ASTM D5453-2008 952 Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons Spark Ignition Engine Fuel Diesel Engine Fuel and Engine Oil by Ultraviolet Fluores.pdf
《ASTM D5453-2008 952 Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons Spark Ignition Engine Fuel Diesel Engine Fuel and Engine Oil by Ultraviolet Fluores.pdf》由会员分享,可在线阅读,更多相关《ASTM D5453-2008 952 Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons Spark Ignition Engine Fuel Diesel Engine Fuel and Engine Oil by Ultraviolet Fluores.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5453 08bAn American National StandardStandard Test Method forDetermination of Total Sulfur in Light Hydrocarbons, SparkIgnition Engine Fuel, Diesel Engine Fuel, and Engine Oil byUltraviolet Fluorescence1This standard is issued under the fixed designation D 5453; the number immediately
2、 following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test
3、method covers the determination of total sulfurin liquid hydrocarbons, boiling in the range from approxi-mately 25 to 400C, with viscosities between approximately0.2 and 20 cSt (mm2/S) at room temperature.1.2 Three separate interlaboratory studies (ILS) on preci-sion, and three other investigations
4、that resulted in an ASTMresearch report, have determined that this test method isapplicable to naphthas, distillates, engine oil, ethanol, FattyAcid Methyl Ester (FAME), and engine fuel such as gasoline,oxygen enriched gasoline (ethanol blends, E-85, M-85, RFG),diesel, biodiesel, diesel/biodiesel bl
5、ends, and jet fuel. Samplescontaining 1.0 to 8000 mg/kg total sulfur can be analyzed(Note 1).NOTE 1Estimates of the pooled limit of quantification (PLOQ) for theprecision studies were calculated. Values ranged between less than 1.0 andless than 5.0 mg/kg (see Section 8 and 15.1).1.3 This test method
6、 is applicable for total sulfur determi-nation in liquid hydrocarbons containing less than 0.35 %(m/m) halogen(s).1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety
7、 concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For warningstatements, see 3.1, 6.3, 6.4, Section 7, and 8.1.2. Referenced D
8、ocuments2.1 ASTM Standards:2D 1298 Test Method for Density, Relative Density (SpecificGravity), or API Gravity of Crude Petroleum and LiquidPetroleum Products by Hydrometer MethodD 4052 Test Method for Density and Relative Density ofLiquids by Digital Density MeterD 4057 Practice for Manual Sampling
9、 of Petroleum andPetroleum ProductsD 4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD 6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System Performance3. Summary of Test Method3.1 A hydrocarbon sample
10、is either directly injected orplaced in a sample boat. The sample or boat, or both, is insertedinto a high temperature combustion tube where the sulfur isoxidized to sulfur dioxide (SO2) in an oxygen rich atmosphere.Water produced during the sample combustion is removed andthe sample combustion gase
11、s are next exposed to ultraviolet(UV) light. The SO2absorbs the energy from the UV light andis converted to excited sulfur dioxide (SO2*). The fluorescenceemitted from the excited SO2* as it returns to a stable state,SO2, is detected by a photomultiplier tube and the resultingsignal is a measure of
12、the sulfur contained in the sample.(WarningExposure to excessive quantities of ultraviolet(UV) light is injurious to health. The operator must avoidexposing any part of their person, especially their eyes, notonly to direct UV light but also to secondary or scatteredradiation that is present.)1This
13、test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.03.01 on Atomic Absorption Methods.Current edition approved July 1, 2008. Published August 2008. Originallyapproved in 1993. Last previous edition appro
14、ved in 2008 as D 545308a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appea
15、rs at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Significance and Use4.1 Some process catalysts used in petroleum and chemicalrefining can be poisoned when trace amounts of sulfur bearingmaterials are
16、contained in the feedstocks. This test method canbe used to determine sulfur in process feeds sulfur in finishedproducts, and can also be used for purposes of regulatorycontrol.5. Apparatus5.1 FurnaceAn electric furnace held at a temperature(1075 6 25C) sufficient to pyrolyze all of the sample andox
17、idize sulfur to SO2.5.2 Combustion TubeA quartz combustion tube con-structed to allow the direct injection of the sample into theheated oxidation zone of the furnace or constructed so that theinlet end of the tube is large enough to accommodate a quartzsample boat. The combustion tube must have side
18、 arms for theintroduction of oxygen and carrier gas. The oxidation sectionshall be large enough (see Fig. 1) to ensure complete combus-tion of the sample. Fig. 1 depicts conventional combustiontubes. Other configurations are acceptable if precision is notdegraded.5.3 Flow ControlThe apparatus must b
19、e equipped withflow controllers capable of maintaining a constant supply ofoxygen and carrier gas.5.4 Drier TubeThe apparatus must be equipped with amechanism for the removal of water vapor. The oxidationreaction produces water vapor which must be eliminated priorto measurement by the detector. This
20、 can be accomplished witha membrane drying tube, or a permeation dryer, that utilizes aselective capillary action for water removal.5.5 UV Fluorescence DetectorA qualitative and quantita-tive detector capable of measuring light emitted from thefluorescence of sulfur dioxide by UV light.5.6 Microlitr
21、e SyringeA microlitre syringe capable ofaccurately delivering 5 to 20-L quantities. The needle shall be50 mm (65 mm) long.5.7 Sample Inlet SystemEither of two types of sampleinlet systems can be used.5.7.1 Direct InjectionA direct injection inlet system mustbe capable of allowing the quantitative de
22、livery of the materialto be analyzed into an inlet carrier stream which directs thesample into the oxidation zone at a controlled and repeatablerate. A syringe drive mechanism which discharges the samplefrom the microlitre syringe at a rate of approximately 1 L/s isrequired. For example, see Fig. 2.
23、5.7.2 Boat Inlet SystemAn extended combustion tubeprovides a seal to the inlet of the oxidation area and is swept bya carrier gas. The system provides an area to position thesample carrying mechanism (boat) at a retracted positionFIG. 1 Conventional Combustion TubesD 5453 08b2removed from the furnac
24、e. The boat drive mechanism willfully insert the boat into the hottest section of the furnace inlet.The sample boats and combustion tube are constructed ofquartz. The combustion tube provides a cooling jacket for thearea in which the retracted boat rests awaiting sample intro-duction from a microlit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD54532008952STANDARDTESTMETHODFORDETERMINATIONOFTOTALSULFURINLIGHTHYDROCARBONSSPARKIGNITIONENGINEFUELDIESELENGINEFUELANDENGINEOILBYULTRAVIOLETFLUORESPDF

链接地址:http://www.mydoc123.com/p-519832.html