1、Designation: E 603 07An American National StandardStandard Guide forRoom Fire Experiments1This standard is issued under the fixed designation E 603; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis guide has been written to assist those planning to conduct full-scale compartment fireexperiments. There are many issues that should b
3、e resolved before such an experimental program isinitiated, and this guide is written with the objective of identifying some of these issues and presentingconsiderations that will affect each choice of procedure.This guide deals with any or all stages of fire growth in a compartment. Whether it is a
4、 single- ormulti-room experiment, observations can be made from ignition to flashover or beyond full-roominvolvement.One major reason for conducting research on room fires is to learn about the room fire buildupprocess so the results of standard fire test methods can be related to performance in ful
5、l-scale roomfires, allowing the further refinement of these test methods or development of new ones.Another reason concerns computer fire modeling. Full-scale tests can generate data needed formodeling. Comparisons of modeling with full-scale test results can serve to validate the model.The various
6、results among room fire tests reflect different experimental conditions. The intent of thisguide is to identify these conditions and discuss their effects so meaningful comparisons can be madeamong the room fire experiments conducted by various organizations.1. Scope1.1 This guide addresses means of
7、 conducting full-scale fireexperiments that evaluate the fire-test-response characteristicsof materials, products, or assemblies under actual fire condi-tions.1.2 It is intended as a guide for the design of the experimentand for the use and interpretation of its results. The guide isalso useful for
8、establishing laboratory conditions that simulatea given set of fire conditions to the greatest extent possible.1.3 This guide allows users to obtain fire-test-responsecharacteristics of materials, products, or assemblies, which areuseful data for describing or appraising their fire performanceunder
9、actual fire conditions.1.3.1 The results of experiments conducted in accordancewith this guide are also useful elements for making regulatorydecisions regarding fire safety requirements. The use forregulatory purposes of data obtained from experiments con-ducted using this guide requires that certai
10、n conditions andcriteria be specified by the regulating authority.1.4 The rationale for conducting room fire experiments inaccordance with this guide is shown in 1.5-1.81.5 Room fire experiments are a means of generating inputdata for computer fire models and for providing output datawith which to c
11、ompare modeling results.1.6 One of the major reasons for conducting room fireexperiments is as an experimental means of assessing thepotential fire hazard associated with the use of a material orproduct in a particular application. This should be borne inmind when designing nonstandard experiments.1
12、.7 A rationale for conducting room fire experiments is thecase when smaller-scale fire tests inadequately represent end-use applications.1.8 Afurther rationale for conducting room fire experimentsis to verify the results obtained with smaller scale tests, tounderstand the scaling parameters for such
13、 tests.1.9 Room fire tests can be placed into four main categories:reconstruction, simulation, research, and standardization.1.10 This standard is used to measure and describe theresponse of materials, products, or assemblies to heat andflame under controlled conditions, but does not by itselfincorp
14、orate all factors required for fire hazard or fire riskassessment of the materials, products, or assemblies underactual fire conditions1.11 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to es
15、tablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1This guide is under the jurisdiction ofASTM Committee E05 on Fire Standardsand is the direct responsibility of Subcommittee E05.13 on Large Scale Fire Tests.Current edition appro
16、ved July 1, 2007. Published August 2007. Originallyapproved in 1977. Last previous edition approved in 2006 as E 603 - 06e1.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2. Referenced Documents2.1 ASTM Standards:2D 4442 Test Method
17、s for Direct Moisture Content Measure-ment of Wood and Wood-Base MaterialsD 4444 Test Methods for Use and Calibration of Hand-HeldMoisture MetersD 5424 Test Method for Smoke Obscuration of InsulatingMaterials Contained in Electrical or Optical Fiber CablesWhen Burning in a Vertical Cable Tray Config
18、urationD 5537 Test Method for Heat Release, Flame Spread,Smoke Obscuration, and Mass Loss Testing of InsulatingMaterials Contained in Electrical or Optical Fiber CablesWhen Burning in a Vertical Cable Tray ConfigurationE 176 Terminology of Fire StandardsE 800 Guide for Measurement of Gases Present o
19、r Gener-ated During FiresE 906 Test Method for Heat and Visible Smoke ReleaseRates for Materials and Products Using a ThermopileMethodE 1321 Test Method for Determining Material Ignition andFlame Spread PropertiesE 1354 Test Method for Heat and Visible Smoke ReleaseRates for Materials and Products U
20、sing an Oxygen Con-sumption CalorimeterE 1355 Guide for Evaluating the Predictive Capability ofDeterministic Fire ModelsE 1537 Test Method for Fire Testing of Upholstered Furni-tureE 1590 Test Method for Fire Testing of MattressesE 1822 Test Method for Fire Testing of Stacked ChairsE 2067 Practice f
21、or Full-Scale Oxygen Consumption Calo-rimetry Fire TestsE 2257 Test Method for Room Fire Test of Wall and CeilingMaterials and Assemblies2.2 UL Standards:UL 1715 Room Corner Test3UL Subject 1040 Large Scale Open Corner Test32.3 ICBO Standards:Uniform Building Code Standard UBC 8-2 Standard TestMetho
22、d for Evaluating Room Fire Growth Contribution ofTextile Wallcoverings4Uniform Building Code Standard UBC 26-3 Room Fire TestStandard for Interior of Foam Plastic Systems42.4 FM Standard:FM 4880 Large Scale Open Building Corner Test52.5 ISO Standards:ISO 9705 Fire TestsFull Scale Room Fire Tests for
23、Surface Products6ISO 13943 Fire SafetyVocabulary6ISO 17025 General Requirements for the Competence ofTesting and Calibration Laboratories6GUM, Guide to the Expression of Uncertainty in Measure-ment62.6 NFPA Standards:NFPA 265 Methods of Fire Tests for Evaluating Room FireGrowth Contribution of Texti
24、le Wall Coverings7NFPA 286 Standard Method of Tests for Evaluating Contri-bution of Wall and Ceiling Interior Finish to Room FireGrowth7NFPA 555 Guide on Methods for Evaluating Potential forRoom Flashover72.7 Other Standard:DASMA 107 -98 (03) Room Fire Test Standard for GarageDoors Using Foam Plasti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME6032007STANDARDGUIDEFORROOMFIREEXPERIMENTS 房屋 防火 实验 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-533128.html