ASTM E932-1989(2007) 752 Standard Practice for Describing and Measuring Performance of Dispersive Infrared Spectrometers《散射式红外光谱仪性能描述和测量的标准实施规程》.pdf
《ASTM E932-1989(2007) 752 Standard Practice for Describing and Measuring Performance of Dispersive Infrared Spectrometers《散射式红外光谱仪性能描述和测量的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E932-1989(2007) 752 Standard Practice for Describing and Measuring Performance of Dispersive Infrared Spectrometers《散射式红外光谱仪性能描述和测量的标准实施规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 932 89 (Reapproved 2007)Standard Practice forDescribing and Measuring Performance of DispersiveInfrared Spectrometers1This standard is issued under the fixed designation E 932; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the necessary information toqualify dispersive infrared instruments for spe
3、cific analyticalapplications, and especially for methods developed by ASTMInternational.1.2 This practice is not to be used as a rigorous test ofperformance of instrumentation.1.3 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsib
4、ility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 131 Terminology Relating to Molecular SpectroscopyE 168 Practices for General Techniques of In
5、frared Quanti-tative AnalysisE 387 Test Method for Estimating Stray Radiant PowerRatio of Dispersive Spectrophotometers by the OpaqueFilter MethodE 1252 Practice for General Techniques for Obtaining In-frared Spectra for Qualitative Analysis3. Terminology3.1 Definitions and SymbolsFor definitions of
6、 terms andsymbols, refer to Terminology E 131 and Compilation ofASTM Standard Definitions.34. Significance and Use4.1 This practice is intended for all infrared spectroscopistswho are using dispersive instruments for qualitative or quan-titative areas of analysis.4.2 The purpose of this practice is
7、to set forth performanceguidelines for testing instruments used in developing ananalytical method. These guidelines can be used to compare aninstrument in a specific application with the instrument(s) usedin developing the method.4.3 An infrared procedure must include a description of theinstrumenta
8、tion and of the performance needed to duplicate theprecision and accuracy of the method.5. Apparatus5.1 For the purposes of this practice, dispersive instrumentsinclude those employing prisms, gratings, or filters to separateinfrared radiation into its component wavelengths.5.2 For each new method,
9、describe the apparatus andinstrumentation both physically and mechanically, and also interms of performance as taught in this practice. That is, thedescription should give numerical values showing the fre-quency accuracy and the frequency and the photometricprecision. State the spectral slit width m
10、aximum or slit widthprogram if one is used.Where possible, state the maximum andminimum resolution if those data are a part of the instrumentdisplay. Show typical component spectra as produced by theinstrument to establish the needed resolution.5.3 If a computer program is used, describe the program
11、.Include the programming language and availability, or whetherthe program is proprietary to a manufacturer.6. Reference to this Practice in Standards6.1 Reference to this practice should be included in allASTM infrared methods. The reference should appear in thesection on apparatus where the particu
12、lar spectrometer isdescribed.7. Parameters in Spectroscopy7.1 Dispersive infrared spectrometers have a source ofquasi-monochromatic radiation together with a photometer formeasuring relative radiant power. Accurate spectrometry in-volves a large number of interrelated factors that determine thequali
13、ty of the radiant power passing through a sample and thesensitivity and linearity with which this radiant power can bemeasured. Assuming proper instrumentation and its use, theinstrumental factors responsible for inaccuracies in spectrom-etry are resolution, linearity (Practices E 168), stray radian
14、t1This practice is under the jurisdiction of ASTM Committee E13 on MolecularSpectroscopy and Separation Science and is the direct responsibility of Subcom-mittee E13.03 on Infrared and Near Infrared Spectroscopy.Current edition approved Dec. 1, 2007. Published December 2007. Originallyapproved in 19
15、89. Last previous edition approved in 2002 as E 932 - 89 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM websi
16、te.3Available from ASTM International Headquarters, 100 Barr Harbor Drive,West Conshohocken, PA 19428.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.power (Test Method E 387), and cell constants (PracticeE 1252). Rigorous measuremen
17、t of these factors is beyond thescope of this practice, and a more practical approach isdescribed for the accessible factors.8. Instrument Operation8.1 The analyst selects the proper instrumental operatingconditions in order to get satisfactory performance (1-3).4Because instrument design varies, th
18、e manufacturers recom-mendations are usually best. A record of operating conditionsshould be kept so that data can be duplicated by future users.8.2 In addition to operating conditions, the following shouldbe checked and recorded:8.2.1 Ambient temperature,8.2.2 Pen response time,8.2.3 Scanning speed
19、,NOTE 1In some instruments these functions are integrated in the scanmodes.8.2.4 Noise level, and8.2.5 Mechanical repeatability.8.3 Each of the above factors is important in the measure-ment of analytical wavenumber and photometric data. There isusually some lag between the recorded reading and the
20、correctreading. Proper selection of operating conditions and good,reproducible, sample handling techniques minimize these ef-fects or make the effects repeatable. For example:8.3.1 Variation in temperature of the monochromator orsample may cause changes in wavenumber precision andaccuracy.8.3.2 Scan
21、ning too fast will displace the apparent wavenum-ber towards the direction scanned and will decrease the peakabsorbance reading for each band.NOTE 2Some instruments provide for automatic monitoring andcorrection of this effect.8.4 Mechanical repeatability of the monochromator andrecording system as
22、well as positioning of chart paper areimportant in wavenumber measurement.8.4.1 Chart paper should be checked for uniformity of theprinted scale length as received and rechecked at time of use,particularly if the paper has been subjected to pronouncedhumidity changes. Instructions on obtaining prope
23、r mechanicalrepeatability may be given in the manufacturers literature.8.5 In the case of computerized dispersive instruments, anyspectrum printed from a computer file must be obtained asprescribed by the manufacturer and should be identical to theoriginal data.PRECISION AND ACCURACY9. Definitions9.
24、1 wavenumber precisiona measure of the capability of aspectrometer to return to the same spectral position as mea-sured by a well-defined absorption or emission band when theinstrument is reset or rescanned. The index used in this practiceis the standard deviation.9.2 wavenumber accuracythe deviatio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME93219892007752STANDARDPRACTICEFORDESCRIBINGANDMEASURINGPERFORMANCEOFDISPERSIVEINFRAREDSPECTROMETERS

链接地址:http://www.mydoc123.com/p-533798.html