ASTM D5241-1992(2004) Standard Practice for Micro-Extraction of Water for Analysis of Volatile and Semi-Volatile Organic Compounds in Water《水中挥发的和类似挥发有机化合物分析用水的微量萃取法的标准操作规程》.pdf
《ASTM D5241-1992(2004) Standard Practice for Micro-Extraction of Water for Analysis of Volatile and Semi-Volatile Organic Compounds in Water《水中挥发的和类似挥发有机化合物分析用水的微量萃取法的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5241-1992(2004) Standard Practice for Micro-Extraction of Water for Analysis of Volatile and Semi-Volatile Organic Compounds in Water《水中挥发的和类似挥发有机化合物分析用水的微量萃取法的标准操作规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5241 92 (Reapproved 2004)Standard Practice forMicro-Extraction of Water for Analysis of Volatile and Semi-Volatile Organic Compounds in Water1This standard is issued under the fixed designation D 5241; the number immediately following the designation indicates the year oforiginal adop
2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers standard procedures for extractionof volatile and
3、semi-volatile organic compounds from waterusing small volumes of solvents.1.2 The compounds of interest must have a greater solubil-ity in the organic solvent than the water phase.1.3 Not all of the solvents that can be used in microextraction are addressed in this practice. The applicability of aso
4、lvent to extract the compound(s) of interest must be demon-strated before use.1.4 This practice provides sample extracts suitable for anytechnique amenable to solvent injection such as gas chroma-tography or high performance liquid chromatography (HPLC).1.5 The values stated in SI units are to be re
5、garded as thestandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
6、to use. For specific hazardstatements, see Section 9.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 1193 Specification for Reagent WaterD 3370 Practices for Sampling Water from Closed ConduitsD 3694 Practices for Preparation of Sample Containers andfor Preservation
7、of Organic ConstituentsD 3856 Guide for Good Laboratory Practice in LaboratoriesEngaged in Sampling and Analysis of Water and Waste-waterD 3973 Test Method for Low-Molecular Weight Haloge-nated Hydrocarbons in WaterD 4210 Practice for Intralaboratory Quality Control Proce-dures and a Discussion on R
8、eporting Low-Level Data3D 4448 Guide for Sampling Groundwater Monitoring WellsD 5175 Test Method for Organohalide Pesticides and Poly-chlorinated Biphenyls in Water by Microextraction andGas Chromatography3. Summary of Practice3.1 This practice employs liquid/liquid extraction to isolatecompounds of
9、 interest. The sample is added to an extractiondevice. The solvent may be added to the sample container or anextraction device and extracted for a period of 5 min. Thesolvent is then ready for analysis. If required, the pH may beadjusted and salt may be added prior to extraction to increasethe extra
10、ction specificity and efficiency.3.2 The solvent extract may be further processed usingsample clean-up and concentration techniques. The analytes inthe solvent may be analyzed using instrumental methods forspecific volatile or semivolatile organic compounds. Thispractice does not include sample extr
11、act clean-up methods.4. Significance and Use4.1 This practice provides a general procedure for thesolvent extraction of volatile and semi-volatile organic com-pounds from a water matrix. Solvent extraction is used as theinitial step in the solvent extraction of organic constituents forthe purpose of
12、 quantifying extractable organic compounds.4.2 Typical detection limits that can be achieved usingmicro-extraction techniques with gas chromatography (GC)with flame ionization detector (FID), electron capture detector(ECD), or with a mass spectrometer (GC/MS) range frommilligrams per litre (mg/L) to
13、 nanograms per litre (ng/L). Thedetection limit, linear concentration range, and sensitivity ofthe test method for a specific organic compound will dependupon the sample clean-up, injection volume, solvent to sampleratio, solvent concentration methods used, and the determina-tive technique employed.
14、4.3 Micro-extraction has the advantage of speed, simpleextraction devices, and the use of small amounts of sample andsolvents.1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.06 on Methods for Analysis forOrganic Substances i
15、n Water.Current edition approved June 1, 2004. Published June 2004. Originallyapproved in 1992. Last previous edition approved in 1998 as D 5241 92 (1998).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM
16、Standards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3.1 Selectivity can be improved by the choice of solvent(usually hexane or pent
17、ane) or mixed solvents, extraction timeand temperature, and ionic strength of the solution.4.3.2 Extraction devices can vary from the sample containeritself to commercial devices specifically designed for micro-extraction. See 7.1 and 7.2.4.3.3 A list of chlorinated organic compounds that can bedete
18、rmined by this practice includes both high and low boilingcompounds or chemicals (see Table 1).5. Interferences5.1 Solvents, reagents, glassware, and other sample process-ing hardware may yield discrete artifacts or elevated baselinesthat can cause poor precision and accuracy. See TerminologyD 1129.
19、5.1.1 Glassware should be washed with detergent, rinsedwith water, followed by a rinse with distilled in glass acetone.Final drying is done by air or 103C oven. Additional cleaningsteps may be required when the analysis requires levels ofmicrograms per litre or below. Once the glassware has beenclea
20、ned, it should be used immediately or stored wrapped inaluminum foil (shiny side out) or by stretching a sheet ofPTFE-fluorocarbon over the top for storage.5.1.2 Plastics other than PTFE-fluorocarbon should beavoided. They are a significant source of interference and canadsorb some organics.5.1.3 A
21、field blank prepared from water and carried throughsampling, subsequent storage, and handling can serve as acheck on sources of interferences from the containers.5.2 When performing analyses for specific organic com-pounds, matrix interferences may be caused by materials andconstituents that are coe
22、xtracted from the sample. The extent ofsuch matrix interferences will vary considerably depending onthe sample and the specific instrumental analysis method used.Matrix interferences may be reduced by the choice of extract-ing solvent, or by using a clean-up technique on the extract.6. Selection of
23、the Extraction Solvent6.1 The selection of solvent for extraction will depend uponmany factors, including the following:6.1.1 Solvent compatibility with analytical instrumentation,6.1.2 Solubility of the organic constituent in the solventversus its solubility in water. The water/solvent ratio has be
24、enfound to be critical to achieve optimum recovery of someanalytes (see Test Method D 3973). Typical solvent to sampleratios are 1 to 10 or 20. The ratio should be optimized formaximum recovery or detection of an analyte, or both,6.1.3 The availability and purity of the solvent,6.1.4 The boiling poi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD524119922004STANDARDPRACTICEFORMICROEXTRACTIONOFWATERFORANALYSISOFVOLATILEANDSEMIVOLATILEORGANICCOMPOUNDSINWATER

链接地址:http://www.mydoc123.com/p-519257.html