ASTM E200-2008 317 Standard Practice for Preparation Standardization and Storage of Standard and Reagent Solutions for Chemical Analysis《化学分析用试剂溶液的制备、标准化和贮存的标准实施规程》.pdf
《ASTM E200-2008 317 Standard Practice for Preparation Standardization and Storage of Standard and Reagent Solutions for Chemical Analysis《化学分析用试剂溶液的制备、标准化和贮存的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E200-2008 317 Standard Practice for Preparation Standardization and Storage of Standard and Reagent Solutions for Chemical Analysis《化学分析用试剂溶液的制备、标准化和贮存的标准实施规程》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 200 08Standard Practice forPreparation, Standardization, and Storage of Standard andReagent Solutions for Chemical Analysis1This standard is issued under the fixed designation E 200; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This prac
3、tice covers procedures for the preparation,standardization, and storage of the standard volumetric solu-tions and reagent testing solutions commonly used in chemicalanalysis.1.2 The information in this practice is arranged as follows:SectionsReferenced Documents 2Terminology 3Significance and Use 4A
4、pparatus 5Temperature effects 6Measurements 7Reagents 8Concentration of solutions 9Mixing of solutions 10Storage of solutions 11Preparation and standardization of solutions 12Precision and Bias 13Sodium hydroxide solution, 0.02 to 1.0 meq/mL (N) 14to19Hydrochloric acid, 0.02 to 1.0 meq/mL (N) 20to28
5、Sulfuric acid, 0.02 to 1.0 meq/mL (N) 29to33Hydrochloric acid, special 1 meq/mL (N) 34to38Sulfuric acid, special 1meq/mL (N) 39to43Silver nitrate solution, 0.1 meq/mL (N) 44to48Ammonium thiocyanate solution, 0.1 meq/mL (N) 49to53Iodine solution, 0.1 meq/mL (N) 54to58Sodium thiosulfate solution, 0.1
6、meq/mL (N) 59to63Potassium permanganate solution, 0.1 meq/mL (N) 64to68Potassium dichromate solution, 0.1 meq/mL(N) 69to73Methanolic sodium hydroxide solution, 0.5 meq/mL (N) 74to79Ceric sulfate solution, 0.1 meq/mL (N) 80to84Acetous perchloric acid, 0.1 meq/mL (N) 85to89Disodium ethylenediaminetetr
7、aacetate solution, 0.05 mol/L(M)90 to 94Standard ion solutions 95Nonstandardized reagent solutions and indicator solutions 961.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of t
8、hesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific warningstatements are given throughout this practice.2. Ref
9、erenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterE50 Practices for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial a
10、nd Spe-cialty ChemicalsE 203 Test Method forWater UsingVolumetric Karl FischerTitrationE 694 Specification for Laboratory Glass Volumetric Appa-ratus2.2 Other Document:Reagent Chemicals, American Chemical Society Specifi-cations (ACS)33. Terminology3.1 Definition:3.1.1 standard volumetric solutiona
11、solution of accuratelydetermined concentration used in the quantitative analysis ofchemicals and other products. The concentration of suchsolutions is usually expressed in terms of meq/mL (N) normal-ity or mol/L (M) molarity.4. Significance and Use4.1 The accuracy of many analytical measurements is
12、de-pendent upon the manner in which the standard solutions areprepared and stored, and the accuracy with which they arestandardized. Combining the methods recommended for thepreparation and handling of such solutions into one practice1This practice is under the jurisdiction of ASTM Committee E15 on
13、Industrialand Specialty Chemicals and is the direct responsibility of Subcommittee E15.01 onGeneral Standards.Current edition approved Dec. 15, 2008. Published January 2009. Originallyapproved in 1962 as as E 200 62T. Last previous edition approved in 2001 asE 200 97(2001)1.2For referenced ASTM stan
14、dards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Chemical Society, 1155 16th St., N.W., Washington,DC 20036.1*
15、A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.eliminates the necessity for covering such details in all of themethods wherein the solutions are used.5. Apparatus5.1 Vo
16、lumetric GlasswareThe use of ordinary volumetricglassware will meet the accuracy requirements of many testmethods.NOTE 1For dependable accuracy, volumetric glassware meeting therequirements for Class A items given in Specification E 694 should beused.While for normal work apparatus meeting these spe
17、cifications can beused without calibration corrections, it is preferable that such calibrationcorrections be used in standardizing volumetric solutions. Such correc-tions may be of significance when the volumetric ware is frequently usedwith alkali solutions, for the corrosive effect of the alkali u
18、pon the glassmay result in changes in the apparent volume. It is recommended,therefore, that volumetric glassware, particularly burets and transferpipets, be recalibrated at 3-month intervals if it is frequently used tomeasure alkali solution volumes.5.2 BuretA 50-mL buret, or alternatively, a 100-m
19、L buretwith a 50-mL bulb at the top and a 50-mL stem below, may beused. For use with alkali solutions, burets equipped withTFE-fluorocarbon stopcock plugs are preferable.6. Temperature Effects6.1 Volumetric solutions are often used at temperaturesdiffering from those at which the standardization was
20、 carriedout. Significant errors may be introduced when the solutionsare used at these other temperatures. Values for the change ofnormality with temperature (D N/C) have been established forthe volumetric solutions described herein, and are listed inTable 1. When warranted by the desired accuracy of
21、 the work,normalities of standard solutions may be corrected to thetemperature at which they are used as follows:Nt25 Nt11 t12 t2!F! (1)where:Nt1= meq/mL (N) of solution when standardized,Nt2= meq/mL (N) of solution when used,t1= temperature of solution during standardization, Ct2= temperature of so
22、lution during use, C, andF = factor to correct for thermal expansion of the solution(DN/C values from Table 1).6.2 From the above equation it will be seen that thecorrection is to be added to the meq/mL (N) of the solutionwhen standardized if the temperature of use is lower than thetemperature of st
23、andardization while the correction is to besubtracted if the temperature of use is higher than the tempera-ture of standardization.7. Measurements7.1 WeighingsWhen it is directed that a chemical shouldbe “accurately weighed,” the weighing is to be performed in amanner so as to limit the error to 0.1
24、 % or less. Where aspecific weight of substance is designated in a procedure, it isintended, unless otherwise specified in the individual proce-dure, that a quantity within 65 % of the designated weight beused, and that this quantity be “accurately weighed” as justdefined.NOTE 2In weighing primary s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME2002008317STANDARDPRACTICEFORPREPARATIONSTANDARDIZATIONANDSTORAGEOFSTANDARDANDREAGENTSOLUTIONSFORCHEMICALANALYSIS

链接地址:http://www.mydoc123.com/p-527113.html