《ASTM D6132-2004 Standard Test Method for Nondestructive Measurement of Dry Film Thickness of Applied Organic Coatings Using an Ultrasonic Gage《用超声波仪表对外施的有机涂层的干膜厚度进行无损测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6132-2004 Standard Test Method for Nondestructive Measurement of Dry Film Thickness of Applied Organic Coatings Using an Ultrasonic Gage《用超声波仪表对外施的有机涂层的干膜厚度进行无损测量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6132 04Standard Test Method forNondestructive Measurement of Dry Film Thickness ofApplied Organic Coatings Using an Ultrasonic Gage1This standard is issued under the fixed designation D 6132; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the use of ultrasonic filmthickness gages to measure acc
3、urately and nondestructively thedry film thickness of organic coatings applied over a substrateof dissimilar material. Measurements may be made on fieldstructures, on commercially manufactured products, or onlaboratory test specimens. These types of gages can accuratelymeasure the dry film thickness
4、 of organic coatings on concrete,wood and wallboard substrates.1.2 This test method is not applicable to coatings that willbe readily deformable under load of the measuring instrumentas the instrument probe is placed directly on the coating surfaceto take a reading.1.3 The effective range of instrum
5、ents using the principle ofultrasonics is limited by gage design. A thickness range of 0.3to 600 mils (8 m to 15 mm) has been demonstrated.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport t
6、o address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 823 Practices for
7、 Producing Films of Uniform Thicknessof Paint, Varnish, and Related Products on Test PanelsD 1005 Test Method for Measurement of Dry-Film Thick-ness of Organic Coatings Using MicrometersD 4138 Test Method for Measurement of Dry Film Thick-ness of Protective Coating Systems by Destructive MeansE 691
8、Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 SSPC The Society for Protective Coatings Standard:SSPC-PA2 Measurement of Dry Coating Thickness withMagnetic Gages33. Summary of Test Method3.1 Instruments complying with this test method measurethickness
9、by emitting an ultrasonic pulse into the coating thatis reflected back from the substrate to the probe. The traveltime is converted into a thickness reading. The instrument mustbe placed directly on the coating surface to take a reading.3.2 After verifying accuracy on a known coated part of theobjec
10、t or material of the same kind, the instrument probe iscoupled with the coated specimen, after proper cure andconditioning according to the coating manufacturers instruc-tions.3.3 It should be recognized that the accuracy of the mea-surements can be influenced when:3.3.1 The coated object to be meas
11、ured is not planar withrespect to the transducer face at the point of measurement,3.3.2 The surface roughness of the coated specimen exceedsthe coating thickness, and3.3.3 Coating density is not uniform.4. Significance and Use4.1 Many coating properties are markedly affected by thefilm thickness of
12、the dry film such as adhesion, flexibility, andhardness. To be able to compare results obtained by differentoperators, it is essential to measure film thickness carefully.4.2 Most protective and high performance coatings areapplied to meet a requirement or a specification for the dry-filmthickness o
13、f each coat, or for the complete system, or both.Coatings must be applied within certain minimum and maxi-mum thickness tolerances in order that they can fulfill theirintended function. In addition to potential performance defi-ciencies, it is uneconomical to apply more material thannecessary when c
14、oating large areas such as floors and walls.4.3 Surface roughness can affect the accuracy of this testmethod. A rough surface has a tendency to scatter the ultra-sonic pulse and odd readings may occur occasionally.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related
15、Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.23 on Physical Properties of Applied Paint Films.Current edition approved June 1, 2004. Published June 2004. Originallyapproved in 1997. Last previously edition approved in 1997 as D 6132 97.2For referenced AST
16、M standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from SSPC: The Society for Protective Coatings, 40 24th Street, 6thFl
17、oor, Pittsburgh PA 15222-4656.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.4 This test method may not be applicable to measureorganic coating thickness on all sub
18、strates. The instrumentsability to detect a distinct interface between the coating and thesubstrate may be impeded if the coating and the substrate areof similar composition of if the coating is non-homogeneous.Verify operation on a known thickness of the coating/substratecombination if these circum
19、stances are thought to exist.4.5 Multilayered coatings have many interfaces and theinstrument will measure to the interface separating the twomost acoustically different materials. Some instruments havethe ability to detect and measure the individual layer thick-nesses in a multi-layer system.4.6 Th
20、e use of this test method is not necessarily limited bythe type of substrate material as nondestructive magnetic-typeor eddy current means.5. Apparatus5.1 Ultrasonic Gage4an electronic gage with a transducerusing an ultrasonic principle and numerical techniques (seeFig. 1).6. Test Specimen6.1 When t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD61322004STANDARDTESTMETHODFORNONDESTRUCTIVEMEASUREMENTOFDRYFILMTHICKNESSOFAPPLIEDORGANICCOATINGSUSINGANULTRASONICGAGE

链接地址:http://www.mydoc123.com/p-521643.html