1、Designation: E 1910 04Standard Test Method forAgricultural pH Control Agents1This standard is issued under the fixed designation E 1910; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenth
2、eses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover determining if an adjuvantmeets the definitions of an acidifier, a basic blend, alkalinityagent, or buffer in Terminology E 15
3、19.1.2 The values stated in both inch-pound and SI units are tobe regarded separately as the standard. The values given inparentheses are provided for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of
4、 the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1126 Test Method for Hardness in WaterD 1193 Specification for Reagent WaterE 70 Test Method for pH of
5、 Aqueous Solutions With theGlass ElectrodeE 200 Practice for the Preparation, Standardization, andStorage of Standard and Reagent Solutions for ChemicalAnalysisE 1519 Terminology Relating to Agricultural Tank MixAdjuvants3. Summary of Test Method3.1 Test Method A measures the change in pH of a sampl
6、eon the addition of an acidifier or a basic blend. Test Method Bmeasures the buffer capacity of the adjuvant by titration.4. Significance and Use4.1 This test method is intended for products sold as tankmix adjuvants for use with agricultural products.4.2 Part A provides a determination of whether t
7、he pHmodification characteristics of the adjuvant tested meet thedefinition of an acidifier, alkalinity agent, or a basic blend inTerminology E 1519. Part B provides a measure of the buffercapacity of the adjuvant. This can be used to estimate theamount of a buffer that will be required to keep a sp
8、ray solutionat the desired pH.4.3 Other pH standards can be used (see Test Method E 70)as long as the pHs measured are not outside the range of thestandards used.4.4 If samples of the material to be used in a particularapplication are available, the first method can be used todetermine what adjuvant
9、 rate is required to obtain the desiredpH. The ability of an adjuvant to adjust the pH of a particularsystem will depend on the initial pH before addition.4.5 The second method can be used to determine the amountof an adjuvant required to change the pH of a quantity of spraysolution to the required
10、value (see Note 1).NOTE 1Many acidifiers and basic blends also are buffers, so the pHchange does not provide a useful measure of buffer capacity.5. Apparatus5.1 pH Meter, accurate to 0.01 unit.5.2 Combination Glass/Calomel Electrode, or separate glassand calomel electrodes or other suitable pH elect
11、rode system.5.3 Beakers, 250 mL.5.4 Magnetic Stirrer, 120 to 1200 rpm, or equivalent.5.5 Magnetic Stir Bar, 1 in. (2.5 cm) in length and38 in.(0.95 cm) in diameter.5.6 Burette, 50 mL, Class A.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicat
12、ed, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Societywhere such specifications are available.6.2 Purity of Water Unless otherwise indicated, referenceto water shall be understood to mean reagent water, Type I
13、V, asdefined by Specification D 1193 (see Note 2).NOTE 2Type IV grade reagent water may be prepared by distillation,ion exchange, reverse osmosis, electrodialysis, or a combination thereof.6.3 Synthetic Hard Water Stock, transfer 12.14 g of anhy-drous calcium chloride (CaCl2) and 5.55 g of magnesium
14、chloride hexahydrate (MgCl26H2O) to a 1000mL volumetric1These test methods are under the jurisdiction of ASTM Committee E35 onPesticides and Alternative Control Agents and are the direct responsibility ofSubcommittee E35.22 on Pesticide Formulations and Delivery Systems.Current edition approved Oct
15、1, 2004. Published October 2004. Originallyapproved in 1997. Last previous edition approved in 2000 as E 1910 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the
16、 standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.flask. Dissolve the reagents with approximately 750 mL ofwater and equilibrate to 20C. Dilute the solution to 1000 mLtotal volume wit
17、h water at 20C, stopper the flask and mix thesolution thoroughly. This mixture has a hardness equivalent to13680 ppm of calcium carbonate (CaCO3) and is based on acompositional ratio of 4:1 calcium to magnesium.6.4 Standard Hard Water, equivalent to a total hardness of342 ppm of calcium carbonate (C
18、aCO3). Transfer 25 mL ofsynthetic hard water stock by pipette to a 1000 mL volumetricflask and dilute to volume with water at 20C. Mix the solutionthoroughly (see Note 3).NOTE 3It is recommended that the total hardness be checked inaccordance with Test Method MT-73, CIPAC 1, EDTA titration.3Analtern
19、ate method is provided in Test Method D 1126, where the value isrepresented as CaCO3. A value within 6 5 % of the nominal hardnessvalue is acceptable.6.5 pH Reference Solution, pH 4.00.6.6 pH Reference Solution, pH 7.00.6.7 pH Reference Solution, pH 10.00.6.8 0.05 N Sodium Hydroxide, prepared accord
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME19102004TESTMETHODFORAGRICULTURALPHCONTROLAGENTS 农用 PH 控制 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-529774.html