《ASTM E1677-2005 Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls《低拱屋架建筑物墙壁用空气阻挡(AR)材料或系统标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1677-2005 Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls《低拱屋架建筑物墙壁用空气阻挡(AR)材料或系统标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1677 05Standard Specification foran Air Barrier (AB) Material or System for Low-Rise FramedBuilding Walls1This standard is issued under the fixed designation E 1677; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers minimum performances andspecification criteria for an air barrier (AB) material o
3、r systemfor framed walls of low-rise buildings. The intended users arepurchasers of the AB, specifiers of the AB and regulatorygroups. The provisions contained in this specification areintended to allow the user to design the wall performancecriteria and increase AB specifications to accommodate apa
4、rticular climate location, function, or design of the intendedbuilding. Air barrier performance and specification minimumswere selected with the service life of the building wall in mind.1.2 This specification focuses on ABs for opaque walls.Other areas of the exterior envelope, such as roofs, floor
5、s, andinterfaces between these areas are not included in this specifi-cation.1.3 This specification does not address air leakage into thewall cavity, that is, windwashing. No standardized test hasbeen developed that adequately identifies all of the influencingfactors and measures the impact of this
6、effect on the wallsthermal performance.1.4 The specifications in this standard are not intended to beutilized for energy load calculations and are not based on anexpected level of energy consumption.1.5 The values stated in inch-pound units are to be regardedas the standard. The values in parenthese
7、s are for informationonly and are closely approximated.1.6 The following safety hazards caveat pertains only to thetest method portion, Annex A1, of this specification. Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of th
8、e userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2C 755 Practice for Selection of Vapor Retarders for ThermalInsulationE96 Test Methods for Water Vapor Transmis
9、sion of Mate-rialsE 241 Guide for Limiting Water-Induced Damage to Build-ingsE 283 Test Method for Determining the Rate ofAir LeakageThrough Exterior Windows, Curtain Walls, and DoorsUnder Specified Pressure DifferencesAcross the SpecimenE 330 Test Method for Structural Performance of ExteriorWindow
10、s, Doors, Skylights, and Curtain Walls by UniformStatic Air Pressure DifferencesE 331 Test Method for Water Penetration of Exterior Win-dows, Skylights, Doors, Curtain Walls by Uniform StaticAir Pressure DifferenceE 1424 Test Method for Determining the Rate of Air Leak-age Through Exterior Windows,
11、Curtain Walls, and DoorsUnder Specified Pressure and Temperature DifferencesAcross the Specimen2.2 ASHRAE Standard:ASHRAE 62 Acceptable Indoor Air Quality32.3 American Society of Civil Engineers:4ASCE 7-88, 1990, Minimum Design Loads for Buildingsand Other Structure, Fig 1, Basic Wind Speed (mph)2.4
12、 Canadian Standard:5Air Barrier System For Walls of Low-Rise Buildings:Performance and Assessment1This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.41on Air Leakage and Ventilation.Current edition approv
13、ed Nov. 1, 2005. Published December 2005. Originallyapproved in 1995. Last previous edition approved in 2000 as E 1677 95 (2000)2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informatio
14、n, refer to the standards Document Summary page onthe ASTM website.3Available from American Society for Heating, Refrigerating, and Air Condi-tioning Engineers, Inc., 1791 Tullie Crete, N. E., Atlanta, GA 30329.4Available from The American Society of Civil Engineers (ASCE), 1801Alexander Bell Dr., R
15、eston, VA 20191.5Available from Canadian Standards Association (CSA), 178 Rexdale Blvd.,Toronto, ON Canada M9W1R3.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 Definitions:3.1.1 air exfiltrationair leakage out of
16、the building drivenby negative pressure.3.1.1.1 negative pressureair pressure on the outdoor sideof a building envelope lower than on the indoor side.3.1.2 air infiltrationair leakage into the building drivenby positive pressure.3.1.2.1 positive pressureair pressure on the outdoor sideof a building
17、envelope higher than on the indoor side.3.1.3 air leakagethe movement/flow of air through thebuilding envelope, which is driven by either positive (infiltra-tion) or negative (exfiltration) pressure differences, or both,across the envelope.3.1.3.1 DiscussionThese pressure differences are causedby wi
18、nd, mechanical systems, and temperature differences(stack effect).3.1.4 air leakage ratethe time rate of air flow across theair barrier. Expressed as cubic feet per minute per square footof AB surface at a stated pressure differential across the ABexpressed in inches of H2O. (Cubic metres per second
19、 persquare metre of AB surface at a pressure differential inPascals.)3.1.5 air barrier (AB)a material or system in buildingconstruction that is designed and installed to reduce air leakageeither into or through the opaque wall.3.1.6 opaque wallall exposed areas of a wall that encloseconditioned spac
20、e, except openings for windows, doors, andbuilding service systems.3.1.7 structural integrityfor the purpose of this specifica-tion, it is the ability of the AB to maintain air leakageperformance after exposure to elevated positive and negativepressure (see 5.1.2 for performance).3.1.8 ultra-violetr
21、adiation lying in the ultraviolet range;wavelengths shorter than visible light, but longer than X-rays.Ultraviolet light can effect the durability of some buildingmaterials.3.1.9 vapor retardera material or system that adequatelyimpedes the transmission of water vapor under specifiedconditions.3.1.9
22、.1 DiscussionFor practical purposes it is assumedthat the permeance of a vapor retarder will not exceed oneperm in inch-pound units (57.4 ng/(s m2 Pa), although atpresent this value may only be appropriate for residentialconstruction. For certain other types of construction, thepermeance must be low
23、er.3.1.10 water leakagepenetration of water onto the exte-rior plane of framing or cavity insulation under specifiedconditions of air pressure difference across theAB during a testperiod.3.1.11 water resistancethe capability of a material orsystem to retard water leakage.3.1.12 water vapor diffusion
24、the process by which watervapor spreads or moves through permeable materials caused bya difference in water vapor pressure.3.1.13 water vapor permeancethe time rate of watervapor transmission through unit area of flat material orconstruction induced by unit vapor pressure difference betweentwo speci
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME16772005STANDARDSPECIFICATIONFORANAIRRETARDERARMATERIALORSYSTEMFORLOWRISEFRAMEDBUILDINGWALLS 屋架

链接地址:http://www.mydoc123.com/p-529204.html