ASTM E2194-2009 Standard Practice for Multiangle Color Measurement of Metal Flake Pigmented Materials《金属片状加色剂材料的多角度颜色测量标准实施规程》.pdf
《ASTM E2194-2009 Standard Practice for Multiangle Color Measurement of Metal Flake Pigmented Materials《金属片状加色剂材料的多角度颜色测量标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2194-2009 Standard Practice for Multiangle Color Measurement of Metal Flake Pigmented Materials《金属片状加色剂材料的多角度颜色测量标准实施规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2194 09Standard Practice forMultiangle Color Measurement of Metal Flake PigmentedMaterials1This standard is issued under the fixed designation E 2194; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONSurfaces that exhibit different colors depending on the angles of illumination or sensing are said tobe “gonioapparent.” Co
3、lorimetric values of reflecting gonioapparent materials are derived fromspectrometric (narrow band) or colorimetric (broad band) measurements of reflectance factor, atvarious aspecular angles. When using spectral values, tristimulus values are computed using the CIEStandard Observer and the spectrum
4、 of the illuminant, as described in Practice E 308. This practice,E 2194, specifies the measurement of color observed at various aspecular angles.1. Scope1.1 This practice covers the instrumental requirements,standardization procedures, material standards, and parametersneeded to make precise instru
5、mental measurements of thecolors of gonioapparent materials. This practice is designed toencompass gonioapparent materials; such as, automotive coat-ings, paints, plastics, and inks.1.2 This practice addresses measurement of materials con-taining metal flake and pigments. The measurement of mate-ria
6、ls containing metal flakes requires three angles of measure-ment to characterize the colors of the specimen. The opticalcharacteristics of materials containing pearlescent and interfer-ence materials are not covered by this practice.NOTE 1Data taken by utilizing this practice are for gonio-appearanc
7、equality control purposes. This procedure may not necessarily supplyappropriate data for spatial-appearance or pigment identification.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to esta
8、blish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 284 Terminology of AppearanceE 308 Practice for Computing the Colors of Objects byUsing the CIE SystemE 805 Practice for Identification
9、of Instrumental Methods ofColor or Color-Difference Measurement of MaterialsE 1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple MeasurementsE 1708 Practice for Electronic Interchange of Color andAppearance DataE 2539 Practice for Multiangle Color Measurement
10、 of In-terference Pigments2.2 CIE Document:3Publication No. 15:2004 Colorimetry2.3 NIST (NBS) Publication:4LC-1017 Standards for Checking the Calibration of Spec-trophotometers2.4 ISO Publication:5ISO International Vocabulary of Basic and General Terms inMetrology (VIM)3. Terminology3.1 Terms and de
11、finitions in Terminology E 284 are appli-cable to this practice. See Section “Specialized Terminology onGonioapparent Phenomena.”3.2 DefinitionsUsually the term metallic refers to a metalmaterial. However, this standard employs the alternative defi-nition given in Terminology E 284 as:1This practice
12、 is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.12 on Gonioap-parent Color.Current edition approved June 1, 2009. Published June 2009. Originallyapproved in 2003. Last previous edition approved in 2003 as E 2194 - 03.2For r
13、eferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. National Committee of the CIE (International C
14、ommissionon Illumination), http:/www.cie.co.at/index_i.e.html.4Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.5ISO/IDE/OIML/BIPM, International Vocabulary of Basic and General Terms inMetrology, Internat
15、ional Organization for Standardization, Geneva Switzerland,1984.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.1 metallic, adjpertaining to the appearance of a go-nioapparent material containing metal flakes.3.3 Definitions of m
16、etrology terms in ISO InternationalVocabulary of Basic and General Terms in Metrology (VIM)are applicable to this practice.4. Summary of Practice4.1 This practice describes the procedures for the spectro-metric and colorimetric measurement of metal flake pigmentedmaterials. The results are reported
17、in terms of CIE tristimulusvalues and other color coordinate systems. Standardization ofthe instrument used to measure these materials is defined.Guidelines are given for the selection of specimens and ameasurement protocol given. Characterization of these mate-rials requires measurement at a near-s
18、pecular angle, a mid-specular angle and a far-specular angle. These preferredaspecular angles are 15, 45, and 110.5. Significance and Use5.1 Instrumental Measurement AnglesThis practice is de-signed to provide color data at specific measurement anglesthat can be utilized for quality control, color m
19、atching, andformulating in the characterization of metal flake pigmentedmaterials.5.2 MaterialsThis practice provides meaningful colorinformation for metal flake pigmented materials. This practicehas been tested and verified on paint and coatings, and thesame principles should apply to plastics cont
20、aining metallicflake. For materials containing pearlescent materials refer toPractice E 2539.5.3 UtilizationThis practice is appropriate for measure-ment and characterization of metal flake pigmented materials.These data may be used for quality control, incoming inspec-tion, or color correction purp
21、oses.5.4 Specimen RequirementsEven though a pair of speci-mens have the same color values at three angles, if there aredifferences in gloss, orange peel, texture, or flake orientation,they may not be a visual match.NOTE 2Information presented in this practice is based upon datataken on metallic mate
22、rials coatings. Applicability of this practice to othermaterials should be confirmed by the user.6. Apparatus6.1 InstrumentThis practice requires measurement atmultiple aspecular angles, usually accomplished by the use ofa multiangle spectrometer as specified in this practice tocharacterize metal fl
23、ake pigmented materials. Measurementwith a single geometry cannot characterize the gonioappear-ance of these materials.6.2 StandardizationA standardization plaque with as-signed spectral reflectance factor or tristimulus values traceableto a national standardizing laboratory for each specified as-pe
24、cular angle is required to standardize the instrument. Theinstrument manufacturer typically assigns the values to thisplaque.7. Geometric Conditions7.1 Conventional Color MeasurementIn general purposecolorimetry, the common geometry involves illuminating at45 and sensing at 0. This geometry is desig
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21942009STANDARDPRACTICEFORMULTIANGLECOLORMEASUREMENTOFMETALFLAKEPIGMENTEDMATERIALS 金属 片状 加色 材料

链接地址:http://www.mydoc123.com/p-530521.html