《ASTM D6296-1998(2008) 346 Standard Test Method for Total Olefins in Spark-ignition Engine Fuels by Multidimensional Gas Chromatography《用多维气相色谱法测定火花点火发动机燃料中总烯烃的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6296-1998(2008) 346 Standard Test Method for Total Olefins in Spark-ignition Engine Fuels by Multidimensional Gas Chromatography《用多维气相色谱法测定火花点火发动机燃料中总烯烃的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6296 98 (Reapproved 2008)An American National StandardStandard Test Method forTotal Olefins in Spark-ignition Engine Fuels byMultidimensional Gas Chromatography1This standard is issued under the fixed designation D 6296; the number immediately following the designation indicates the y
2、ear oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides for the quantitative determ
3、i-nation of total olefins in the C4to C10range in spark-ignitionengine fuels or related hydrocarbon streams, such as naphthasand cracked naphthas. Olefin concentrations in the range from0.2 to 5.0 liquid-volume % or mass %, or both, can bedetermined directly on the as-received sample whereas olefins
4、in samples containing higher concentrations are determinedafter appropriate sample dilution prior to analysis.1.2 This test method is applicable to samples containingalcohols and ethers; however, samples containing greater than15 % alcohol must be diluted. Samples containing greater than5.0 % ether
5、must also be diluted to the 5.0 % or less level, priorto analysis. When ethyl-tert-butylether is present, only olefinsin the C4to C9range can be determined.1.3 This test method can not be used to determine individualolefin components.1.4 This test method can not be used to determine olefinshaving hi
6、gher carbon numbers than C10.NOTE 1Precision was determined only on samples containing MTBEand ethanol.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,
7、if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1319 Test Method for Hydrocarbon Types in L
8、iquidPetroleum Products by Fluorescent Indicator AdsorptionD 4052 Test Method for Density and Relative Density ofLiquids by Digital Density MeterD 4307 Practice for Preparation of Liquid Blends for Use asAnalytical StandardsD 4815 Test Method for Determination of MTBE, ETBE,TAME, DIPE, tertiary-Amyl
9、 Alcohol and C1to C4Alco-hols in Gasoline by Gas ChromatographyD 5599 Test Method for Determination of Oxygenates inGasoline by Gas Chromatography and Oxygen SelectiveFlame Ionization Detection3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 trap, na device utilized to selectiv
10、ely retain specificportions (individual or groups of hydrocarbons or oxygenates)of the test sample and to release the retained components byincreasing the trap temperature.3.2 Acronyms:3.2.1 ETBEethyl-tert-butylether.3.2.2 MTBEmethyl-tertbutylether.4. Summary of Test Method4.1 A reproducible 0.2-L v
11、olume of a representativesample, or a dilution thereof, is introduced into a computercontrolled gas chromatographic system3consisting of a seriesof columns, traps, and switching valves operating at varioustemperatures. The valves are actuated at predetermined timesto direct portions of the sample to
12、 appropriate columns andtraps. The sample first passes through a polar column thatretains C12+ hydrocarbons, all aromatics, C11+ olefins, andsome alcohols, all of which are subsequently backflushed tovent. The fraction eluting from the polar column, whichcontains C11and lower boiling saturated hydro
13、carbons as wellas decene and lower boiling olefins, enters an ether/alcohol trapwhere the ethers and alcohols are selectively retained and alsosubsequently backflushed. The fraction eluting from the ether/1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubr
14、icants and is the direct responsibility of SubcommitteeD02.04.0L on Gas Chromatography Methods.Current edition approved May 1, 2008. Published September 2008. Originallyapproved in 1998. Last previous edition approved in 2003 as D 629698(2003)1.2For referenced ASTM standards, visit the ASTM website,
15、 www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of supply of apparatus known to the committee at this time, theAC FTO Analyzer, is AC Analytical Co
16、ntrols, Inc., 3494 Progress Dr., Bensalem,PA 19020. If you are aware of alternative suppliers, please provide this informationto ASTM Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,1which you may attend.1Copyright ASTM International,
17、 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.alcohol trap, which consists of C11and lower boiling saturatedhydrocarbons and the olefins, enters an olefin trap. The olefinsare selectively retained while the saturated hydrocarbons elute,pass through a nonpolar c
18、olumn, and are detected by a flameionization detector (FID). When the saturated hydrocarbonshave completely eluted to the FID, the nonpolar column ovenis cooled and the olefins, which have been retained on theolefin trap, are desorbed by heating. The desorbed olefins enterand elute from the nonpolar
19、 column, which is temperatureprogrammed to separate the olefins by boiling point, and aredetected by the FID.NOTE 2Separation of olefins by boiling point is necessary for thecalculation of the volume % of the olefins because the density of lowboiling olefins differs from that of high boiling olefins
20、 and, therefore, adensity correction must be applied.4.2 Quantitation of the detected olefin peak areas to providevolume % or mass %, or both, is accomplished through the useof an external standard followed by the application of flameionization detector response factors. The quantitation alsotakes i
21、nto consideration the baseline compensation, sampledilution, and density corrections.5. Significance and Use5.1 The quantitative determination of olefins in spark-ignition engine fuels is required to comply with governmentregulations.5.2 Knowledge of the total olefin content provides a meansto monit
22、or the efficiency of catalytic cracking processes.5.3 This test method provides better precision for olefincontent than Test Method D 1319. It also provides data in amuch shorter time, approximately 20 min following calibra-tion, and maximizes automation to reduce operator labor.5.4 This test method
23、 is not applicable to M85 or E85 fuels,which contain 85 % methanol and ethanol, respectively.6. Interferences6.1 Some types of sulfur-containing compounds are irre-versibly absorbed in the olefin and oxygenate traps ultimatelyreducing the trap capacity. However, a variety of spark-ignitionengine fue
24、ls have been analyzed without significant perfor-mance deterioration of these traps.6.2 Commercial dyes used to distinguish between gradesand types of spark-ignition engine fuels have not been found tointerfere with this test method.6.3 Commercial detergent additives utilized in spark-ignition engin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD629619982008346STANDARDTESTMETHODFORTOTALOLEFINSINSPARKIGNITIONENGINEFUELSBYMULTIDIMENSIONALGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-522084.html