ASTM E124-1994(2010) 3125 Standard Specification for Weighing and Drying Apparatus for Microchemical Analysis《微量化学分析用称量和干燥仪器的标准规范》.pdf
《ASTM E124-1994(2010) 3125 Standard Specification for Weighing and Drying Apparatus for Microchemical Analysis《微量化学分析用称量和干燥仪器的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E124-1994(2010) 3125 Standard Specification for Weighing and Drying Apparatus for Microchemical Analysis《微量化学分析用称量和干燥仪器的标准规范》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E124 94 (Reapproved 2010)Standard Specification forWeighing and Drying Apparatus for Microchemical Analysis1This standard is issued under the fixed designation E124; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers apparatus used for weighingand drying operations in microchemical laboratory practic
3、e.1.2 The values stated in inch-pound units are to be regardedas the standard. The metric equivalents may be approximate.NOTE 1This specification was originally developed by the Committeeon MicrochemicalApparatus, Division ofAnalytical Chemistry,AmericanChemical Society.22. Referenced Documents2.1 A
4、STM Standards:3E671 Specification for Maximum Permissible Thermal Re-sidual Stress in Annealed Glass Laboratory ApparatusE920 Specification for Commercially Packaged LaboratoryApparatusE921 Specification for Export Packaged Laboratory Appa-ratusE1133 Practice for Performance Testing of Packaged Labo
5、-ratory Apparatus for United States Government Procure-mentsE1157 Specification for Sampling and Testing of ReusableLaboratory Glassware3. Combustion Boats3.1 Combustion boats of three sizes shall conform to therequirements in Table 1 and Fig. 1, Fig. 2, and Fig. 3. Theseboats shall be made of plati
6、num-rhodium alloy containing3.5 % rhodium.4. Weighing Bottles4.1 Weighing bottles of seven capacities shall conform tothe requirements in Table 2 and Figs. 4-9, inclusive.5. Weighing Cup5.1 The weighing cup shall conform to the requirementsshown in Fig. 11, and shall be made of platinum-rhodium allo
7、ycontaining 3.5 % rhodium. The cup is designed to be used as asample container to fit into the weighing bottle shown in Fig.5, and is useful for weighing hygroscopic materials.6. Weighing Tubes6.1 Weighing tubes of three types shall conform to therequirements shown in Fig. 12, Fig. 13, and Fig. 14.
8、Thesetubes should preferably be made of soda-lime glass.7. Spatulas7.1 Spatulas of four types, and preferably made of stainlesssteel, shall conform to the following requirements:7.1.1 TypeA(Fig. 15)This spatula is generally useful. Thetop can be used for crushing crystals and the bent blade forscrap
9、ing containers.7.1.2 Type B (Fig. 16)This spatula has a flat bent portionat one end and a V-shaped scoop at the other end. It isparticularly useful for weighing samples.7.1.3 TypeC(Fig. 17)This spatula is suitable for thelarger samples commonly encountered in semimicro and pre-parative work. It has
10、a U-shaped scoop at one end and aV-shaped scoop at the other end. The spatula can be used to addshot or beads to tare flasks and for measuring and introducingsolid reagent into combustion tubes.7.1.4 TypeD(Fig. 18)This spatula is useful in manymicrochemical applications.8. Forceps8.1 Forceps of two
11、types, made of nickel-plated steel, shallconform to the following requirements:8.1.1 Forceps with Platinum5 % Ruthenium Tips (Fig.19) The pin serves as a stop to prevent the forceps from beingdepressed to such an extent that the tips can open, allowing the1This specification is under the jurisdictio
12、n of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved July 1, 2010. Published July 2010. Originally approvedin 1956. Last previous edition approved in 2005 as E124 94 (2005). DOI:10.1520/E0124-94R10.2See the “1949
13、Report on Recommended Specifications for MicrochemicalApparatus, Carbon-Hydrogen, Dumas Nitrogen, Sulfur and Halogen,” AnalyticalChemistry, Vol 21, December 1949, p. 1555; and the “1953 Report on Recom-mended Specifications for Microchemical Apparatus, Weighing and Drying,”Analytical Chemistry, Vol
14、26, July 1954, p. 1186.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Bar
15、r Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.held object to drop. When pressed together, the tips makecontact for a distance of14 to12 in. (6.4 to 12.7 mm).NOTE 2Depending upon the intended use, other materials may besubstituted for the platinum alloy. Thec constructi
16、on and over-all dimen-sions should be identical with those shown in Fig. 19.8.1.2 Forceps with Conical Tapered Holders (Fig. 20)These forceps shall be made of spring steel. They are useful forhandling weighing tubes, absorption tubes, filter tubes, etc.9. Tare Flasks9.1 Tare flasks of three types, m
17、ade of soda-lime glass, shallconform to the requirements shown in Fig. 21, Fig. 22, and Fig.23. The serial numbers shall be etched on the flasks.10. Metal Cooling Block10.1 The metal cooling block shall conform to the require-ments shown in Fig. 24, and shall be made of a metal or alloywith a high h
18、eat conductivity. The surface should be highlyresistant to abrasion and corrosion.11. Metal Crucible Container with Glass Cover11.1 This assembly shall conform to the requirementsshown in Fig. 25, and shall consist of an aluminum body anda borosilicate-glass cover. It may be used in combination with
19、the metal cooling block, Fig. 24. The combination, commonlytermed a “microdesiccator,” serves primarily as a container forcooling, storage, and safe transportation of microweighingequipment.12. Micro Glass Desiccator with Metal Insert12.1 The micro glass desiccator shall conform to the re-quirements
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME124199420103125STANDARDSPECIFICATIONFORWEIGHINGANDDRYINGAPPARATUSFORMICROCHEMICALANALYSIS 微量 化学分析

链接地址:http://www.mydoc123.com/p-526906.html