《ASTM F2826-2014 Standard Test Method for Evaluating the Sustained Air Performance and Exhaust Emission Efficiencies of Central Vacuum Cleaning Units《评估中心真空吸尘装置可持续空气性能和废气排放效率的标准试验方法.pdf》由会员分享,可在线阅读,更多相关《ASTM F2826-2014 Standard Test Method for Evaluating the Sustained Air Performance and Exhaust Emission Efficiencies of Central Vacuum Cleaning Units《评估中心真空吸尘装置可持续空气性能和废气排放效率的标准试验方法.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2826 14Standard Test Method forEvaluating the Sustained Air Performance and ExhaustEmission Efficiencies of Central Vacuum Cleaning Units1This standard is issued under the fixed designation F2826; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is a laboratory test for determining thesustained air perform
3、ance and Exhaust Emissions of a centralvacuum cleaner when tested under laboratory conditions.1.2 This test method is applicable to all central vacuumcleaners with or without any type of internal filter. This testmethod is intended to help indicate how performance may beaffected after multiple times
4、 of vacuuming over an extendedperiod of time.1.3 The inch-pound system of units is used in this standardexcept for weight measurements, which are measured in grams.The values stated in parentheses are given for information only.1.4 This standard does not purport to address all of thesafety concerns,
5、 if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1 Specification for ASTM Liquid-in-Glass Th
6、ermometersE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodF820 Test Method for Measuring Air Performance Charac-teristics of Central Vacuum Cleaning Systems2.2 ISO Standard:3ISO 5
7、011 Inlet Air Cleaning Equipment for Internal Com-bustion Engines and CompressorsPerformance Testing3. Terminology3.1 Definitions:3.1.1 exhaust emissionsmeasure of the efficiency of a unitto capture the loading media. Exhaust Emissions is (1 (theweight of the media exhausted into the exhaust emissio
8、ns bag,divided by the weight of the media introduced) 100).3.1.2 input power, W, nthe rate at which electrical energyis absorbed by a vacuum cleaner motor/fan system.3.1.3 model, nthe designation of a group of vacuumcleaner systems having the same mechanical and electricalconstruction.3.1.4 populati
9、on, nthe total of all units of a particularmodel vacuum cleaner system being tested.3.1.5 sample, na group of vacuum cleaner systems takenfrom a large collection of vacuum cleaner systems of oneparticular model, which serves to provide information that maybe used as a basis for making a decision con
10、cerning the largercollection.3.1.6 seal vacuuma water lift reading for a power unitwhen the inlet is entirely closed or sealed.3.1.7 standard air density, std, lb/ft3,natmospheric airdensity of 0.075 lb/ft3(1.2014 Kg/m3).3.1.7.1 DiscussionThis value of air density corresponds toatmospheric air at a
11、temperature of 68F (20C), 14.696 psi(101.325 kPa), and approximately 30 % relative humidity.3.1.8 suction, inches of water, nin a vacuum cleanersystem, the absolute difference between ambient and sub-atmospheric pressure.3.1.9 sustained air performance, nthe ability of a vacuumcleaner to maintain ai
12、r performance with a known quantity ofmedia aspirated into unit throughout a number of feedingcycles.3.1.10 test run, nthe definitive procedure that producesthe singular result.3.1.11 test station pressure, Bt, inches of mercury, nfor avacuum cleaner system, the absolute barometric pressure at thete
13、st location (elevation), and test time.3.1.11.1 DiscussionIt is not the equivalent mean sea levelvalue of barometric pressure typically reported by the airport1This test method is under the jurisdiction ofASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.22 on
14、 Air Perfor-mance.Current edition approved Jan. 15, 2014. Published January 2014. DOI: 10.1520/F2826-142For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards
15、 Document Summary page onthe ASTM website.3Available from International Organization for Standardization (ISO), 1, ch. dela Voie-Creuse, CP 56, CH-1211 Geneva 20, Switzerland, http:/www.iso.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United
16、 States1and weather bureaus. It is sometimes referred to as theuncorrected barometric pressure (that is, not corrected to themean sea level equivalent value).3.1.12 unit, na single vacuum cleaner system of the modelbeing tested.3.1.13 working vacuuma water lift reading value at anorifice causing a v
17、acuum equivalent to a standard cleaning toolapplied to the floor or rug.4. Significance and Use4.1 The test results allow comparison of sustained airperformance of central vacuum cleaners that employ variousmethods of separating the dirt from the air used to convey thedirt to the central power unit.
18、 The results will be expressed asa percentage of the original vacuum performance after loadinga prescribed weight of media.4.2 The test results will allow a comparison of emissions bymeasuring the media emitted during the test and expressing thisas an Exhaust Emissions.5. Apparatus5.1 Water Manomete
19、r, or equivalent instruments, to providemeasurements from 0 to 150 in. (3810 mm) of water inincrements of 0.1 in. (2.5 mm).5.2 Wattmeter, to provide measurements accurate to within61%.5.3 Voltmeter, to provide measurements accurate to within61%.5.4 Barometer, with an accuracy of 60.05 in. (1.27 mm)H
20、g, with scale divisions 0.02 in. (0.51 mm) or finer.5.5 Thermometer, solid stem thermometer having a rangefrom 18 to 89F (8 to 32C) with gradation of 0.2F (0.1C)increments and conforming to the requirements for thermom-eter 63F or 63C as prescribed in Specification E1.5.6 Voltage Regulator System, t
21、o control the input voltage tothe vacuum cleaner motor/fan system. The regulator systemshall be capable of maintaining the vacuum cleaners ratedvoltage 61 % and rated frequency 61 Hz having a wave formthat is essentially sinusoidal with 3 % maximum harmonicdistortion for the duration of the test.5.7
22、 Weighing Scale (for weighing media), accurate to 0.0035oz. (0.1 g) and having a weighing capacity of at least 1000 g.NOTE 1All available scales may not be suitable for this test method.Any scale considered for use in this test method shall be checked forsuitability in accordance with the requiremen
23、ts listed above.5.8 Stop Watch/Clock, with a second hand or other type ofequipment capable of establishing the specified rate of move-ment and total cycle time.5.9 Suction Fixture, used to feed test media and makevacuum readings. The suction fixture will be used for feedingthe media and measuring th
24、e vacuum by interchanging the feedtube and manometer tube. (See Fig. 1.)5.10 Emissions Collection Bag, minimum 6 gal capacity,15.2 mill disposable filter bag with a minimum quality of thefollowing features: 98.4 % dust retention of particle sizes downto and including 0.3 microns (as tested per ISO 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF28262014STANDARDTESTMETHODFOREVALUATINGTHESUSTAINEDAIRPERFORMANCEANDEXHAUSTEMISSIONEFFICIENCIESOFCENTRALVACUUMCLEANINGUNITS

链接地址:http://www.mydoc123.com/p-539552.html