《BS 7021-1989 Code of practice for thermal insulation of roofs externally by means of sprayed rigid polyurethane (PUR) or polyisocyanurate (PIR) foam《采用喷涂刚性聚氨基甲酸乙酯和聚异三聚氰脲酸酯泡沫对屋顶外部进行.pdf》由会员分享,可在线阅读,更多相关《BS 7021-1989 Code of practice for thermal insulation of roofs externally by means of sprayed rigid polyurethane (PUR) or polyisocyanurate (PIR) foam《采用喷涂刚性聚氨基甲酸乙酯和聚异三聚氰脲酸酯泡沫对屋顶外部进行.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 BSI BS*7021 O1 1b24bb9 0403154 430 BS 7021 : 1989 UDC 678.06 : 69.024.1 : 678.026.34 :678.664 : 691 : 001.4 : 614.8 : 620 .1 : 006.76(083.75) 1 0 British standards Instihition. No part of this publiestion may be pbmcopd . o( otherwise reproduced without the prior permission in Writing of BSI Britis
2、h Standard Code of practice for Thermal insulation of roofs externally by means of sprayed rigid polyurethane (PUR) or polyisocyanurate (PI R) foam Isolation thermique extrieure des toitures par plaques rigides de mousse de polyurthane (PUR) ou de polyisocyanurate (Pi RI- Code de bonne pratique Leit
3、faden zur Auenwrmedrnrnung von Dchern mit PUR-oder PIR-Hartschaurn British Standards Institution 4 6; -. BSI BS+702L O1 lb2Ybbq 0403155 377 BS 7021 : 1989 Foreword This British Standard has been prepared under the direction of the Plastics Standards Committee from a draft submitted by the British Ur
4、ethane Foam Contractors Association. It gives recommendations for the thermal insulation of roofs, externally, by the application of sprayed rigid polyurethane (PUR) or polyisocyanurate (PIR) foam, including criteria for determining the suitability of roofs for spraying. In addition guidance is incl
5、uded on the following: (a) determining the suitability of roof surfaces for direct spraying; (b) the preparation of roof surfaces prior to spraying; (c) the selection and application of primers and vapour barriers; (d) the selection and application of the external protective membrane applied after s
6、praying; (e) the fire performance of the modified roof as well as guidance on the health and safety aspects associated with the work. Attention is drawn to BS 5241 : Part 1 which specifies suitable PUR and PIR foam systems for use as recomm- ended in this code of practice and is published simultaneo
7、usly. Attention is also drawn to the fact that polyurethane or polyisocyanurate rigid foams are organic and hence combustible. It is important therefore that reference be made to clauses 10 and 11 dealing with health and safety aspects and fire performance respectively. Finally attention is drawn to
8、 the precautions indicated in 5.2.2 for work on asbestos sheet roofs. Compliance with a British Standard does not of itself confer immunity from legal obligations. BS 7021 : 1989 Contents Page Foreword Committees responsible Inside front cover Back cover Code of practice O Introduction 2 Definition
9、3 Composition and designation 4 Thermal performance of installed foam 5 Insulation of existing roofs 6 Insulation of new roofs 7 Primers and vapour check coatings 8 Foam application procedure 9 Protective mem branes 1 scope 10 Health and safety aspects 11 Fire performance Appendices A Method for det
10、ermining the on-site adhesive strength of sprayed rigid PUR or PIR foam B Method for the on-site determination of overall foam density Figures 1 2 3 4 5 Typical self-adhesive force applicator Characteristic sprayed foam surface texture: smooth Characteristic sprayed foam surface texture: orange peel
11、 Characteristic sprayed foam surface texture: pop corn Characteristic sprayed foam surface texture: tree bark 2 2 2 2 2 2 4 5 5 7 8 9 13 14 9 10 11 12 13 1 BSI BS17021 01 II624669 0403157 L4T = BS 7021 : 1989 Code of practice O Introduction Rigid PUR or PIR foam is applied by spraying on to the exte
12、rior surfaces of the roofs of buildings to reduce heat losses. After curing automatically, the foam is in the form of an auto-adhesive continuous covering of insulation of the correct thickness to confer on the roof a predetermined thermal transmittance value. The foam is applied to new and existing
13、 roofs of any configuration, although it is presently confined, in the UK, to the roofs of industrial, commercial and institutional buildings rather than domestic dwellings. Sprayed foam can be applied to almost all roofing materials although their surface preparation procedures often differ. This m
14、ethod of applying thermal insulation is particularly suitable for existing roofs. Providing the existing roof is sound the foam can be sprayed on to the old surface. If sections have deteriorated it is necessary to replace them before applying sprayed foam. The foam is always protected by a protecti
15、ve membrane which is sprayed on to the foam as soon as possible after the latter has cured. The function of the membrane is to protect the foam from solar radiation and from the ingress of water. These membranes are auto-adhesive continuous films which follow exactly the surface of the foam, They ar
16、e usually in the form of durable elastomeric materials which have a high weather resistance. Both the foam and the membrane are applied by means of purpose-built spraying machines. The foam components are delivered to the site as liquids. The foam components (usually two) are pumped under pressure b
17、y the machine in metered amounts and are intimately mixed in the spray gun when spraying. It is essential that spraying is carried out by trained operators. The reaction between the mixed liquids causes expansion of the inherent expanding agent to form the final foam. The membrane ingredients are us
18、ually premixed on site immediately prior to its application. 1 Scope This British Standard code of practice gives recommend- ations for the thermal insulation of roofs externally by spraying with rigid polyurethane (PUR) or polyisocyanurate (PIR) foam, and their subsequent protection by means of a p
19、rotective membrane applied in liquid form. NOTE. The titles of the publications referred to in this standard are listed on the inside back cover. 2 Definition For the purposes of this British Standard the following definition applies. 2.1 flat roof. A roof having an angle to the horizontal of less t
20、han 10 and otherwise complying with the requirements of BS 6229. 3 Composition and designation 3.1 General It is essential that the thermally insulating sprayed polyurethane (PUR) or polyisocyanurate (PI RI foam should comply with BS 5241 : Part 1. 3.2 Designation It is essential that designers spec
21、ify, in accordance with BS 5241 : Part 1, the correct type of foam for their particular application.?lpe 2 and type 4foams with their higher compressive strengths are for general use on roofs and flat roofs, whereas type 1 and type 3should be considered only for applications where the higher compres
22、sive strength characteristics are not needed, e.g. roof surfaces with a slope greater or equal to 45. 4 Thermal performance of installed foam The thermal conductivily value used for design p (2) edges of adjacent deck units should be fully supported or attached to prevent differential movement under
23、 load. 6.2 Surface preparation 6.2.1 General. Sprayed foam can be applied to any suitably prepared roof deck material, including timber, woodwool, concrete, profiled metal and corrugated sheeting or cement/ fibre composites. Preparation procedures pertinent to particular materials are given in 6.2.2
24、 to 6.2.5 inclusive. 6.2.2 Concrete and screeded roofs. Concrete and cement screeds can become waterlogged if not adequately protected. Vents are rarely effective in removing this water and provision should be made for drainage downwards. This can be achieved by the installation of appropriately spa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS70211989CODEOFPRACTICEFORTHERMALINSULATIONOFROOFSEXTERNALLYBYMEANSOFSPRAYEDRIGIDPOLYURETHANEPURORPOLYISOCYANURATEPIRFOAM

链接地址:http://www.mydoc123.com/p-546490.html