《ASTM D5176-2008(2015) Standard Test Method for Total Chemically Bound Nitrogen in Water by Pyrolysis and Chemiluminescence Detection《采用热解和化学发光检测法测定水中化学键合氮总量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5176-2008(2015) Standard Test Method for Total Chemically Bound Nitrogen in Water by Pyrolysis and Chemiluminescence Detection《采用热解和化学发光检测法测定水中化学键合氮总量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5176 08 (Reapproved 2015)Standard Test Method forTotal Chemically Bound Nitrogen in Water by Pyrolysis andChemiluminescence Detection1This standard is issued under the fixed designation D5176; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the totalnitrogen content of water in
3、 concentrations from 0.5 to 1000mg/L. Higher nitrogen concentrations may be determined bymaking the proper dilutions.1.2 This test method does not determine molecular nitrogen(N2).1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstand
4、ard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenc
5、ed Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on Water3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this standard, refer
6、toTerminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 total chemically bound nitrogen, nall inorganic andorganic nitrogen in the sample, except molecular nitrogen (N2).4. Summary of Test Method4.1 The sample of water is introduced into a stream ofoxygen or inert/oxygen mix flo
7、wing through a quartz pyrolysistube. Oxidative pyrolysis converts chemically bound nitrogento nitric oxide (NO). The gas stream is dried and the NO iscontacted with ozone (O3) producing metastable nitrogendioxide (NO2*). As the NO2* decays, light is emitted anddetected by a photomultiplier tube. The
8、 resulting signal is ameasure of the total chemically bound nitrogen in the sample.5. Significance and Use5.1 This test method is useful for the determination of totalchemically bound nitrogen in wastewaters and other waters.6. Apparatus36.1 Pyrolysis FurnaceAn electric tube furnace capable ofachiev
9、ing a temperature of 1100C. The furnace may be singleor multizoned and may have common or separate and inde-pendent temperature controls.6.2 Pyrolysis TubeThe pyrolysis tube must be fabricatedfrom quartz and should be designed to ensure completepyrolysis of a wide variety of samples.6.3 Chemilumines
10、cence DetectorThe detector shall have aphotomultiplier tube capable of sensing the light emission ofthe decaying NO2*. The detector shall have digital display,onboard ozone generator and analog output for data system orstrip chart recorder.6.4 Recorder (optional)The recorder shall be able toaccept a
11、 1 V full scale signal and to provide a chart speed of 1cm/min.6.5 Microlitre SyringeAny standard series of microlitresyringes with stainless steel needles is acceptable. See manu-facturers instructions for appropriate syringe sizes.6.6 Syringe Drive MechanismThe syringe drive shall becapable of dri
12、ving the sample from a microlitre syringe at acontrolled, reproducible rate.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved June 15, 2015.
13、Published June 2015. Originallyapproved in 1991. Last previous edition approved in 2008 as D5176 08. DOI:10.1520/D5176-08R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information,
14、refer to the standards Document Summary page onthe ASTM website.3The apparatus described in 6.1 6.7 is manufactured by Antek Instruments,Inc., Houston, TX and Dohrmann Division of Rosemount Analytical Inc., SantaClara, CA, and was used in the validation study of this test method.Copyright ASTM Inter
15、national, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.7 Sample BoatSamples with high concentrations ofsuspended matter or dissolved nonvolatile compounds maytend to plug the syringe needle upon injection into the pyrolysistube. In this case a sample boat of
16、quartz or platinum, with orwithout quartz wool, should be used, in conjunction with theappropriate pyrolysis tube. The pyrolysis tube shall allow theintroduction of the sample into the boat by microlitre syringewithout interrupting the gas flow system.7. Reagents and Materials7.1 Purity of ReagentsR
17、eagent grade chemicals shall beused. Unless otherwise indicated, it is intended that all reagentsshall conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society.4Other grades may be used, provided it is first determined thatthe reagent is of sufficiently h
18、igh purity to permit its usewithout lessening the accuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water that meetsthe purity specifications of Type I or Type II water, presentedin Specification D1193.7.3 Inert Gas, A
19、rgon (minimum purity 99.99 %).7.4 Oxygen (minimum purity 99.6 %).7.5 Stock Solution, Pyridine (10 000 mg N/L)Prepare byaccurately weighing 5.647 g of pyridine into a 100 mLvolumetric flask and dilute to 100 mL with water.7.6 Pyridine Solutions, Standard (1000, 500, 100, 50, 10, 5,1, and 0.5 mg N/L)D
20、ilute ten volumes of the stock solution(see 6.5) with 90 volumes of water to prepare a 1000 mg N/Lstandard. Similarly, by serial dilution with water, prepare 500,100, 50, 10, 5, 1, and 0.5 mg N/L standards.8. Preparation of Apparatus8.1 Assemble apparatus according to manufacturers in-structions.9.
21、Calibration and Standardization9.1 Use the water that was used to prepare the standards asa zero blank standard.9.2 A sample size of 5 to 10 L is sufficient to cover theconcentration range of this test method. The volume of thesample shall be accurately determined.9.3 Syringe InjectionFill the syrin
22、ge to the 5 L mark andretract the plunger so that the liquid meniscus is at the 1 Lmark. Note the position of the plunger. Insert the syringeneedle through the inlet septum up to the syringe barrel andallow the furnace to burn all nitrogen bearing residue off thesyringe needle. Reset the detector an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD517620082015STANDARDTESTMETHODFORTOTALCHEMICALLYBOUNDNITROGENINWATERBYPYROLYSISANDCHEMILUMINESCENCEDETECTION

链接地址:http://www.mydoc123.com/p-519070.html