ASTM F1483-2012 Standard Specification for Oriented Poly(Vinyl Chloride) PVCO Pressure Pipe《定向聚氯乙烯 (PVCO) 压力管路的标准规范》.pdf
《ASTM F1483-2012 Standard Specification for Oriented Poly(Vinyl Chloride) PVCO Pressure Pipe《定向聚氯乙烯 (PVCO) 压力管路的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1483-2012 Standard Specification for Oriented Poly(Vinyl Chloride) PVCO Pressure Pipe《定向聚氯乙烯 (PVCO) 压力管路的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1483 12 An American National StandardStandard Specification forOriented Poly(Vinyl Chloride), PVCO, Pressure Pipe1This standard is issued under the fixed designation F1483; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers requirements for materials,dimensions, sustained pressure, accelerated regre
3、ssion testing,burst pressure, flattening, impact resistance, workmanship, andmethods of marking for oriented poly(vinyl chloride) (PVCO)pipe for pressure applications.1.2 The PVCO pipe shall be joined using elastomeric seals(gaskets). The joint shall meet the requirements of Specifica-tion D3139 and
4、 the elastomeric seal shall meet the require-ments of Specification F477. The PVCO shall not be joined bysolvent cementing.1.3 The values stated in inch-pound units are to be regardedas standard. The values in parentheses are given for informa-tion only.1.4 The following safety hazards caveat pertai
5、ns only to thetest method portion, Section 8 of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicab
6、ility of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD883 Terminology Relating to PlasticsD1598 Test Method for Time-to-Failure of Plastic PipeUnder Constant Internal PressureD1599 Test Method for Resistance to Sh
7、ort-Time HydraulicPressure of Plastic Pipe, Tubing, and FittingsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsD2122 Test Method for Determining Dimensions of Ther-mopla
8、stic Pipe and FittingsD2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe and Molded Fittings byAcetone ImmersionD2444 Test Method for Determination of the Impact Resis-tance of Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)D2837 Test Method for Obt
9、aining Hydrostatic Design Basisfor Thermoplastic Pipe Materials or Pressure Design Basisfor Thermoplastic Pipe ProductsD3139 Specification for Joints for Plastic Pressure PipesUsing Flexible Elastomeric SealsF412 Terminology Relating to Plastic Piping SystemsF477 Specification for Elastomeric Seals
10、(Gaskets) for Join-ing Plastic Pipe2.2 Other Standards:NSF Standard No. 14 for Plastic Piping Components andRelated Materials3ANSI/NSF Standard No. 61 for Drinking Water SystemComponentsHealth Effects3PPI-TR 3 Policies and Procedures for Developing Recom-mended Hydrostatic Design Stresses for Thermo
11、plasticPipe43. Terminology3.1 Definitions:3.1.1 GeneralDefinitions are in accordance with Termi-nologies D883 and F412 and abbreviations are in accordancewith Terminology D1600, unless otherwise indicated. Theabbreviation for poly(vinyl chloride) plastics is PVC.3.1.2 PVCO pipeabbreviation for orien
12、ted poly(vinylchloride) plastics. PVCO pipe is PVC pressure pipe whichattains a relatively high strength by reorienting the molecules.Conventionally extruded PVC pipe is expanded circumferen-tially (for example, 2-in. diameter is expanded to 4-in. diam-eter) through the application of pressure and t
13、emperature. The1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.25 on VinylBased Pipe.Current edition approved Sept. 1, 2012. Published November 2012. Originallyapproved in 1993. Last previous edition ap
14、proved in 2005 as F1483 05. DOI:10.1520/F1483-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available f
15、rom the National Sanitation Foundation, P.O. Box 1468, Ann Arbor,MI 48106.4Available from Plastics Pipe Institute, 1275 K St. N.W., Suite 400, Washington,DC 20005.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1expansion reorients the
16、 PVC molecular structure in the hoopdirection, thereby increasing the material strength.3.2 Definitions of Terms Specific to This Standard:3.2.1 expansion ratio (ER)the ratio of the finished PVCOpipe outside diameter to the outside diameter of the originalstarting stock.3.2.2 standard thermoplastic
17、pipe material designationcodethe molecularly oriented poly(vinyl chloride) materialsdesignation code shall consist of the abbreviation PVCO forthe type of plastics, followed by the ASTM type and grade inarabic numerals and the hydrostatic design stress in units of100 psi (0.69 MPa) with any decimal
18、figures dropped. TheASTM type and grade shall be that of the starting stockmaterial. The hydrostatic design stress shall be that of thefinished PVCO pipe.3.2.3 DISCUSSIONA complete material designationcode shall consist of four letters and four figures (for example;a PVCO pipe manufactured from 1245
19、4 (Type 1, Grade 1)material starting stock and having an HDB of 7100 psi (48.92MPa) HDS of 3550 psi) (24.46 MPa) will have a materialdesignation code of PVCO 1135).3.2.4 starting stockthe conventionally extruded PVC pipeof uniform wall thickness which will be expanded to a largerdiameter, molecularl
20、y oriented pipe.3.2.5 wall-thickness-ratio (WTR)the ratio of the finishedproduct wall thickness to the wall thickness of the startingstock.4. Classification4.1 GeneralThis specification covers PVCO made fromPVC plastic pipe, starting stock, having a hydrostatic designstress of 2000 psi (13.78 MPa) d
21、etermined in accordance withTest Method D2837. Finished PVCO pipe shall have a hydro-static design stress of 3550 psi (24.46 MPa) determined bytesting in accordance with Test Methods D1598, with dataevaluated in accordance with Test Methods D2837,asin6.3.2.5. Materials5.1 GeneralPoly(vinyl chloride)
22、 plastics used to makePVCO pipe meeting the requirements of this specification arecategorized by means of two criteria, namely (1) short-termstrength tests; and (2) long-term strength tests.5.1.1 Supplementary RequirementThis applies whenevera regulatory authority or user calls for the product to be
23、 used toconvey or to be in contact with potable water. Potable waterapplications products intended for contact with potable watershall be evaluated, tested, and certified for conformance withANSI/NSF Standard 61 or the health effects portion of NSFStandard No. 14 by an acceptable certifying organiza
24、tion whenrequired by the regulatory authority having jurisdiction.5.2 Basic MaterialsThis specification covers PVCO pipemade from PVC compounds having certain physical andchemical properties as described in Specification D1784.5.3 The PVC compound used for the starting stock of thispipe shall equal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF14832012STANDARDSPECIFICATIONFORORIENTEDPOLYVINYLCHLORIDEPVCOPRESSUREPIPE 定向 聚氯乙烯 PVCO 压力 管路 标准规范

链接地址:http://www.mydoc123.com/p-534973.html