《ASTM D7120 D7120M-2010 7500 Standard Guide for Evaluation and Preparation of Roof Membranes for Coating Application《涂料施涂用屋顶薄膜的评定和编制的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7120 D7120M-2010 7500 Standard Guide for Evaluation and Preparation of Roof Membranes for Coating Application《涂料施涂用屋顶薄膜的评定和编制的标准指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7120/D7120M 10Standard Guide forEvaluation and Preparation of Roof Membranes for CoatingApplication1This standard is issued under the fixed designation D7120/D7120M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the procedures for evaluating andpreparing non-aggregate surfaced membranes for the applica
3、-tion of a coating. It does not address design, construction, orinstallation issues regarding the roof assembly or the roofmembrane. It is not an application guide for roof coatings.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stat
4、ed ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
5、 It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 adequate drainage, nthe drainage condition inwhich consideration has been made for a
6、ll loading deflectionsof the deck, and additional roof slope has been provided toensure drainage of the roof area within 48 h of rainfall.2.1.2 contaminant, nany substance which will adverselyeffect the adhesion of a coating.2.2 Contaminant List:2.2.1 air/water-borne surface contaminant, nany of sev
7、-eral types of external source contaminants that accumulate ontop surface of a roof. Surface contaminants come from one ofthe following sources: (1) particulate and liquid emissions frombuilding interior operations, (2) airborne vegetable and mineralparticles, and (3) oils, greases, and chemicals fr
8、om industrialand food service operations.2.2.2 chemical barrier, na barrier formed by reactivematerials either acid, alkali, or solvent, which inhibits theadhesion of surface coatings.2.2.3 exudate, na glossy film that forms on the surface ofan atactic polypropylene (APP) membrane. Exudates inhibitc
9、oating adhesion and they can bleed through and stain thecoating surface.2.2.4 loose mineral granules, nsee mineral granules,disattached mineral granules.2.2.5 moisture, nsurfaces to be coated must be clean anddry.2.2.6 organic barrier, nsee organic, any of several bio-logical growths, usually algae
10、or fungus, which act as a barrierbetween an APP roof membrane and a coating.2.2.7 release and/or anti-block agent, nsee parting agent,any of several mineral or waxy materials which are typicallyapplied to an APP sheet during the manufacturing process toprevent the sheet from sticking to itself while
11、 in the roll.2.2.8 surface oxidate, na barrier film, which forms on thesurface of an unprotected smoothAPP sheet during weathering.3. Significance and Use3.1 This guide outlines the general procedures necessary toevaluate and prepare a roof membrane for the application of aliquid surface coating.3.2
12、 This guide is not all inclusive; this guide is intended tosupplement detailed instructions from manufacturers andsafety requirements required by law.4. General Surface Conditions4.1 Lack of adequate drainage will have an adverse effect onroof components and will lead to premature failure of liquida
13、pplied coatings.4.2 It is important to determine the area(s) affected byadverse surface conditions. Specific surface preparation op-tions can be determined after the membrane has been evaluatedand subsequent adhesion tests performed.4.3 Multiple surface preparation techniques may be requiredto prepa
14、re the surface of an APP modified bitumen to receivea coating.1This guide is under the jurisdiction of ASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.20 on RoofingMembrane Systems.Current edition approved July 1, 2010. Published July 2010. DOI: 10
15、.1520/D7120_D7120M-10.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Roof Surface Evaluation5.1 The roof membrane surface evaluation shall be con-ducted prior to the application of a surface coating. Surfaceevaluation will assist
16、 in determining the type of preparationrequired to achieve adhesion between the coating and the APPmodified bitumen material.5.1.1 Remove anything that will inhibit the adhesion of thecoating.5.1.2 Perform a “cloth tape evaluation” to determine thepresence and type of contaminants on the roof surfac
17、e accord-ing to the following procedure. On large surfaces, evaluateseveral locations.5.1.3 Avoid making evaluations on windy days or whenmoisture is present in any form.5.1.4 Clean the roof surface, as necessary, by the methodappropriate methods in Section 6.5.1.4.1 White Cloth Evaluation:5.1.4.2 M
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7120D7120M20107500STANDARDGUIDEFOREVALUATIONANDPREPARATIONOFROOFMEMBRANESFORCOATINGAPPLICATION 涂料

链接地址:http://www.mydoc123.com/p-524546.html