ASTM E729-1996(2007) Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes Macroinvertebrates and Amphibians《用鱼、大型无脊椎动物和两栖动物进行剧毒毒性试验的标准指南》.pdf
《ASTM E729-1996(2007) Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes Macroinvertebrates and Amphibians《用鱼、大型无脊椎动物和两栖动物进行剧毒毒性试验的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E729-1996(2007) Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes Macroinvertebrates and Amphibians《用鱼、大型无脊椎动物和两栖动物进行剧毒毒性试验的标准指南》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 729 96 (Reapproved 2007)Standard Guide forConducting Acute Toxicity Tests on Test Materials withFishes, Macroinvertebrates, and Amphibians1This standard is issued under the fixed designation E 729; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Sco
3、pe1.1 This guide (1)2describes procedures for obtaininglaboratory data concerning the adverse effects (for example,lethality and immobility) of a test material added to dilutionwater, but not to food, on certain species of freshwater andsaltwater fishes, macroinvertebrates, and amphibians during 2to
4、 8-day exposures, depending on the species. These proce-dures will probably be useful for conducting acute toxicity testswith many other aquatic species, although modifications mightbe necessary.1.2 Other modifications of these procedures might be justi-fied by special needs or circumstances. Althou
5、gh using appro-priate procedures is more important than following prescribedprocedures, results of tests conducted using unusual proceduresare not likely to be comparable to results of many other tests.Comparison of results obtained using modified and unmodifiedversions of these procedures might pro
6、vide useful informationconcerning new concepts and procedures for conducting acutetests.1.3 This guide describes tests using three basic exposuretechniques: static, renewal, and flow-through. Selection of thetechnique to use in a specific situation will depend on the needsof the investigator and on
7、available resources. Tests using thestatic technique provide the most easily obtained measure ofacute toxicity, but conditions often change substantially duringstatic tests; therefore, static tests should not last longer than 96h, and test organisms should not be fed during such tests. Statictests s
8、hould probably not be conducted on materials that havea high oxygen demand, are highly volatile, are rapidly trans-formed biologically or chemically in aqueous solution, or areremoved from test solutions in substantial quantities by the testchambers or organisms during the test. Because the pH andco
9、ncentrations of dissolved oxygen and test material aremaintained at desired levels and degradation and metabolicproducts are removed, tests using renewal and flow-throughmethods are preferable and may last longer than 96 h; testorganisms may be fed during renewal and flow-through tests.Although rene
10、wal tests might be more cost-effective, flow-through tests are generally preferable.1.4 Acute tests may be performed to meet regulatory datarequirements or to obtain time-independent estimates of toxic-ity.1.4.1 If the objective is to obtain data to meet regulatoryrequirements, it may be necessary t
11、o limit the number ofobservation times based on stipulations of the regulatoryagency and cost considerations.1.4.2 If the objective of an acute toxicity test is to determinea time-independent (that is, incipient, threshold, or asymptotic)toxicity level, an appropriate number of observations must bet
12、aken over an exposure duration of sufficient length to establishthe shape of the toxicity curve or allow the direct or math-ematically estimated determination of a time-independent tox-icity value (1), or both.1.5 In the development of these procedures, an attempt wasmade to balance scientific and p
13、ractical considerations and toensure that the results will be sufficiently accurate and precisefor the applications for which they are commonly used. Amajor consideration was that the common uses of the results ofacute toxicity tests do not require or justify stricter require-ments than those set fo
14、rth herein. Although the tests may beimproved by using more organisms, longer acclimation times,and so forth, the requirements presented herein should usuallybe sufficient.1.6 Results of acute toxicity tests should usually be reportedin terms of an LC50 (median lethal concentration) or EC50(median e
15、ffective concentration) at the end of the test, but it isdesirable to provide information concerning the dependence ofadverse effects on both time and concentration. Thus, whenfeasible, flow-through and renewal tests should be conductedso that LC50s or EC50s can be reported from6htoanasymptotic (tim
16、e-independent, threshold, incipient) value, ifone exists. In some situations, it might only be necessary todetermine whether a specific concentration is acutely toxic tothe test species or whether the LC50 or EC50 is above or belowa specific concentration.1This guide is under the jurisdiction of AST
17、M Committee E47 on BiologicalEffects and Environmental Fate and is the direct responsibility of SubcommitteeE47.01 on Aquatic Assessment and Toxicology.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1980. Last previous edition approved in 2002 as E 729 96(2002).
18、2The boldface numbers in parentheses refer to the list of references at the end ofthis standard.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.1.7 This guide is arranged as follows:SectionReferenced Documents 2Terminology 3Summary o
19、f Guide 4Significance and Use 5Apparatus 6Facilities 6.1Special Requirements 6.2Construction Materials 6.3Metering System 6.4Test Chambers 6.5Cleaning 6.6Acceptability 6.7Hazards 7Dilution Water 8Requirements 8.1Source 8.2Treatment 8.3Characterization 8.4Test Material 9General 9.1Stock Solution 9.2T
20、est Concentration(s) 9.3Test Organisms 10Species 10.1Age 10.2Source 10.3Care and Handling 10.4Feeding 10.5Disease Treatment 10.6Holding 10.7Acclimation 10.8Quality 10.9Procedure 11Experimental Design 11.1Dissolved Oxygen 11.2Temperature 11.3Loading 11.4Beginning the Test 11.5Feeding 11.6Duration of
21、Test 11.7Biological Data 11.8Other Measurements 11.9Analytical Methodology 12Acceptability of Test 13Calculation of Results 14Report 151.8 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.9 This standard does not purport to ad
22、dress all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Section 7.2. Re
23、ferenced Documents2.1 ASTM Standards:3E 724 Guide for Conducting Static Acute Toxicity TestsStarting with Embryos of Four Species of SaltwaterBivalve MolluscsE 943 Terminology Relating to Biological Effects and En-vironmental FateE 1023 Guide for Assessing the Hazard of a Material toAquatic Organism
24、s and Their UsesE 1191 Guide for Conducting Life-Cycle Toxicity Testswith Saltwater MysidsE 1192 Guide for Conducting Acute Toxicity Tests onAqueous Ambient Samples and Effluents with Fishes,Macroinvertebrates, and AmphibiansE 1203 Practice for Using Brine Shrimp Nauplii as Food forTest Animals in A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME72919962007STANDARDGUIDEFORCONDUCTINGACUTETOXICITYTESTSONTESTMATERIALSWITHFISHESMACROINVERTEBRATESANDAMPHIBIANS

链接地址:http://www.mydoc123.com/p-533412.html