BS 3900-B15-1987 Methods of test for paints - Rapid method for estimation of lead in liquid paints《涂料试验方法 第B15集 液体涂料与干涂料膜化学检验 第15部分 液体涂料含铅量快速估算方法》.pdf
《BS 3900-B15-1987 Methods of test for paints - Rapid method for estimation of lead in liquid paints《涂料试验方法 第B15集 液体涂料与干涂料膜化学检验 第15部分 液体涂料含铅量快速估算方法》.pdf》由会员分享,可在线阅读,更多相关《BS 3900-B15-1987 Methods of test for paints - Rapid method for estimation of lead in liquid paints《涂料试验方法 第B15集 液体涂料与干涂料膜化学检验 第15部分 液体涂料含铅量快速估算方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 3900-B15: 1987 Methods of test for paints Part B15: Rapid method for estimation of lead in liquid paints It is recommended that this Part be read in conjunction with the general information in the Introduction to BS 3900, issued separately UDC 667.612:667.629.32 168.15BS 3900-B15
2、:1987 This British Standard, having been prepared under the directionof the Pigments, Paintsand Varnishes StandardsCommittee, was published under the authority ofthe Board of BSI and comesintoeffect on 27 February 1987 BSI 07-1999 The Committees responsible forthis British Standard are shown in BS 3
3、900: Introduction The following BSI references relate to the work on this standard: Committee reference PVC/10 Draft for comment 85/55930 DC ISBN 0 580 15610 9 Foreword This Part of BS 3900 has been prepared under the direction of the Pigments, Paints and Varnishes Standards Committee. The method of
4、 test described in this Part is a rapid procedure for the estimation of the amount of lead, within the range of0.01%(m/m) to0.1%(m/m), contained in liquid paint. The result obtained enables a decision to be taken as to whether the estimated lead content justifies an accurate determination of the con
5、tent by one of the methods described in PartB4 of this British Standard. Part B4 of BS3900 describes two methods for the determination, in the liquid product, of the total lead content of paints or similar materials using flame atomic absorption spectroscopy. The referee method for the determination
6、 of lead in the range of about 0.01%(m/m) to2%(m/m) uses a dry ashing procedure to obtain the test solution. An alternative method uses a wet oxidation procedure. It has been assumed in the drafting of this standard that it will be used and applied by those who are appropriately qualified and experi
7、enced. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document com
8、prises a front cover, an inside front cover, pages i and ii, pages 1 to 4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued s
9、ince publication Amd. No. Date of issue CommentsBS3900-B15:1987 BSI 07-1999 i Contents Page Foreword Inside front cover 1 Scope 1 2 Definitions 1 3 Principle 1 4 Apparatus and materials 1 5 Instrument calibration 1 6 Sampling 1 7 Procedure 1 8 Assessment of results 2 9 Test report 2 Figure 1 Positio
10、n of test strip in the flame 2 Figure 2 Typical recorder traces 3 Figure 3 Sample preparation 4 Table 1 Paint categorization 2 Publications referred to Inside back coverii blankBS3900-B15:1987 BSI 07-1999 1 1 Scope This Part of BS 3900 describes a method for the rapid examination of liquid paint to
11、ascertain the level of lead present in the range 0.01 % (m/m) to0.1% (m/m). The method is not applicable to those paints or similar products (e.g. fillers and putties) that do not allow a drop of the required diameter to be spotted onto a hardened filter paper. It is applicable principally to the ge
12、neral range of decorative and industrial paints. NOTEThe titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this Part of BS 3900, the definitions given in BS 2015 apply. 3 Principle A small drop of the paint sample is spotte
13、d onto a hardened filter paper and the lead present estimated by flame atomic absorption spectroscopy. 4 Apparatus and materials 4.1 Flame atomic absorption (A.A.) spectrophotometer, suitable for measurements at a wavelength of 283.3 nm and fitted with a burner fed with acetylene and air. 4.2 Lead s
14、pectral source comprising either a lead hollow-cathode lamp or lead discharge lamp. 4.3 Potentiometer chart recorder 4.4 Acetylene, commercial grade, in a steel cylinder. 4.5 Compressed air 4.6 Hardened filter paper NOTEWhatman No. 541 has been found to be satisfactory. 4.7 Glass rod, of sufficientl
15、y small diameter such that, when a drop of the paint is allowed to fall from it onto the hardened filter paper (4.6), it produces a spot of 4.5 0.5 mm diameter. 4.8 Pair of tongs 4.9 Reference paints, as follows: a) paint A containing a lead content, as Pb, of approximately 100 mg/kg; b) paint B con
16、taining a lead content, as Pb, of approximately 500 mg/kg; c) paint C containing a lead content, as Pb, of approximately 1000 mg/kg. The actual lead content of each of these paints shall be determined using the referee method described in BS 3900-B4. 5 Instrument calibration 5.1 Install the lead spe
17、ctral source (4.2) in the spectrophotometer (4.1) and optimize the conditions for the determination of lead. Adjust the instrument in accordance with the manufacturers instructions, and adjust the monochromator to the region of283.3 nm wavelength in order to obtain the maximum response. Lower the bu
18、rner of the spectrophotometer to its minimum height. Adjust the flow of the acetylene (4.4) and of the compressed air (4.5) according to the characteristics of the aspirator and burner, and ignite the flame. 5.2 As described in 7.2, prepare a test strip of hardened filter paper and apply a drop of p
19、aintC4.9 c). Using the pair of tongs (4.8), insert the paint spot on the test strip into the flame, as shown in Figure 1, and adjust the instruments conditions, so that the peak shown on the potentiometer chart recorder (4.3) is as close as possible to the maximum width of the chart recorder paper.
20、Repeat this procedure until three successive test strips give the same response to within 5 %. 5.3 Without further adjustment of the instruments conditions, carry out the procedure described in 7.2 to 7.4 for paint A 4.9 a), paint B 4.9 b) and paintC 4.9 c) to establish their peak heights. 5.4 Calcu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS3900B151987METHODSOFTESTFORPAINTSRAPIDMETHODFORESTIMATIONOFLEADINLIQUIDPAINTS 涂料 试验 方法 B15 液体 化学 检验

链接地址:http://www.mydoc123.com/p-543925.html