1、Designation: E2178 13Standard Test Method forAir Permeance of Building Materials1This standard is issued under the fixed designation E2178; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pare
2、ntheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is to determine the air permeance ofbuilding materials at various pressure differentials with theintent of determining an assigned a
3、ir permeance rate of thematerial at the reference pressure difference (P)of75Pa.1.2 The method is intended to assess flexible sheet or rigidpanel-type materials using a 1m1mspecimen size.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurements are included in t
4、hisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
5、Referenced Documents2.1 ASTM Standards:2E283 Test Method for Determining Rate of Air LeakageThrough Exterior Windows, Curtain Walls, and DoorsUnder Specified Pressure Differences Across the Speci-menE631 Terminology of Building ConstructionsE1677 Specification forAir Barrier (AB) Material or Systemf
6、or Low-Rise Framed Building Walls3. Terminology3.1 Definitions:3.1.1 For definitions of general terms related to buildingconstruction used in this test method, refer to TerminologyE631.3.2 Definitions of Terms Specific to This Standard:3.2.1 air permeancethe rate of air flow (L/s), per unit area(m2)
7、 and per unit static pressure differential (Pa).4. Significance and Use4.1 The purpose of this test is to measure the air permeanceof flexible sheet or rigid panel-type materials. The results ofthis test may be useful in determining suitability of thatmaterial as a component of an air retarder syste
8、m.4.2 This method does not address the installed air leakageperformance of building materials. The installed performanceof air retarder materials and air retarder systems in low-riseframed wall construction is addressed in Specification E1677.5. Sampling5.1 The number of specimens to be tested shall
9、 be suitableto establish an air leakage rate which is representative of theproduct. In no case shall less than five specimens be tested.NOTE 1Because of the variability in the manufacture of a product, thenumber of specimens to be tested may vary from product to product.Certain materials may have st
10、andard methods for sampling that shall beused to sample these materials.6. Test Apparatus6.1 A schematic of the air leakage test apparatus is pre-sented in Fig. 1.6.1.1 Airtight Test ChamberThe airtight test chambershall be at least 320 mm deep and capable of receivinga1mby 1 m test specimen, anchor
11、ed to the test chamber by meansof a compression frame and clamping devices. The testchamber and compression frame shall be stiff enough to limitdeflection within the operating flexibility of the gaskets used toseal the test specimen to the chamber. Two parallel ribbons ofself-adhesive gasket materia
12、l shall be applied at all sealingpoints of the apparatus/test specimen assembly. The gasketribbons shall be made of medium-density gasket material thatcan be fused or glued at joints. The test apparatus shall containan over-pressure control device and windows to verify thespecimen installation.6.1.2
13、 Flow Measuring DevicesThe flow measuring de-vices used to gage the air flow through the test specimen shallbe capable of measuring air flow rate from110-6m3/s (.001L/s) up to 1.88 10-2m3/s (18.8 L/s), with an accuracy of 63 % of the reading.6.1.3 Pressure Measuring DevicesThe static pressure dif-fe
14、rential across the test specimen shall be measured by pressure1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.41on Air Leakage and Ventilation Performance.Current edition approved Feb. 1, 2013. Publishe
15、d March 2013. Originallyapproved in 2001. Last previous edition approved in 2011 as E2178 11. DOI:10.1520/E2178-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to t
16、he standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1measuring devices with an accuracy of 6 0.5 % of the pressurereading. The laboratory barometric pressure shall be measuredwith a dev
17、ice capable of measuring barometric pressure within6 3 % of the reading.6.1.4 PipingThe piping connecting the flow measuringdevices and the vacuum blower shall be airtight and containflow control devices to regulate the static pressure across thetest specimen within 60.5 % of the pressure reading. T
18、he pipeconnection to the test chamber shall contain an air filter toprevent dust or particulate matter from affecting the flowmeasuring device reading. The piping downstream and up-stream of the flow measuring device shall be designed so theflow regime does not affect the devices accuracy. The pipin
19、gshall contain a temperature measuring device capable ofmeasuring air temperature within 60.5C to convert all flowrate measurement to STP.6.1.5 Vacuum BlowerThe blower used to create a vacuumin the test chamber shall be able to produce static pressuredifferential across the test specimen within 60.5
20、 % of thepressure reading.7. Specimen Preparation7.1 Conditioning for TestsUnless otherwise stated, allspecimens to be tested shall be conditioned for a minimumperiod of seven days at 21 6 1C and 40 6 5 % RH.7.2 Flexible Sheet MaterialsDue to lack of rigidity, flex-ible materials shall be tested ove
21、r a rigid support having an airpermeance much greater than the test specimen. An open grillor wire mesh/screen, fabricated with welded wire having aminimum of 25 mm 25-mm-square grid (or an alternativemeans that provides an equivalent degree of support and airpermeance) shall be used for this purpos
22、e. The wire meshportion of the support shall be welded or otherwise mechani-cally secured to a solid metal frame which shall be gasketedand compressed within the test frame.Adetailed description ofthe support grill, including the gage wire used, shall beincluded in the test report. Fig. 2 shows the
23、preparation for atypical flexible sheet material. The following procedure shallbe used to seal the perimeter of the specimen:FIG. 1 General Configuration of Test ApparatusE2178 1327.2.1 Apply a self-adhesive gasket ribbon over the frame ofthe wire mesh/screen around the entire perimeter of the testa
24、rea under investigation (1m1m);7.2.2 Apply a second self-adhesive gasket ribbon along theperimeter of the first ribbon in 7.2.1;7.2.3 All joints in the gasket ribbons shall be fused or glued;7.2.4 Cut the flexible sheet material specimen to 1100 mm 1100 mm;7.2.5 Upon removal of the protective paper
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21782013STANDARDTESTMETHODFORAIRPERMEANCEOFBUILDINGMATERIALS 建筑材料 透气性 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-530485.html