ASTM D6918-2003(2007) Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition《在挤压状况下检测带钢制竖排水管的标准试验方法》.pdf
《ASTM D6918-2003(2007) Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition《在挤压状况下检测带钢制竖排水管的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6918-2003(2007) Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition《在挤压状况下检测带钢制竖排水管的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6918 03 (Reapproved 2007)Standard Test Method forTesting Vertical Strip Drains in the Crimped Condition1This standard is issued under the fixed designation D 6918; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is a performance test, which measuresthe effect crimping, has on the ability of vertical str
3、ip drains totransmit water parallel to the plane of the drain.1.2 This test method is applicable to all vertical strip drains.1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
4、It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 4354 Practice for Sampling of Geosynthetics for Testing3. Terminology3.1 Def
5、initions:3.1.1 geocomposite, na product composed of two or morematerials, at least one of which is a geosynthetic.3.1.2 geosynthetics, na planar product manufactured frompolymeric materials used with soil, rock, earth, or othergeotechnical engineering related material as an integral part ofa man-mad
6、e project, structure, or system.3.1.3 geotextile, na permeable geosynthetic comprisedsolely of textiles.3.1.3.1 DiscussionGeotextiles perform several functionsin geotechnical engineering applications, including: separation,filtration, drainage, reinforcement, and protection.3.1.4 vertical strip drai
7、n, na geocomposite consisting of ageotextile cover and drainage core installed vertically into soilto provide drainage for accelerated consolidation of soils.4. Summary of Test Method4.1 This test method describes procedures for determiningthe effect of a crimp forming in the vertical strip drain du
8、e theconsolidation of soils around it in the field.4.1.1 Avertical strip drain is sealed in a cover of heat shrinkplastic to prevent any water from escaping out through thegeotextile during the test.4.1.2 The sealed vertical strip drain is placed in the crimpingdevice (See Fig. 1) and water is allow
9、ed to pass through itunder a constant head of water.4.1.3 A 90 crimp is placed on the specimen, and waterallowed to pass through it under a constant head in the crimpedcondition.4.1.4 The flow rate of water along the plane of the un-crimped vertical strip drain is compared to the flow rate in thecri
10、mped condition.5. Significance and Use5.1 This test method is considered satisfactory for theacceptance of commercial shipments of vertical strip drains.5.1.1 In case of dispute arising from differences in reportedtest results when using this test method for acceptance testingof commercial shipments
11、, the purchaser and the suppliershould conduct comparative tests to determine if there is anystatistical bias between their laboratories. Competent statisticalassistance is recommended for the investigation of bias. As aminimum, the two parties should take a group of test speci-mens that as homogeno
12、us as possible, and that are from a lot ofmaterial of the type in question. The test specimens should berandomly assigned in numbers to each laboratory for testing.The average results from the two laboratories should becompared using Students t-test for unpaired data and anacceptable probability lev
13、el chosen by the two parties beforethe start of testing. If a bias is found, either its cause must befound and corrected, or the purchaser and the supplier mustagree to interpret future test results in light of the known bias.1This test method is under the jurisdiction of ASTM Committee D35 onGeosyn
14、thetics and is the direct responsibility of Subcommittee D35.03 on Perme-ability and Filtration.Current edition approved June 1, 2007. Published July 2007. Originally approvedin 2003. Last previous edition approved in 2003 as D 691803.2For referenced ASTM standards, visit the ASTM website, www.astm.
15、org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Vertica
16、l strip drains are installed in areas where it isdesired to increase the rate of soil consolidation. It has beenshown that as the soil around the vertical strip drain consoli-dates, a crimp may form in the vertical strip drain due to themovement of the drain in the area of soil consolidation.5.3 Thi
17、s test method can be used to evaluate if there is anyreduction in flow rate of water through the drain due to thecrimping, and what effect, if any, this crimping may have onthe rate of consolidation of the soil.6. Apparatus6.1 The test device must be capable of maintaining aconstant head of water on
18、 the vertical strip drain being tested.The apparatus consists of a water chamber assembly, a speci-men holder, and a crimping wedge, all of which are attached toa holding stand. See Fig. 2.6.2 Container, for collecting the water as it flows throughthe vertical strip drain.6.3 Stopwatch or Electronic
19、 Timing Device, connected tothe collection container, for timing the flow of water throughthe vertical strip drain.6.4 Blow Dryer, used for applying heat to the heat shrink-wrap that is placed around the test specimen prior to testing.7. Materials7.1 Heat Shrink Plastic WrapThe heat shrink plasticwr
20、ap, of the type used in homes for sealing windows fromwind drafts, is used to seal the vertical strip drain so that waterdoes not flow out through the geotextile wrap on the core. Thewater is to flow in a parallel plan to the fabric, along the corematerial of the drain.7.2 Bathtub Caulkthe caulk is
21、used to seal the testspecimen into the water chamber assembly as directed in 12.2.8. Hazards8.1 There are no known hazards either with the materials, orin performing this test.9. Sampling, Test Specimens, and Test Units9.1 Division into Lots and Lot SamplesDivide the mate-rial into lots and take a l
22、ot sample as directed in PracticeD 4354. Rolls of prefabricated vertical strip drains are theprimary sampling unit.9.2 Laboratory SampleRemove the outer wrap of drainmaterial from the roll to avoid sampling and testing anymaterial, which may have been damaged during storage. Takefor the laboratory s
23、ample a 1830 mm (6 ft) length of the drainmaterial.9.3 Test SpecimensFrom the laboratory sample takenfrom each lot, cut test specimens as directed in 10. Each testspecimen shall be 610 mm (2 ft) long.10. Number of Specimens10.1 Unless otherwise agreed upon, as when provided in anapplicable material
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD691820032007STANDARDTESTMETHODFORTESTINGVERTICALSTRIPDRAINSINTHECRIMPEDCONDITION 挤压 状况 检测 钢制 竖排

链接地址:http://www.mydoc123.com/p-523976.html