ASTM F2561-2016 Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner《采用一件式主体和横向现场固.pdf
《ASTM F2561-2016 Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner《采用一件式主体和横向现场固.pdf》由会员分享,可在线阅读,更多相关《ASTM F2561-2016 Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner《采用一件式主体和横向现场固.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2561 11F2561 16Standard Practice forRehabilitation of a Sewer Service Lateral and Its Connectionto the Main Using a One Piece Main and Lateral Cured-in-Place Liner1,2This standard is issued under the fixed designation F2561; the number immediately following the designation indicates th
2、e year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This practice covers requirements and test
3、methods for the reconstruction of a sewer service lateral pipe having an innerdiameter of 3 to 12 in. (7.6 to 30.5 cm) and its connection to the main pipe having an inner diameter of 6 to 24 in. (15.2 to 61.0cm) without excavation. The lateral pipe is accessed remotely from the main pipe and from a
4、lateral cleanout. This will beaccomplished by the installation of a resin impregnated one-piece main and lateral cured in-place cured-in-place lining (MLCIPL)by means of air or water inflation and inversion. The MLCIPL is pressed against the host pipe by pressurizing a bladder and isheld in place un
5、til the thermoset resins have cured. When cured, the MLCIPL shall be a continuous, one piece, tight fitting,corrosion resistant lining extending over a predetermined length of the lateral pipe and the adjacent section of the main pipe,providing a verifiable non-leaking structural connection and seal
6、.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3 There is no similar or equivalent ISO Standard.1.4 This standard does not purp
7、ort to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. Particular attention is drawn to those safety r
8、egulations and requirements involving entering into andworking in confined spaces.2. Referenced Documents2.1 ASTM Standards:3D618 Practice for Conditioning Plastics for TestingD790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating MaterialsD1600 T
9、erminology for Abbreviated Terms Relating to PlasticsD3681 Test Method for Chemical Resistance of “Fiberglass” (GlassFiberReinforcedThermosetting-Resin) Pipe in a DeflectedConditionD5813 Specification for Cured-In-Place Thermosetting Resin Sewer Piping SystemsF412 Terminology Relating to Plastic Pip
10、ing SystemsF1216 Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube2.2 NASSCO Guidelines:4Recommended Specifications for Sewer Collection System Rehabilitation1 This practice is under the jurisdiction of ASTM Committee F17 on Plasti
11、c Piping Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless PlasticPipeline Technology.Current edition approved Dec. 1, 2011April 1, 2016. Published December 2011May 2016. Originally approved in 2006. Last previous edition approved in D256106. DOI:10.1520/F2561-11.2011 as
12、. DOI: 10.1520/F2561-16.2 The rehabilitation of a sewer service lateral and its connection to the main using a one-piece main and lateral cured-in-place liner is covered by patents (LMK Enterprises,Inc. 1779 Chessie Lane, Ottawa, IL 61350). Interested parties are invited to submit information regard
13、ing the identification of acceptable alternatives to this patented itemto the Committee on Standards, ASTM Headquarters, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. Your comments will receive careful consideration at ameeting of the responsible technical committee which may attend.3 For
14、 referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.4 NASSCO, Inc. 11521 Cronridge Drive, Suite J, Owings Mills, MD 21
15、117. www.nassco.orgThis document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that user
16、s consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
17、ocken, PA 19428-2959. United States13. Terminology3.1 DefinitionsUnless otherwise indicated, definitions are in accordance with Terminology F412, and abbreviations are inaccordance with Terminology D1600.3.2 Definitions of Terms Specific to This Standard:3.2.1 access pointan existing manhole at eith
18、er the upstream or downstream end of a sewer main or a cleanout located on thelateral pipe.3.2.2 bladdera transparent flexible plastic hose that when pressurized, causes the main sheet to be pressed against the mainpipe walls and the lateral tube to invert up into the sewer service lateral. The blad
19、der joined with the textile lining creates aliner/bladder assembly.3.2.3 inversionthe process of turning a resin-impregnated tube inside out by the use of air or water pressure.3.2.4 launchercombination of a rigid elongated tube and lay-flat hose apparatus where the main bladder is attached and them
20、ain sheet is wrapped around the exterior of the rigid portion. The lateral bladder and lateral liner istube are drawn inside the hose.The launcher is positioned within the main pipe; air pressure is introduced into the hose causing inflation of the main bladder/ sheetbladder/sheet and inversion of t
21、he lateral bladder tube.3.2.5 lifta portion of the MLCIPL that has cured in a position such that it has pulled away from the existinghost pipe wall.3.2.6 main and lateral cured in place cured-in-place lining (MLCIPL)a textile including plastic coating impregnated by athermosetting resin. This pipe i
22、s formed within a portion of the existing main pipe and the lateral pipe. Therefore, it takes the shapeof an existing TEE or WYE fitting and fits tightly to the existing pipes.3.2.7 resinpolyester, vinyl ester, epoxy or silicate resin systems being ambient, steam, or hot water cured.3.2.8 resin slug
23、excess resin at the upper most uppermost end of a lateral lining.3.2.9 sewer service laterala pipe servicing a building or a side service.3.2.10 sheeta flat textile sheet that is formed into a 16 inches in. (40.6 cm) long tube within the main pipe. The sheet isconnected to the lateral tube forming a
24、 one-piece TEE or WYE shaped fitting.3.2.11 transitionthe change in pipe diameter commonly found in lateral pipes.4. Significance and Use4.1 This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations who areinvolved in the rehabilitation of sewer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF25612016STANDARDPRACTICEFORREHABILITATIONOFASEWERSERVICELATERALANDITSCONNECTIONTOTHEMAINUSINGAONEPIECEMAINANDLATERALCUREDINPLACELINER

链接地址:http://www.mydoc123.com/p-538982.html