《ASTM D7504-2015 0379 Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number《采用气相色谱法和有效碳数测定单环芳烃中微量杂质的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7504-2015 0379 Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number《采用气相色谱法和有效碳数测定单环芳烃中微量杂质的标准试验方法》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7504 15Standard Test Method forTrace Impurities in Monocyclic Aromatic Hydrocarbons byGas Chromatography and Effective Carbon Number1This standard is issued under the fixed designation D7504; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of totalnonaromatic hydrocarbons and mon
3、ocyclic aromatic hydrocar-bons in benzene, toluene, ethylbenzene, p-xylene, o-xylene,styrene and mixed xylenes by gas chromatography. The purityof benzene, toluene, ethylbenzene, p-xylene, o-xylene, styreneand mixed xylenes is also calculated. Similar test methods,using the internal standard calibra
4、tion technique and theexternal standard calibration technique, are Test MethodsD2360, D3797, D4492, D5060, D5135, D5917, and D6563respectively.1.2 A small amount of benzene in toluene, ethylbenzene,p-xylene, o-xylene, styrene and mixed xylenes may not bedistinguished from the non-aromatics and the c
5、oncentrationsare determined as a composite (see 6.1).1.3 The limit of detection (LOD) is 0.0002 wt % and limitof quantitation (LOQ) is 0.0006 wt % for impurities in toluene,mixed xylenes, p-xylene, o-xylene, ethylbenzene, benzene, andstyrene.1.4 In determining the conformance of the test results usi
6、ngthis method to applicable specifications, results shall berounded off in accordance with the rounding-off method ofPractice E29.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address
7、all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D841 Specification
8、 for Nitration Grade TolueneD1555M Test Method for Calculation of Volume and Weightof Industrial Aromatic Hydrocarbons and CyclohexaneMetricD2360 Test Method for Trace Impurities in MonocyclicAromatic Hydrocarbons by Gas ChromatographyD3437 Practice for Sampling and Handling Liquid CyclicProductsD37
9、97 Test Method for Analysis of o-Xylene by Gas Chro-matography (Withdrawn 2014)3D4492 Test Method for Analysis of Benzene by Gas Chro-matographyD4790 Terminology of Aromatic Hydrocarbons and RelatedChemicalsD5060 Test Method for Determining Impurities in High-Purity Ethylbenzene by Gas Chromatograph
10、yD5135 Test Method for Analysis of Styrene by CapillaryGas ChromatographyD5136 Specification for High Purity p-XyleneD5211 Specification for Xylenes for p-Xylene FeedstockD5917 Test Method for Trace Impurities in MonocyclicAromatic Hydrocarbons by Gas Chromatography andExternal CalibrationD6229 Test
11、 Method for Trace Benzene in HydrocarbonSolvents by Capillary Gas ChromatographyD6563 Test Method for Benzene, Toluene, Xylene (BTX)Concentrates Analysis by Gas ChromatographyD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice
12、for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE177 Practice for Use of the Terms Precision and Bias inASTM Test Methods1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibili
13、ty ofSubcommittee D16.01 on Benzene, Toluene, Xylenes, Cyclohexane and TheirDerivatives.Current edition approved July 1, 2015. Published July 2015. Originally approvedin 2009. Last previous edition approved in 2012 as D7504 12. DOI: 10.1520/D7504-15.2For referenced ASTM standards, visit the ASTM web
14、site, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.*A Summary of Changes secti
15、on appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E260 Practice for Packed Column Gas ChromatographyE355 Practice for Gas Chromatography Terms and Relation-shipsE691 Practice for Conducting an Inter
16、laboratory Study toDetermine the Precision of a Test MethodE1510 Practice for Installing Fused Silica Open TubularCapillary Columns in Gas Chromatographs2.2 Other Document:OSHA Regulations, 29 CFR paragraphs 1910.1000 and1910.120043. Terminology3.1 See Terminology D4790 for definitions of terms used
17、 inthis test method.4. Summary of Test Method4.1 The specimen to be analyzed is injected into a gaschromatograph equipped with a flame ionization detector (FID)and a capillary column. The peak area of each component ismeasured and adjusted using effective carbon number (ECN)5response factors. The co
18、ncentration of each component iscalculated based on its relative percentages of total adjustedpeak area and normalized to 100.0000 %.5. Significance and Use5.1 Determining the type and amount of hydrocarbon im-purities remaining from the manufacture of toluene, mixedxylenes, p-xylene, o-xylene, ethy
19、lbenzene, benzene, and sty-rene used as chemical intermediates and solvents is oftenrequired. This test method is suitable for setting specificationsand for use as an internal quality control tool where theseproducts are produced or are used. Typical impurities are:alkanes containing 1 to 10 carbons
20、 atoms, benzene, toluene,ethylbenzene (EB), xylenes, and aromatic hydrocarbons con-taining nine carbon atoms or more.5.2 This method may not detect all components and theremay be unknown components that would be assigned inappro-priate response factors and thus, the results may not beabsolute.6. Int
21、erferences6.1 In some cases for toluene, mixed xylenes, p-xylene,o-xylene, ethylbenzene and styrene, it may be difficult toresolve benzene from the nonaromatic hydrocarbons. There-fore the concentrations are determined as a composite. In theevent that the benzene concentration must be determined, an
22、alternate method such as Test Method D6229 must be selectedto ensure an accurate assessment of the benzene concentration.6.2 The complete separation of p-xylene from ethylbenzene,or ethylbenzene and m-xylene from p-xylene can be difficultwhen either ethylbenzene or p-xylene is analyzed, respectively
23、.The separation can be considered adequate if the distance fromthe baseline to the valley between the two peaks is not greaterthan 50 % of the peak height of lower of the two peaks.7. Apparatus7.1 Chromatographic data system is required.7.2 ColumnsThe choice of column is based on resolutionrequireme
24、nts. Any column may be used that is capable ofresolving all significant impurities from the major component.The column and conditions described in Table 1 have beenused successfully and shall be used as a referee in cases ofdispute.7.3 Gas ChromatographAny instrument having a flameionization detecto
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD750420150379STANDARDTESTMETHODFORTRACEIMPURITIESINMONOCYCLICAROMATICHYDROCARBONSBYGASCHROMATOGRAPHYANDEFFECTIVECARBONNUMBER

链接地址:http://www.mydoc123.com/p-525684.html