ASTM D1986-1991(2007) Standard Test Method for Determining the Apparent Viscosity of Polyethylene Wax《聚乙烯蜡的表观粘度测量的测试方法》.pdf
《ASTM D1986-1991(2007) Standard Test Method for Determining the Apparent Viscosity of Polyethylene Wax《聚乙烯蜡的表观粘度测量的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1986-1991(2007) Standard Test Method for Determining the Apparent Viscosity of Polyethylene Wax《聚乙烯蜡的表观粘度测量的测试方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1986 91 (Reapproved 2007)Standard Test Method forDetermining the Apparent Viscosity of Polyethylene Wax1This standard is issued under the fixed designation D 1986; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the viscos-ity in centipoise of polyethylene wax using the Brook
3、field LVTor LVF viscometer and thermosel system.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of reg
4、ulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1 Specification for ASTM Liquid-in-Glass Thermometers3. Terminology3.1 Definitions:3.1.1 polyethylene waxpolymerized ethylene with a mo-lecular weight 2,000 to 10,000 and a density of 0.9 to 1.0g/cm3. These polymers can be
5、oxidized or copolymerized butshould have a melt point lower than 140C.3.1.2 viscositythe ratio of shear stress to shear rate. Theviscosity of a liquid is a measure of the internal friction of theliquid in motion. The units of viscosity is the pascal second.For a Newtonian liquid, the viscosity is co
6、nstant at all shearrates. For a non-Newtonian liquid, viscosity will vary depend-ing on shear rate.3.1.3 apparent viscositythe viscosity determined by thistest method and expressed in millipascal seconds. Its valuemay vary with the spindle and rotational speed selectedbecause many waxes are non-Newt
7、onian.4. Significance and Use4.1 This test method is used to determine a physicalproperty of a wax and may determine the utility of the wax, aswell as being a significant quality control test.5. Apparatus5.1 Brookfield Thermosel System, with LVT, LVF, or LVD111 viscometer and SC 4-31 spindle.36. Cal
8、ibration6.1 The viscometer is precalibrated using Newtonian fluidsprovided by the manufacturer. No zero adjustment is providedsince experience has shown that the zero point will not varydue to changes in the spring. The viscometer and spindles areprecision equipment and should be kept from undue sho
9、ck andmishandling. Physical damage to the instrument will oftenreveal itself as erratic or no oscillation of the pointer when theinstrument, with or without the spindle in place, is operated inair. When operating normally, the pointer will be stable andhave free oscillation about the zero point in a
10、ir.6.2 The instrument may be further calibrated using standardreference fluids. Suitable fluids are available in nominalviscosities up to 15 000 mPas at 149C (300F).3The proce-dure for instrument calibration using standard reference fluidsis not encompassed by this test method. Results obtained usin
11、gstandard reference fluids should not deviate from the nominalviscosity by more than 2 %.6.3 The temperature controller of the type recommended forthis procedure is factory calibrated and has control capabilityof 60.5 % of the control point (61.0C at 175C). To furthercheck the controller and further
12、 establish controller settings,use the following procedure. Place a sufficient quantity ofpolyethylene wax in the sample container to permit immersionof the appropriate ASTM thermometer to the proper depth. Donot permit the thermometer bulb to rest on the bottom of thesample container. Suitable ther
13、mometers are shown in Speci-fication E1.6.4 Insert the thermometer through the insulating cover ofthe sample container and hold it in place at the point requiredfor proper immersion depth. Adjust the thermal controller toprovide the desired test temperature. Rotate the thermometerduring temperature
14、reading to minimize the effect of thermalgradients in the sample. Continue temperature readings andcontroller adjustment until minimum deviation from test tem-perature is obtained. Minimum deviation may vary between1This test method is under the jurisdiction ofASTM Committee D21 on Polishesand is th
15、e direct responsibility of Subcommittee D21.02 on Raw Materials.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1991. Last previous edition approved in 2002 as D 1986-91(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD198619912007STANDARDTESTMETHODFORDETERMININGTHEAPPARENTVISCOSITYOFPOLYETHYLENEWAX 聚乙烯 表观 粘度 测量 测试

链接地址:http://www.mydoc123.com/p-510781.html