ASTM E872-1982(2006) Standard Test Method for Volatile Matter in the Analysis of Particulate Wood Fuels《粒状木质燃料分析中挥发性物质的试验方法》.pdf
《ASTM E872-1982(2006) Standard Test Method for Volatile Matter in the Analysis of Particulate Wood Fuels《粒状木质燃料分析中挥发性物质的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E872-1982(2006) Standard Test Method for Volatile Matter in the Analysis of Particulate Wood Fuels《粒状木质燃料分析中挥发性物质的试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 872 82 (Reapproved 2006)Standard Test Method forVolatile Matter in the Analysis of Particulate Wood Fuels1This standard is issued under the fixed designation E 872; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method determines the percentage of gaseousproducts, exclusive of moisture vapor, in the analysis
3、sample ofparticulate wood fuel that is released under the specificconditions of the test. The particulate wood fuel may besanderdust, sawdust, pellets, green tree chips, hogged fuel, orother type particulate wood fuel having a maximum particlevolume of 16.39 cm3(1 in.3). Volatile matter, when determ
4、inedas herein described, may be used to indicate yields onprocesses to provide the basis for purchasing and selling or toestablish burning characteristics.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard do
5、es not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Sta
6、ndards:2D 346 Practice for Collection and Preparation of CokeSamples for Laboratory AnalysisD 2013 Practice for Preparing Coal Samples for AnalysisE 871 Method for Moisture Analysis of Particulate WoodFuels3. Summary of Test Method3.1 Volatile matter is determined by establishing the loss inweight r
7、esulting from heating wood under rigidly controlledconditions. The measured weight loss, corrected for moistureas determined in Method E 871, establishes the volatile mattercontent.4. Significance and Use4.1 The test procedures described in this test method can beused to determine the percentage of
8、gaseous products, exclu-sive of moisture vapor, of any particulate wood fuel meetingthe requirements specified in this test method.5. Apparatus5.1 Platinum Crucible, with closely fitting cover, or anickel-chromium crucible, with closely fitting cover, pre-firedto oxidize and stabilize the weight. Th
9、e crucible shall be of notless than 10 or more than 20-mL capacity, not less than 25 ormore than 35 mm in diameter, and not less than 30 or morethan 35 mm in height.5.2 Vertical Electric Tube FurnaceThe furnace may be ofthe form shown in Fig. 1. It shall be regulated to maintain atemperature of 950
10、6 20C in the crucible, as measured by athermocouple positioned in the furnace.6. Procedure6.1 Sampling:6.1.1 Place of SamplingTake sample where wood is beingloaded into or unloaded from means of transportation or whendischarged from storage bins or conveyors.NOTE 1Samples collected from the surface
11、of piles are, in general,unreliable because of the exposure to the environment. If necessary,collect nine increments from a foot or more below the surface at ninepoints covering the pile.6.1.2 Collection of Gross Sample:6.1.2.1 Collect increments regularly, systematically, andwith such frequency tha
12、t the entire quantity of wood sampledwill be represented proportionally in the gross sample.6.1.2.2 The quantity of the sample shall be large enough tobe representative but not less than 10 kg (22 lb).6.1.2.3 Place samples in an airtight container immediatelyafter collection. Maintain samples in the
13、 airtight containerwhenever possible to prevent gains or losses in moisture fromthe atmosphere.6.1.3 Sample reduction may be done by two methods, aconing and dividing process, or by using a riffle. Mixing,coning, and quartering are described and illustrated in PracticeD 346.1This test method is unde
14、r the jurisdiction of ASTM Committee E48 onBiotechnology and is the direct responsibility of Subcommittee E48.05 on BiomassConversion.Current edition approved Nov. 1, 2006. Published December 2006. Originallyapproved in 1982. Last previous edition approved in 1998 as E 872 82 (1998).2For referenced
15、ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME87219822006STANDARDTESTMETHODFORVOLATILEMATTERINTHEANALYSISOFPARTICULATEWOODFUELS 粒状 木质 燃料 分析 挥发性

链接地址:http://www.mydoc123.com/p-533698.html